H3CR-F AC100-240 Omron Automation, H3CR-F AC100-240 Datasheet

no-image

H3CR-F AC100-240

Manufacturer Part Number
H3CR-F AC100-240
Description
Timer; Repeat Cycle; 0.05s-30h; E-Mech; Ctrl-V 100-240AC; 5A@250VAC/30VDC; 11-PinOctal
Manufacturer
Omron Automation
Datasheet

Specifications of H3CR-F AC100-240

Current, Rating
5 A
Function
Timing
Mounting Type
Socket
Number Of Pins
11
Relay Type
Electro Mechanical
Repeatability
±0.3% (Max.)
Standards
UL, CSA, CE
Temperature, Operating, Maximum
+55 °C
Temperature, Operating, Minimum
-10 °C
Termination
Plug-In
Timer Type
Repeat Cycle
Timing Range
0.05s-30h
Voltage, Control
100-240 VAC
Voltage, Rating
250 VAC⁄30 VDC VAC⁄VDC
Timing Functions
4 Function
6 Function
ON-Delay, Repeat Cycle ON or OFF, Signal ON/OFF, Signal OFF, Interval (11-Pin)
Timing Ranges
Multi-Function
Lead Free Status / Rohs Status
RoHS Compliant part
DIN 48 × 48-mm Twin Timers
• Wide power supply ranges of 100 to 240 VAC and 48 to
• ON- and OFF-times can be set independently and so
• Fourteen time ranges from 0.05 s to 30 h or from 1.2 s to 300 h
• Models with a flicker ON start or flicker OFF start are available.
• Easy sequence checks through instantaneous outputs for a
• Length, when panel-mounted with a Socket, of 80 mm or less.
• 11-pin and 8-pin models are available.
Model Number Structure
■ Model Number Legend
Ordering Information
■ List of Models
1. Classification
F:
2. Configuration
None: 11-pin socket
8:
Note: Specify both the model number and supply voltage when ordering.
Flicker OFF
start
Flicker ON start 100 to 240 VAC
H3CR - F @ @ - @ @
125 VDC respectively.
combinations of long ON- or OFF-time and short OFF- or ON-
time settings are possible.
depending on the model to be used.
zero set value at any time range.
Solid-state Twin Timers
H3CR-F
Operating
modes
Example: H3CR-F 100-240AC
Twin timers
8-pin socket
1 2
100 to 240 VAC
24 VAC/DC
12 VDC
48 to 125 VDC
24 VAC/DC
12 VDC
48 to 125 VDC
3
voltage
Supply
4
5
H3CR-F 100-240AC
H3CR-F 24AC/DC
H3CR-F 12DC
H3CR-F 48-125DC
H3CR-FN 100-240AC
H3CR-FN 24AC/DC
H3CR-FN 12DC
H3CR-FN 48-125DC
3. Twin Timer Mode
None: Flicker OFF start
N:
4. Time Range
None: 0.05 s to 30 h models
300:
11-pin models
Supply voltage
Flicker ON start
1.2 s to 300 h models
0.05 s to 30 h models
H3CR-F8 100-240AC
H3CR-F8 24AC/DC
H3CR-F8 12DC
H3CR-F8 48-125DC
H3CR-F8N 100-240AC
H3CR-F8N 24AC/DC
H3CR-F8N 12DC
H3CR-F8N 48-125DC
8-pin models
5. Supply Voltage
100-240AC: 100 to 240 VAC
24AC/DC:
12DC:
48-125DC: 48 to 125 VDC
H3CR-F-300 100-240AC
H3CR-F-300 24AC/DC
H3CR-F-300 12DC
H3CR-F-300 48-125DC
H3CR-FN-300 100-240AC
H3CR-FN-300 24AC/DC
H3CR-FN-300 12DC
H3CR-FN-300 48-125DC
11-pin models
24 VAC/VDC
12 VDC
1.2 s to 300 h models
H3CR-F8-300 100-240AC
H3CR-F8-300 24AC/DC
H3CR-F8-300 12DC
H3CR-F8-300 48-125DC
H3CR-F8N-300 100-240AC
H3CR-F8N-300 24AC/DC
H3CR-F8N-300 12DC
H3CR-F8N-300 48-125DC
CSM_H3CR-F_DS_E_1_2
8-pin models
1

Related parts for H3CR-F AC100-240

H3CR-F AC100-240 Summary of contents

Page 1

... Models with a flicker ON start or flicker OFF start are available. • Easy sequence checks through instantaneous outputs for a zero set value at any time range. • Length, when panel-mounted with a Socket less. • 11-pin and 8-pin models are available. Model Number Structure ■ Model Number Legend H3CR - Classification 3. Twin Timer Mode ...

