MSO-0011P-012 NCC, MSO-0011P-012 Datasheet - Page 96

no-image

MSO-0011P-012

Manufacturer Part Number
MSO-0011P-012
Description
Socket, Relay; 11 Pin Octal, ID# SR3P-06
Manufacturer
NCC
Type
Octalr
Datasheet

Specifications of MSO-0011P-012

Number Of Contacts
11
Time Range
0.05 Sec. to 999 Min.
Output Rating
10 A @ 240 VAC Max.; 100 mA @ 5 VDC Min.
Operating Temperature
–23°C to +55°C
4-24
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com
SPECIFICATIONS
INPUTS
Voltages: 105-135 VAC, 50/60 Hz; 210-270 VAC,
50/60 Hz
Switched Inputs:
Alarm Input Open Circuit Voltage: 10 VDC
Alarm Input Short Circuit Current: 13 mA
#1: Display 1 Alarm: Status LED Auxiliary Alarms
#2: Display 2 Alarm: Status LED Auxiliary Alarms
OUTPUTS
Alarm Output
Type: 1-Form A (SPST) relay contact
Rating: 3 A at 120/240 VAC
Display: 2 line x 8 character; alpha-numeric
vacuum fluorescent, .3” high
Status LEDs:
Quantity: 12
Type: Tri-Color; Red-Fault, Yellow-Alarm acknowl-
edged, Green-Normal
Status LED Nomenclature:
Serial Communications: Null modem type con-
nection required between display and terminal or
PC
Type: RS232
Mode: 9600 Baud, 8-Data Bits,1-Stop Bit, No
Parity
Function: Dedicated For Communication with an
ANSI type VT100 Terminal
Connector: 9-pin male IBM compatible D-SUB
connector null modem type connection required
between display and terminal or PC.
Network Connection:
Type: 2 wire twisted pair
Transmission Line: 2 wire twisted pair (Belden
85102 or 8471 or equiv. recommended)
Termination: 50 or 100 ohm, jumper selectable
resistor
Network Connection Device: Echelon FTT-10A
Transceiver
ENVIRONMENTAL
Operating Temperature: -40°C to 65°C
Storage Temperature: -40°C to 70°C
Humidity: 90% non-condensing
Protection: Conformal coat for humidity and
vibration
Contact Factory for Additional Information
Free Topology: 50 ohm termination on only one
end of the network bus. Remove jumper on all
other bussed units.; Node-to-Node distance
1640.5 ft. max.; Bus Length 1640.5 ft max.
Double Terminated: 100 ohm termination on
each end of the network bus; remove jumper on
all other bussed units; bus length 8858.3 ft max.
dP Alarm
Auxiliary Alarms
Temperature Alarm
Emission/Aux 1 Alarm
Air Flow/Aux 2 Alarm
Comp. Air/Aux3 Alarm
DUST COLLECTOR CONTROLS
Solenoid Alarm
Fan/Alarm 1
Network Status
Airlock/Aux4 Alarm
Hopper/Aux5 Alarm
Diaphragm Fault
Input 2
Input 2
Remote Alarm
Remote Alarm
Input Voltage
L1
L2
To PC or Terminal
RS-232 Null Modem Cable
Alarm File Output Format:
IDENTxxx, Year, Month, Day, Hour, Differential
Pressure, Emissions, Airflow, Manifold Pressure,
Bag Temperature, Temperature Probe Failure, Bad
Solenoid, Differential Pressure too Hi/Low, One hour
warmup failure, 5 cleaning cycle alarm, External
alarm input #1, External alarm input #2, External
alarm input #3, External alarm input #4, Triac is
shorted on, 0, 0, 0, 0, 0, 0, High emission, High or
Low airflow, Manifold pressure current loop out of
range, Manifold pressure too low before firing of
the solenoid, Manifold pressure did not drop when
a solenoid fired, High bag temperature alarm, High
hopper alarm, Airlock fault, 0, Bag temperature probe
open, Communication fault, Timer fail, 0, 0, 0, 0, Last
solenoid that fired before the alarm, Solenoid number
that did not fire, Solenoid number which is stuck on,
Last solenoid that fired before alarm input #1, Last
solenoid that fired before alarm input #2, Last sole-
noid that fired before alarm input #3, Last solenoid
that fired before alarm input #4.
File Output Format:
xxx, xx, xx, xx, xx, xxx, xxxx, xxxxxxx, xxxx, xxxx, x,
x, x, x, x, x, x, x, x, x, 0, 0, 0, 0, 0, 0, x, x, x, x, x, x,
x, x, 0, x, x, 0, 0, 0, 0, 0, xxx, xxx, xxx, xxx, xxx, xxx,
xxx, CR, LF
Short and Long Term Memory File Output Format:
IDENTxxx(1-255), Year (last 2 digits), Month (1-12),
Day(1-31), Hour(0-23), Differential Pressure (in. H
Emissions or AUX1 (percentage), Airflow (SCFM) or
AUX2 (percentage), Manifold Pressure (psi) or AUX3
(percentage), Bag Temperature (°F), Number of
Solenoids that fired.
File Output Format:
xxx, xx, xx, xx, xx, xxx, xxxx, xxxxxxx, xxxx, xxxx,
xxxxx, CR, LF
Relay Output
Remote Alarm
ALARM
TERMINATIO N
50
100
Alarm Voltage
Source
Network
Connection
to Enhanced
Timer Network
2