H5CX-AD-N AC24/DC12-24 Omron Automation, H5CX-AD-N AC24/DC12-24 Datasheet - Page 23

no-image

H5CX-AD-N AC24/DC12-24

Manufacturer Part Number
H5CX-AD-N AC24/DC12-24
Description
Relay; E-Mech; Timing; Multi-Function; Cur-Rtg 5A; Ctrl-V 24/12-24AC/DC; Screw; 11 Pin
Manufacturer
Omron Automation
Type
Timerr
Datasheet

Specifications of H5CX-AD-N AC24/DC12-24

Brand/series
H5CX
Connection Type
Screw Terminals
Contact Form
5 A at 250VAC/30 VDC
Dimensions
58H x 48W x 98.5D
Display Type
7 Segment LCD
Function
Multifunction Digital Timer
Input Type
Signal, Reset and Gate
Ip Rating
IP66
Mounting Type
Flush, Surface or Din Rail
Number Of Inputs
3
Number Of Outputs
1
Output Type
SPDT
Primary Type
Digital Timer
Voltage, Supply
12-24 VDC/24 VAC
Models with Instantaneous Contact Outputs
Note: H5CX-L8E@-N Precautions
Instantaneous
Instantaneous
Mode S: Stopwatch (Timer resets when power comes ON.)
Basic operation
The signal starts and stops timing.
The display is held and timing is continued if the reset
or gate input is received during timing operation.
The timer resets if the reset or gate input is received
when the timing operation is stopped.
Note: Output is instantaneous when setting is 0.
Mode A-2: Power ON delay (Timer resets when power comes ON.)
Basic operation
The Timer starts when the power comes ON or when
the reset input goes OFF.
Note: Output is instantaneous when setting is 0.
Mode b: Repeat cycle 1 (Timer resets when power comes ON.)
Basic operation
The Timer starts when the power comes ON or when
the reset input goes OFF.
Note: Normal output operation will not be possible if
(for elapsed
Start signal
Gate/Reset
Time-limit
Time-limit
Display
Power
Power
Power
output
output
output
output
Set the Timer’s set value before using the Timer in a self-holding circuit.
input
time)
the set time is too short.
Set the value to at least 100 ms.
t (time)
Timing
t (time)
Timing
*
*
RST
flashes
t (time)
t (time)
Detailed operation
Detailed operation
Detailed operation
Sustained Output
One-shot Output
Instantaneous
Instantaneous
contacts, NC
contacts, NO
contacts, NC
contacts, NO
Gate/Reset
Reset Key
Start signal
Time-limit
Time-limit
UP
DOWN
Instantaneous
Instantaneous
contacts, NO
contacts, NO
contacts, NO
contacts, NC
contacts, NC
contacts, NC
Set time
Set time
Power
Output
Power
Reset Key
Time-limit
Time-limit
Time-limit
Time-limit
9999
Power
0
0
t-a
t = Set time, Rt = Reset time (0.5 s min.), t – a < t (Indicates the time is less than the set time.)
t-a
t = Set time, Rt = Reset time (0.5 s min.), t – a < t (Indicates the time is less than the set time.)
t
t
t
t
t-a
Rt
Either one-shot output or sustained output can be selected.
Rt
t
t
t
H5CX-A@-N/-L@-N
t
t-a
t-a
t-a
Rt
Rt
t-a
t-a
Timer
23