1180-01-1A E-T-A Circuit Protection and Control, 1180-01-1A Datasheet

no-image

1180-01-1A

Manufacturer Part Number
1180-01-1A
Description
Circuit Breaker; Therm; Push; Cur-Rtg 1A; Plug-In; 1 Pole; Vol-Rtg 250/65VAC/VDC
Manufacturer
E-T-A Circuit Protection and Control
Type
Thermalr
Datasheet

Specifications of 1180-01-1A

Actuator Type
Push
Application
For protection of loads in power distribution systems in control cabinets and process control
Brand/series
1180 Series
Current, Rating
1 A
Dielectric Strength
3000
Dimensions
0.961"Lx0.323"Wx1.92"H
Mounting Type
Plug-In
Number Of Poles
1
Resistance, Insulation
100 Megohms (Min.) @ 500 VDC
Standards
CBE Standard EN⁄IEC 60934, VDE Approved, UL Listed
Temperature, Operating, Maximum
60 °C
Temperature, Operating, Minimum
-20 °C
Termination
Blade
Voltage, Rating
250/65 VAC/VDC
Lead Free Status / Rohs Status
RoHS Compliant part
Type: 1180
Dimensions
Internal connection diagrams
Miniaturised single pole thermal circuit breaker with switching function
optional (push-push actuation). Reliable snap-acting and trip-free
mechanism. Approved to CBE standard EN/IEC 60934. S type, TO.
Blade terminals fitting into sockets for rail mounting.
Voltage rating:
Current ratings:
from 0.1 A to 10 A
Number of poles:
single pole
Mounting method:
socket
rail mounting
Terminal design:
blade terminals
Actuation:
push button
Auxiliary contacts:
without auxiliary contacts
Water splash protection:
without water splash protection
Illumination:
without illumination
Typical life:
6,000 operations at 1 x I
3,000 opeations at 1 x I
500 operations at 2 x I
Interrupting capacity I
0.1...5 A: 6 x I
6...10 A: 8 x I
Approvals:
VDE, UL, UL Canada
AC 250 V
DC 65 V
UL, UL Canada: AC 250 V
UL, UL Canada: DC 72 V
N
N
N
N
cn
N
inductive)
(inductive)
:
(resistive)

Related parts for 1180-01-1A

1180-01-1A Summary of contents

Page 1

... Type: 1180 Dimensions Internal connection diagrams Miniaturised single pole thermal circuit breaker with switching function optional (push-push actuation). Reliable snap-acting and trip-free mechanism. Approved to CBE standard EN/IEC 60934. S type, TO. Blade terminals fitting into sockets for rail mounting. Voltage rating: AC 250 UL, UL Canada: AC 250 V ...

Page 2

... Versions 01 with switching function, without label 02 reset function only, without label Current rating range 0.1...10 A 1180 - ordering example Standard current ratings and typical internal resistance values Current Internal Current rating (A) resistance (Ω) rating (A) ...

Page 3

... Thermal Overcurrent Circuit Breaker 1180-... Dimensions 24.4 .961 1 5.2 .205 14.5 .571 16.6 .654 18.2 .717 19,8 .780 slot for fitting labels (see accessory 1) Internal connection diagram Shock directions Typical time/current characteristics at +23 °C7+73.4 °F 1.1 .043 0.6 .024 3.1 .122 3 ...

Related keywords