PW300MA0012F01 SL Power ( Ault / Condor ), PW300MA0012F01 Datasheet

no-image

PW300MA0012F01

Manufacturer Part Number
PW300MA0012F01
Description
Power Supply, Wall plug, 50 Watts, +5V@5 Amps, +12V@4 Amps, -12@0.5 Amps
Manufacturer
SL Power ( Ault / Condor )
Datasheet

Specifications of PW300MA0012F01

Brand/series
PW300 Universal Series
Configuration
Wall Plug
Number Of Outputs
3
Operation
Switching
Output
-12 VDC @ 0.5 A, +5 VDC @ 5 A, +12 VDC @ 4 A
Power, Output
50 W
Primary Type
AC-DC
Voltage, Input
100 to 250 VAC
Voltage, Output
-12, +5, +12 VDC
Lead Free Status / Rohs Status
RoHS Compliant part
OUTPUT
Model
PW300KA0012F01
INPUT
Protection
Cord and Connectors
Voltage
Line Frequency
Current
Configuration
Combined Line and Load
Ripple
Transient Response
Holdup Time
Protection
Voltage Regulation
Excluding Cord
Voltage
+5VDC
+12VDC
-12VDC
Min.
Current
0A
0A
0A
AULT SPECIFICATION
100-250VAC -10%, +6%
47-63 Hz
1.3A Max. at 100VAC Input
Internal primary current fuse, Inrush limiting
Overcurrent and short circuit protected
In Case IEC320 with Ground
+5VDC: +1% Combined +5,+12 Output of
>0.6A
+12VDC: +5% -5% Combined +5, +12
Output of >0.6A
-12VDC: +6% Combined +5, +12 Output of
>0.6A
+5: 50mV p-p Max combined +5, +12
Output >0.6A
+12: 100mV p-p Max combined +5, +12
Output >0.6A
--12: 100mV p-p Max combined +5, +12
Output >0.6A
0.5mSec for 50% load change typical
20mSec @ 120VAC; 120mSec @ 240VAC
Foldback overcurrent protection on all
outputs
Short circuit protection on all outputs
OVP 6.8V Max on +5VDC
3 ft., 5 Conductor, 18 AWG, Ault #12
Connector
Other Connectors are also available
PW300 Universal Series
Max.
Current
5.0A
4.0A
0.5A
Max.
Watts
25.0
24.0
6.0
Max.
Power
50 Watts

Related parts for PW300MA0012F01

PW300MA0012F01 Summary of contents

Page 1

INPUT Voltage Line Frequency Current Protection Configuration OUTPUT Model Voltage PW300KA0012F01 +5VDC +12VDC -12VDC Combined Line and Load Voltage Regulation Excluding Cord Ripple Transient Response Holdup Time Protection Cord and Connectors AULT SPECIFICATION PW300 Universal Series 100-250VAC -10%, +6% 47-63 ...

Page 2

ELECTRICAL Topology Dielectric Withstand Safety Spacings Leakage Current Efficiency EMI CE SAFETY APPROVALS ENVIRONMENTAL Operating Temperature Storage Temperature Relative Humidity Altitude Cooling MECHANICAL Case and Dimensions Case Material Weight WARRANTY Switching - Fixed Frequency Flyback 3000VAC, 4250VDC Primary - Secondary ...

Related keywords