IC USB PWR CTRLR DUAL 16-QSOP

MIC2012-1PZQS TR

Manufacturer Part Number
MIC2012-1PZQS TR
Description
IC USB PWR CTRLR DUAL 16-QSOP
Manufacturer
Micrel Inc
Datasheet

Specifications of MIC2012-1PZQS TR

Controller Type
USB Power Controller
Interface
USB
Voltage - Supply
4.5 V ~ 5.5 V
Current - Supply
1mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
16-QSOP
Short Circuit Current Limit
0.65 to 1.8A
Input Voltage Range
4.5 to 5.5V
Number Of Switches
Dual
Operating Temp Range
0C to 70C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
16
Package Type
QSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
MIC2012-1PZQSTR
MIC2012-1PZQSTR
Pin Description
January 2005
MIC2012
Pin Number
(MIC2012)
n/a
n/a
n/a
1
2
3
4
5
6
7
8
(MIC2012-1, -2)
Pin Number
4, 6, 7
13, 14
11, 12
9, 10
15
16
1
2
3
5
8
Pin Name
FAULT1
FAULT2
OUT2
OUT1
MAIN
GND
EN1
AUX
EN2
S3#
NC
Pin Function
Fault Status (Output): Internal pull-up or open-drain. Asserted LOW when
Channel is in a thermal shutdown state or overcurrent condition for more
than 5ms. MIC2072 latches this output in its asserted state upon an over-
current condition. Toggling EN1 or removing the load will reset the circuit
breaker latch and deassert FAULT1.
Enable (Input): Channel 1, active-high (–1) or active-low (–2). Toggling this
input also resets the latched output of the MIC2072.
Control (Input): When this input is HIGH, the MAIN inputs are connected to
OUT1 and OUT2 via 100mΩ MOSFET switches. When this input is LOW
the AUX inputs are connected to OUT1 and OUT2 via 500mΩ MOSFET
switches.
Auxiliary 5V Supply (Input): Also used as power supply for internal circuitry.
No Connection: This pin may be connected to other pins without restriction.
Ground
Channel 2 (Output): For MIC2012-1, -2 both pins must be externally con-
nected together.
5V Main Supply (Input): All MAIN inputs must be connected together exter-
nally.
Channel 1 (Output): For MIC2012-1, -2 both pins must be externally con-
nected together.
Enable (Input): Channel 2, active-high (–1) or active-low (–2). Toggling this
input also resets the latched output of the MIC2072.
Fault Status (Output): Internal pull-up or open-drain. Asserted LOW when
Channel 2 is in a thermal shutdown state or overcurrent condition for more
than 5ms. MIC2072 latches this output in its asserted state upon an over-
current condition. Toggling EN2 or removing the load will reset the circuit
breaker latch and deassert FAULT2.
3
MIC2012/2072
Micrel