1626-3-5A E-T-A Circuit Protection and Control, 1626-3-5A Datasheet

no-image

1626-3-5A

Manufacturer Part Number
1626-3-5A
Description
CIRCUIT BREAKER; THERM; MINI CBE; TYPE 3 MANUAL RESET; CUR-RTG 5A ; 24VDC
Manufacturer
E-T-A Circuit Protection and Control
Type
Thermal Automotiver
Datasheet

Specifications of 1626-3-5A

Actuator Type
Press-to-Reset
Brand/series
1626 Series
Current, Rating
5 A
Mounting Type
Socket
Termination
Blade
Lead Free Status / Rohs Status
RoHS Compliant part
Single pole, thermal miniaturised circuit breaker designed for automotive
applications. Fits into fuse blocks designed to ISO 8820-3, Type F.
Automatic reset (for DC 12 V only) and open circuit (modified reset to
SAE) version optional. Open circuit version ensures contacts staying
open as long as power is on. The circuit breaker will reset after the
load is removed. Particularly suitable for installation in inaccessible
locations.
Current ratings correspond to those of blade fuses. Clear colour coding
of the ratings: blade fuse and circuit breaker of the same colour have
the same rating.
Protection of electrical systems of passenger cars, trucks, buses,
watercraft, extra low voltage wiring systems.
Type No.
1626
1626 - 1 - ... - 10 A
Current
rating (A)
5
7,5
10
15
20
25
30
010409
Description
Typical applications
Ordering information
Current ratings, typical voltage drop values and colour coding
single pole thermal Mini-CBE
Version, according to SAE J553
1
2
3
3F
3H
type 1, DC 12 V automatic reset
type 2, modified reset (not yet available)
type 3, DC 24 V with reset button
type 3, DC 24 V with trip free mechanism (not yet available)
type 3*, DC 24 V with manual release button
Voltage rating
...
1
2
standard
12 V – only for type 2
24 V – only for type 2
Current ratings
5
7,5
Thermal automotive Mini-CBE 1626-...
ordering example
Voltage
drop (mV)
< 150
< 150
< 150
< 150
< 150
< 150
< 150
10
15
20
25
Housing cap colour
light brown
brown
red
blue
yellow
white
light green
30 A
www.e-t-a.com
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications without
notice is reserved. Product markings may not be exactly as the ordering codes. Errors and
omissions excepted.
Max. voltage rating
Ultimate short-circuit
breaking capacity
Shock
Corrosion
Humidity
Voltage rating
Current ratings
Service short-circuit
breaking capacity
Ambient temperature
Reset period for 1626-1
(at 23 °C)
Reset period for 1626-2
(at 23 °C)
Degree of protection
(IEC 60529)
Mass
It is good practice to switch off the vehicle’s ignition system before
re-setting the circuit breaker. Free travel of the actuator must be
ensured.
Vibration
Technical data
1626-1
1626-2-2, 1626-3, 1626-3F, 1626-3H:
DC 12 V, DC 24 V
1626-1, 1626-2-1: DC 12 V
1626-2-2, 1626-3, 1626-3F, 1626-3H:
DC 32 V
1626-1, 1626-2-1: DC 16 V
5...30 A
300 operations at ≤ 50 A
-40...85 °C (-40 … +185°F)
≤ 15 s
after 5 sec at rated voltage < 35 s
operating area IP40 (-3)
operating area IP50 (-1, -2)
terminal area IP00
≥ 3 break operations at 150 A, or
≥ 1 break operation at 2,000 A
10 g (57-500 Hz), ± 0,38 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
50 g (11 ms)
to IEC 60068-2-27, test Ea
96 hrs in 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hrs in 95 % RH,
to IEC 60068-2-78, test Cab
approx. 3 g
1626-3
1626-3H
1

Related parts for 1626-3-5A

1626-3-5A Summary of contents

Page 1

... with manual release button Voltage rating ... standard – only for type – only for type 2 Current ratings 5 7 1626 - 1 - ... - 10 A ordering example Current ratings, typical voltage drop values and colour coding Current Voltage rating (A) drop (mV) 5 < 150 7,5 < 150 10 < 150 15 < 150 20 < ...

Page 2

... Thermal automotive Mini-CBE 1626-... Dimensions 1626-1 13.3 .512 GERMANY 4.5 .177 2.8 2.8 .110 10.9 .429 12.7 .500 1626-3 13.3 3.5 .524 .138 2 1.8 .079 .071 GERMANY 1626-3H 13.3 .524 4.8 3.5 .189 .138 GERMANY 2 Internal connection diagrams 1626-1 1626-2 7 .275 ...