MIC2010-1PCQS Micrel Inc, MIC2010-1PCQS Datasheet - Page 8

IC USB PWR CTRLR DUAL 16-QSOP

MIC2010-1PCQS

Manufacturer Part Number
MIC2010-1PCQS
Description
IC USB PWR CTRLR DUAL 16-QSOP
Manufacturer
Micrel Inc
Datasheet

Specifications of MIC2010-1PCQS

Controller Type
USB Power Controller
Interface
USB
Voltage - Supply
4.5 V ~ 5.5 V
Current - Supply
1mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
16-QSOP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
MIC2010/2070
off. This time duration will be shortest in the case of a dead
short on the output.
Fault Status Output
The FAULT signal is an active-low output with a weak pull-
up. FAULT is asserted when either an overcurrent or thermal
shutdown condition occurs. In the case of an overcurrent
condition, FAULT will be asserted only after the flag response
delay time, t
asserted only upon valid overcurrent conditions and that
erroneous error reporting is eliminated. The FAULT response
delay time t
shared between both channels it is possible for t
M9999-101104
DLY
DLY
is typically 10ms. Since the delay timer is
, has elapsed. This ensures that FAULT is
(MIC2010-2)
(MIC2070-2)
FAULT
FAULT
V
V
OUT
OUT
EN
EN
Output Resets When Load is Removed
Figure 7. MIC2070 System Timing—
Figure 6. MIC2010 System Timing
DLY
to be
8
extended by an amount equal to the difference between the
occurrence of the over-current event in both channels.
Undervoltage Lockout
Undervoltage lockout (UVLO) prevents the output MOSFET
from turning on until the AUX input exceeds approximately
3.5V. UVLO ensures that the output MOSFETs remain off to
prevent high transient inrush current due to stray or bulk load
capacitance. This helps to ensure that the power supply
voltage regulation is preserved and also prevents possible
damage to sensitive components.
Thermal Shutdown
Load Removed–
Overcurrent Fault
Overcurrent Fault
Output Reset
Reached
January 2005
Micrel