F-344X Triad Magnetics, F-344X Datasheet

no-image

F-344X

Manufacturer Part Number
F-344X
Description
Transformer; Chassis; Pri:115/230V; Sec:12.6VCT; Sec:2A; Lead; 50/60Hz; 3-5/16In.In.W
Manufacturer
Triad Magnetics
Type
Powerr
Datasheet

Specifications of F-344X

Brand/series
F Series
Configuration
Bobbin
Current, Secondary
2 A
Dimensions
3-5/16"W×1-15/16"H×2"D
Frequency
50/60 Hz
Length, Lead
7 "
Mounting Hole Centers
2.812 "
Mounting Type
Panel/Chassis
Number Of Outlets
2
Phase
1
Standards
UL
Temperature, Operating
+35 °C
Termination
Leadwires
Voltage, Primary
115/230 VAC
Voltage, Secondary
12.6 (C.T.) VAC
Weight
1.25 lbs.
Lead Free Status / Rohs Status
RoHS Compliant part
F-344X
Electrical Specifications (@25C)
1. Maximum Power: 25.2 VA
2. Primary:
3. Secondary: 12.6VCT @ 2.0 Amps
4. Voltage Regulation: 15 % TYP @ full load to no load
5. Temperature Rise: 35C TYP (45C MAX allowed)
Description:
The F-344X is part of a series which has a long history of reliable service in the
field, made from a proven design and constructed with UL recognized materials.
Construction:
Wound on a single channel nylon bobbin. Materials are UL recognized, Class B
(130º C) rated.
Safety:
These products are 100% hipot tested with an insulation of 1500V between
primary and secondary windings as well as between the primary / secondary
windings and the core.
Dimensions:
Mounting Hole Diameter: .187 in
Lead length: 7.0 inches + 1 inch
Weight: 1.25 lbs
Schematic:
Primary:
Series: BLK to BLK/GRN, Jumper YEL/BLK to RED/BLK
Parallel: BLK to YEL/BLK, Jumper BLK to RED/BLK and YEL/BLK to BLK/GRN
Secondary: Green to Green
RoHS Compliance:
products meet the requirements of 2002/95/EC, known as the RoHS initiative.
1.937
A
3.312
Series: 230V 50/60 Hz
Parallel: 115V 50/60 Hz
B
2.00
C
As of manufacturing date February 2005, all standard
Units: In inches
2.812
D
BLK
YEL/BLK
RED/BLK
BLK/GRN
GRN
GRN/YEL
GRN
P
Chassis Mount: Single Secondary
O W E R
T
R A N S F O R M E R
BLK/GRN
RED/BLK
BLK
YEL/BLK
B
D
A
C
GRN/YEL
GRN
GRN

Related parts for F-344X

F-344X Summary of contents

Page 1

... Voltage Regulation TYP @ full load to no load 5. Temperature Rise: 35C TYP (45C MAX allowed) Description: The F-344X is part of a series which has a long history of reliable service in the field, made from a proven design and constructed with UL recognized materials. Construction: Wound on a single channel nylon bobbin. Materials are UL recognized, Class B (130º ...

Page 2

... Triad offers a full choice of power supply transformers for direct use or in transformer, rectifier, or filter circuits. Other available secondary voltages include control, filament and low level signaling in standard values. The transformers are single primary with single and multiple secondaries in standard size and weight configurations. ...

Page 3

... F-221U# 12.0 8.000 F-29U† 12 11 10.0 CT F-70X 12.6 CT 1.000 F-25X 12.6 CT 1.500 F-325X 12.6 CT 1.500 F-44X# 12.6 CT 2.000 F-344X 12.6 CT 2.000 D F-26X# 12.6 CT 2.500 F-326X 12.6 CT 2.500 F-224X# 12.6 3.000 F-225X# 12.6 4.000 F-3181U 12.6 CT 4.000 F-182U 12 ...

Page 4

... Wingdings may be connected in series to obtain their combined voltage when properly phased. Current will be equal to the current of the lowest winding. Example: Two 6.3 V windings @ 2A in series would be 12 2A. Wingdings may also be connected in parallel to obtain combined current. Example: Two 6.3 V windings @ 2A in parallel would be 6 ...

Related keywords