Specifications of WDR-120-24

Product
Linear
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
FUNCTION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
AC CURRENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT
OVERLOAD
OVER VOLTAGE
OVER TEMPERATURE
DC OK SIGNAL
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMS IMMUNITY
MTBF
DIMENSION
PACKING
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE, HOLD UP TIME
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
EMI CONDUCTION & RADIATION
120W Single Output Industrial DIN RAIL Power Supply
Note.3
Note.2
WDR-120-12
12V
10A
0 ~ 10A
120W
120mVp-p
12 ~ 15V
2000ms, 70ms, 50ms/400VAC
180 ~ 550VAC
47 ~ 63Hz
105
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
105 ~ 130% rated output power
16 ~ 18V
Protection type : Shut down o/p voltage, re-power on to recover
Relay contact rating(max.) : 30V / 1A resistive
-25 ~ +70
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
Component:
UL508 approved, IEC60950-1 CB approved by SIQ, design refer to GL
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55011 (CISPR11), EN55022 (CISPR22), EN61204-3 Class B
Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN61204-3, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
268Khrs min.
40*125.2*113.5mm (W*H*D)
0.65Kg; 20pcs/14Kg/1.16CUFT
89.5% / 400V
0.55A/400VAC
COLD START 50A
<3.5mA / 530VAC
Protection type : Constant current limiting, recovers automatically after fault condition is removed
1.5%
0.5%
0.5%
0.03%/
5
(12V),110
(0 ~ 50
(Refer to output load derating curve)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting clip:
MIL-HDBK-217F (25 )
I/P-FG:1.5KVAC
254 ~ 780VDC
1.2A/230VAC
5 (24V)
(TSW1) detect on heatsink of
2000ms, 70ms, 10ms/230VAC at full load
O/P-FG:0.5KVAC
WDR-120-24
24V
5A
0 ~ 5A
120W
120mVp-p
24 ~ 29V
31 ~ 37V
91% / 400V
1.0%
0.5%
0.5%
O/P-DC OK:0.5KVAC
power transistor
;
100
W D R - 1 2 0
5 (48V) (TSW1) detect on heatsink of
WDR-120-48
48V
2.5A
0 ~2.5A
120W
150mVp-p
48 ~ 58V
60 ~ 67V
92% / 400V
1.0%
0.5%
0.5%
Compliance to IEC60068-2-6
File Name:WDR-120-SPEC 2010-12-07
s e r i e s
power diode

Related parts for WDR-120-24

WDR-120-24 Summary of contents

Page 1

... EMI CONDUCTION & RADIATION Compliance to EN55011 (CISPR11), EN55022 (CISPR22), EN61204-3 Class B Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN61204-3, EN61000-6-2 (EN50082-2), heavy industry level, criteria A EMS IMMUNITY MTBF 268Khrs min. OTHERS DIMENSION 40*125.2*113.5mm (W*H*D) 0.65Kg; 20pcs/14Kg/1.16CUFT PACKING NOTE WDR-120-24 24V 120W 120mVp 29V 1.5% 1.0% 0.5% 0.5% 0.5% ...

Page 2

... SWITCHING FILTER PWM O.L.P. CONTROL Case No.992B TB2 Terminal Pin No. Assignment (TB1) Pin No. Assignment AC/L2 3 AC/L1 Terminal Pin No. Assignment (TB2) Pin No. Assignment 1,2 Relay Contact 3 DC OUTPUT - OUTPUT RECTIFIERS +V & -V FILTER DETECTION CIRCUIT CURRENT LIMIT O.T.P. O.V.P. File Name:WDR-120-SPEC 2010-12- Unit:mm ...

Page 3

... Single Output Industrial DIN RAIL Power Supply Derating Curve 100 - AMBIENT TEMPERATURE ( ) Static Characteristics 100 Others 90 80 12V (VERTICAL) 180 190 200 250 290 310 360 400 450 490 INPUT VOLTAGE (VAC) 60Hz File Name:WDR-120-SPEC 2010-12- 500 520 550 ...

Related keywords