TEK200SD LHV Power Corporation, TEK200SD Datasheet

no-image

TEK200SD

Manufacturer Part Number
TEK200SD
Description
Linear & Switching Power Supplies AC/DC 200W 24V 8.34A U-CHANNEL
Manufacturer
LHV Power Corporation
Datasheet

Specifications of TEK200SD

Product
Switching
Output Power Rating
150 W
Input Voltage
115 VAC to 230 VAC
Number Of Outputs
1
Output Voltage (channel 1)
24 V
Output Current (channel 1)
6.2 A
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
TEK200 Series
INPUT SPECIFICATIONS:
VOLTAGE
FREQUENCY
INRUSH
CURRENT
PROTECTION
LEAKAGE
HOLD-UP
HARMONICS
OUTPUT SPECIFICATIONS:
ADJUSTMENT RANGE
MINIMUM LOAD
LINE REGULATION
LOAD REGULATION
RIPPLE
SETPOINT ACCURACY
OVER CURRENT
OVER VOLTAGE PROTECTION
STATUS & CONTROL SPECIFICATIONS:
REMOTE ON/OFF
DC OK
AUXILLARY FAN
Product Features:
Universal AC input with Power Factor Correction
Small Size - only 6.80 x 3.80 x 1.50"
100% Burn-in, hi pot tested
Price competitive design
Signals including Enable & DC OK
Auxiliary Fan Output Function
EN61000-3-2 /. IEC100-3-2 Compliant
Worldwide Safety Approvals
EN55022 & FCC Class B Emissions
CE Mark
Universal VAC Input ( 90~264 VAC)
47-63Hz
35A @ 110VAC (Max Cold Start)
4A @ 100 VAC (Max Continous)
Single 5A Fuse / 250 VAC
<1500uA Max @ 264 VAC
20ms Minimum (80% Load)
EN61000-3-2 Class D Compliant
±5% (Minimum)
10% of V1 (Duals Only)
±1% Max over entire input range
±1% maximum
±1% or 50mV pk-k max, whichever is greater (20MHz)
±1%
115-140% (Auto-Recovery)
Latches at >130% of Vnom (V1 only)
High signal enables output VDC
High Signal indicates DC Output is on and within regulation
12V @ 300mA
GENERAL SPECIFICATIONS:
OPERATING TEMPERATURE
STORAGE TEMPERATURE
COOLING
HUMIDITY
VIBRATION
SHOCK
RELIABILITY
EMISSIONS:
EMISSIONS
ELECTROSTATIC DISCHARGE
RADITED SUSCEPTIBILITY
EFT / BURSTS
SURGES
CONDUCTED IMMUNITY
VOLTAGE DIPS
VOLTAGE INTERRUPTIONS
FLUCTUATIONS & FLICKER
SAFETY STANDARDS:
UL /CUL
CSA
TUV
CB REPORT
CE MARK
LHV Power Corporation | 10221 Buena Vista | Santee, CA 92071, USA
Tel: 619 258 7700 | Fax: 619 258 7733 | sales@lhvpower.com
0 ~ +70°C (Derate 2.5% per °C above 50°C)
-40 ~ +85°C
17 cfm Airflow for full load
5-95% (non-condensing)
10-55Hz, 2G, 3Min Period, / 60 min each (3 axes)
20G Peak Acceleration
>100k Hrs (according to MIL-HBK-217F) at 30°C
EN55022 Level B (Conducted)
EN61000-4-2, 4kV Contact / 8kV Air
EN61000-4-3, 26-1000MHz, 10V/M, 80%AM
EN61000-4-4, 2kV
EN61000-4-5, 2kV Earth, 1kV Line-Line
EN61000-4-6, 0.15-800MHz, 10V 80%
EN61000-4-10, 95% Dip & 10ms, 30% Dip & 500ms
EN61000-4-11, 95% reduction, 5ms
EN61000-3-3
60950-1
22.2 No. 60950-1
EN60950-1
IEC 60950-1
Low Voltage Directive
C
UL60950-1
R
US
EN60950-1
TUV Rheinland
H
IEC60950-1
L.V.D.

Related parts for TEK200SD

TEK200SD Summary of contents

Page 1

... VOLTAGE INTERRUPTIONS EN61000-3-3 FLUCTUATIONS & FLICKER SAFETY STANDARDS: UL /CUL 60950-1 CSA 22.2 No. 60950-1 TUV EN60950-1 CB REPORT IEC 60950-1 CE MARK Low Voltage Directive LHV Power Corporation | 10221 Buena Vista | Santee, CA 92071, USA Tel: 619 258 7700 | Fax: 619 258 7733 | sales@lhvpower.com L.V.D. ...

Page 2

... EN61000-4-6, 0.15-800MHz, 10V 80% EN61000-4-10, 95% Dip & 10ms, 30% Dip & 500ms EN61000-4-11, 95% reduction, 5ms EN61000-3-3 60950-1 22.2 No. 60950-1 EN60950-1 IEC 60950-1 Low Voltage Directive LHV Power Corporation | 10221 Buena Vista | Santee, CA 92071, USA Tel: 619 258 7700 | Fax: 619 258 7733 | sales@lhvpower.com ...

Related keywords