Page 2

... P3GA-11 with Y92A-48G (See note 1) Y92H-7 Y92H-8 H3CR-F8 H3CR-FN Flicker ON start 8-pin 11-pin ×10 s (10 sec) min (min) 1 0. 120 1 300 ×10 min (10 min) h (hrs) 1 0. 120 1 300 H3CR-F Models H3CR-F8N 8-pin h (hrs) ×10 h (10 hrs) 1 120 30 to 300 2 ...

Page 3

... EN61812-1 EN55011 Group 1 class A EN55011 Group 1 class A EN61812-1 IEC61000-4- contact discharge (level air discharge (level 3) IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level (0. MHz) (level 3) IEC61000-4- power-line (level I/O signal-line (level 4) IEC61000-4- line to line (level line to ground (level 3) H3CR-F 3 ...

Page 4

... The minimum applicable load VDC (failure level: P). Zero setting OFF indicator detection circuit Indicator circuit ROM RAM Clock One-chip microcomputer H3CR-F H3CR-FN H3CR-F-300 H3CR-FN-300 Power supply Note: Leave terminals 5, 6, and 7 open. Do not use them as relay terminals. H3CR-F Output circuit Time range/unit selectors (+)(~) 4 ...

Page 5

... ON-time setting knob (with orange pointer) For ON-time setting OFF-time setting knob (with green pointer) For OFF-time setting ON-time unit display window ON-time unit selector (select one from sec min, and hrs, or from min, hrs, and 10 h) H3CR-F 0.1 s min OFF OFF 0.1 s min. t ...

Page 6

... R1.3 17 dia dia. R1.3 Dimensions with Back Connecting Socket P3G-08/P3GA-11 81.5 17.4 80 H3CR-F8 H3CR-F8N 90.0 H3CR-F H3CR-FN P3GA-11 Y92F-30 (When * Y92A-48G 2.3 P2CF-08 mounted) P2CF-08-E H3CR-F 66.6 52.3 0.7 6 44.8 × 44.8 11 pins 66.6 0.7 5.7 52.3 6 44.8 × ...

Page 7

... A time range (1.2, 3, 12, or 30/2. for H3CR-A@-301) is selected with the time range selector at the lower left corner of the front panel, and the selected time range appears (in the window at the lower right part) within the plastic frame of the time setting knob ...

Page 8

... No time unit selector is available. When ordering the H3CR-H, specify S (for the second unit (for the minute unit) for your H3CR-H. Setting of Time Use the time setting knob to set the desired time. ...

Page 9

... Note: All units are in millimeters unless otherwise indicated. Flush Mounting Adaptor Y92F-30 Note: The adapters for two or more timers mounted in a vertical line are different in orientation from those mounted in a horizontal line. N can be obtained as follows (n: the number of H3CR models arranged side by side) +1 Without a Cover (48n - 2. With the Protective Cover (51n - 5 ...

Page 10

... Terminal Arrangement/ Internal Connections 35.4 (Top View) 31.2 max. 7.8 5 4.5 3 1.2 35.4 Two, 4.5 dia. holes 30 31.2 max. H3CR Surface Mounting Holes Two, 4.5 dia. or two, M4 40±0.2 Surface Mounting Holes Two, 4.5 dia. or two, M4 40±0.2 4 ...

Page 11

... Internal Connections (Bottom View) 25.6 4.5 6.2 16.3 Twelve, 6.4 dia. holes 47.7 × 47.7 34 16.5 24.6 27.6 47.4 PFP-100N2 7.3±0.15 4.5 27±0.15 35±0 1,000 Spacer 10 PFP-S 6.2 1.8 1 35.5 35.3 1.8 1.3 4.8 H3CR 48 × 35±0 34.8 44.3 16.5 5 ...

Page 12

... Do not set the selectors midway between notches, otherwise the Timer may break or malfunction. Do not use H3CR-A models (except for H3CR-A@S) in flicker mode, or H3CR-F models at the lowest selector setting. Doing so may result in damage to contacts. Power Supplies A DC power supply can be connected if its ripple factor is 20% or less and the mean voltage is within the rated operating voltage range of the Timer ...

Page 13

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a ...