F-341X Triad Magnetics, F-341X Datasheet

no-image

F-341X

Manufacturer Part Number
F-341X
Description
Transformer; Chassis; Pri:115/230V; Sec:25.2VCT; Sec:2A; Lead; 60Hz; 4In.In.W; 2-19/32In
Manufacturer
Triad Magnetics
Type
Powerr
Datasheet

Specifications of F-341X

Brand/series
F Series
Configuration
Bobbin
Current, Secondary
2 A
Dimensions
4"W×2-19/32"H×2-1/4"D
Frequency
60 Hz
Length, Lead
7 "
Mounting Hole Centers
3.562 "
Mounting Type
Panel/Chassis
Number Of Outlets
2
Phase
1
Standards
UL
Temperature, Operating
+35 °C
Termination
Leadwires
Voltage, Primary
115/230 VAC
Voltage, Secondary
25.2 (C.T.) VAC
Weight
2.2 lbs.
Leaded Process Compatible
Yes
Transformer Type
Power
Rohs Compliant
Yes
Current Rating
2A
Lead Free Status / Rohs Status
RoHS Compliant part
F-341X
Electrical Specifications (@25C)
1. Maximum Power: 50.4 VA
2. Primary:
3. Secondary: 25.2VCT @ 2.00 Amps
4. Voltage Regulation: 10 % TYP @ full load to no load
5. Temperature Rise: 35C TYP (45C MAX allowed)
Description:
The F-341X is part of a series which has a long history of reliable service in the
field, made from a proven design and constructed with UL recognized materials.
Construction:
Wound on a single channel nylon bobbin. Materials are UL recognized, Class B
(130º C) rated.
Safety:
These products are 100% hipot tested with an insulation of 1500V between
primary and secondary windings as well as between the primary / secondary
windings and the core.
Dimensions:
Mounting Hole Diameter: .187 in
Lead length: 7.0 inches + 1 inch
Weight: 2.20 lbs
Schematic:
Primary:
Series: BLK to BLK/GRN, Jumper YEL/BLK to RED/BLK
Parallel: BLK to YEL/BLK, Jumper BLK to RED/BLK and YEL/BLK to BLK/GRN
Secondary: Green to Green
RoHS Compliance:
products meet the requirements of 2002/95/EC, known as the RoHS initiative.
2.593
A
4.00
Series: 230V 50/60 Hz
Parallel: 115V 50/60 Hz
B
2.250
C
As of manufacturing date February 2005, all standard
Units: In inches
3.562
D
BLK
YEL/BLK
RED/BLK
BLK/GRN
GRN
GRN/YEL
GRN
P
Chassis Mount: Single Secondary
O W E R
T
R A N S F O R M E R
BLK/GRN
RED/BLK
BLK
YEL/BLK
B
D
A
C
GRN/YEL
GRN
GRN

Related parts for F-341X

F-341X Summary of contents

Page 1

... Voltage Regulation TYP @ full load to no load 5. Temperature Rise: 35C TYP (45C MAX allowed) Description: The F-341X is part of a series which has a long history of reliable service in the field, made from a proven design and constructed with UL recognized materials. Construction: Wound on a single channel nylon bobbin. Materials are UL recognized, Class B (130º ...

Page 2

... Triad offers a full choice of power supply transformers for direct use or in transformer, rectifier, or filter circuits. Other available secondary voltages include control, filament and low level signaling in standard values. The transformers are single primary with single and multiple secondaries in standard size and weight configurations. ...

Page 3

... CT 1.000 F-255X 20.0 CT 2.000 F-256U 20.0 CT 4.000 F F-257U 20.0 CT 6.000 F-258U 20.0 CT 8.000 F-259U 20.0 CT 10.000 F-115X 24.0 CT 0.085 F-3115X 24.0 CT 0.085 F-116X 24.0 CT 0.200 F-3116X 24.0 CT 0.200 F-117X 24.0 CT 0.400 F-3117X 24.0 CT 0.400 F-118X 24.0 CT 0.700 G F-3118X 24.0 CT 0.700 F-45X# 24 ...

Page 4

... Type Secondary Section No. Volts Amps F-57X 25.2 CT 1.000 F-357X 25.2 CT 1.000 A F-41X# 25.2 CT 2.000 F-341X 25.2 CT 2.000 F-56X 25.2 CT 2.800 F-119X 26.8 CT 0.150 F-40X# 26.8 CT 1.000 B F-340X 26.8 CT 1.000 F-55X 26.8 CT 1.700 F-355X 26.8 CT 1.700 F-122X 28.0 CT 0.175 F-124X 28.0 CT ...

Related keywords