ADM211EARUZ Analog Devices Inc, ADM211EARUZ Datasheet - Page 13

no-image

ADM211EARUZ

Manufacturer Part Number
ADM211EARUZ
Description
IC TXRX RS-232 5V 0.1UF 28-TSSOP
Manufacturer
Analog Devices Inc
Type
Transceiverr
Datasheet

Specifications of ADM211EARUZ

Number Of Drivers/receivers
4/5
Protocol
RS232
Voltage - Supply
4.5 V ~ 5.5 V
Mounting Type
Surface Mount
Package / Case
28-TSSOP
Device Type
Transceiver
Ic Interface Type
RS232
No. Of Drivers
4
Supply Voltage Range
4.5V To 5.5V
Driver Case Style
TSSOP
No. Of Pins
28
Operating Temperature Range
-40°C To +85°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADM211EARUZ
Manufacturer:
Micrel
Quantity:
115
Part Number:
ADM211EARUZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADM211EARUZ-REEL7
Manufacturer:
MEDIATEK
Quantity:
60
Part Number:
ADM211EARUZ-REEL7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
burst of sparks as the relay contacts separate. The voltage
appearing on the line, therefore, consists of a burst of extremely
fast transient impulses. A similar effect occurs when switching
on fluorescent lights.
The fast transient burst test defined in IEC 1000-4-4 simulates
this arcing; its waveform is illustrated in Figure 29. It consists of
a burst of 2.5 kHz to 5 kHz transients repeating at 300 ms
intervals. It is specified for both power and data lines.
Table 9.
Level
1
2
3
4
A simplified circuit diagram of the actual EFT generator is
illustrated in Figure 30.
The transients are coupled onto the signal lines using an EFT
coupling clamp. The clamp is 1 m long and surrounds the cable
completely, providing maximum coupling capacitance (50 pF to
200 pF typical) between the clamp and the cable. High energy
transients are capacitively coupled onto the signal lines. Fast rise
times (5 ns), as specified by the standard, result in very effective
coupling. Because high voltages are coupled onto the signal
lines, this test is very severe. The repetitive transients can often
cause problems where single pulses do not. Destructive latch-up
can be induced due to the high energy content of the transients.
Note that this stress is applied while the interface products are
powered up and are transmitting data. The EFT test applies
hundreds of pulses with higher energy than ESD. Worst-case
transient current on an I/O line can be as high as 40 A.
Test results are classified according to the following:
V
V
Classification 1: Normal performance within speci-
fication limits.
Classification 2: Temporary degradation or loss of
performance that is self recoverable.
5ns
Figure 29. IEC 1000-4-4 Fast Transient Waveform
0.2ms/0.4ms
V Peak (kV)
PSU
0.5
1
2
4
300ms
50ns
V Peak (kV)
I/O
0.25
0.5
1
2
15ms
t
t
ADM206E/ADM207E/ADM208E/ADM211E/ADM213E
Rev. E | Page 13 of 20
ADM2xxE products meet Classification 2 and have been tested
under worst-case conditions using unshielded cables. Data
transmission during the transient condition is corrupted, but it
can resume immediately following the EFT event without user
intervention.
IEC 1000-4-3 RADIATED IMMUNITY
IEC 1000-4-3 (previously IEC 801-3) describes the measure-
ment method and defines the levels of immunity to radiated
electromagnetic fields. It was originally intended to simulate the
electromagnetic fields generated by portable radio transceivers
or any other devices that generate continuous wave-radiated
EM energy. Its scope has since been broadened to include
spurious EM energy that can be radiated from fluorescent
lights, thyristor drives, inductive loads, and other sources.
Testing for immunity involves irradiating the device with an EM
field. There are various methods of achieving this, including use of
anechoic chamber, stripline cell, TEM cell, and GTEM cell. A
stripline cell consists of two parallel plates with an electric field
developed between them. The device under test is placed within
the cell and exposed to the electric field. There are three severity
levels having field strengths ranging from 1 V/m to 10 V/m.
Results are classified in a similar fashion to those for IEC 1000­4­4.
The ADM2xxE family of products easily meets Classification 1 at
the most stringent requirement (Level 3). In fact, field strengths
up to 30 V/m showed no performance degradation, and error-
free data transmission continued even during irradiation.
Classification 3: Temporary degradation or loss of function
or performance that requires operator intervention or
system reset.
Classification 4: Degradation or loss of function that is not
recoverable due to damage.
Classification 1: Normal operation.
Classification 2: Temporary degradation or loss of function
that is self recoverable when the interfering signal is
removed.
Classification 3: Temporary degradation or loss of function
that requires operator intervention or system reset when
the interfering signal is removed.
Classification 4: Degradation or loss of function that is not
recoverable due to damage.
VOLTAGE
SOURCE
HIGH
Figure 30. IEC 1000-4-4 Fast Transient Generator
R
C
C
C
L
Z
S
R
M
C
D
50Ω
OUTPUT