423-12-60FPM ARTISAN CONTROLS, 423-12-60FPM Datasheet

no-image

423-12-60FPM

Manufacturer Part Number
423-12-60FPM
Description
Relay; SSR; Timing; Flasher; Cur-Rtg 0-1A; Ctrl-V 12DC; Quick Connect; 60FPM
Manufacturer
ARTISAN CONTROLS
Datasheet

Specifications of 423-12-60FPM

Current, Rating
1 A
Depth
0.76 in.
Duty Cycle
50%
Function
Timing
Length
2.65 in.
Relay Type
Solid State
Temperature, Operating, Maximum
85 °C
Temperature, Operating, Minimum
-20 °C
Termination
Quick Connect
Timer Type
Flasher
Timing Range
60 FPM
Voltage, Control
12 VDC
Width
1.7 in.
Lead Free Status / Rohs Status
RoHS Compliant part
Mechanical & Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Timing Diagram . . . . . . . . . . . . . . .
OPEN
Alternate Wiring
-
+
ON
Operating Voltage
ON
O
A
D
Start Switch
L
CLOSED
Output
With Application Of Control Voltage
Output Always Turns ON First
Flashing Output Begins When
ON time = OFF time
Start Switch Is Closed
Solid State Timers and Controllers
.250 Quick Connect
Terminals
Unlike most solid state devices that switch the low or ground side of the DC
operating voltage, the model 423 switches the high side of the DC operating
voltage to an external load circuit when switched "ON." The flash rate can be
specified over a wide range from 1 flash per minute to 600,000 flashes per
minute. The duty cycle of the flashing rate is 50%. Load currents to 1 ampere
may be driven with the output of the model 423. The model 423 has internal
transient protection devices to assure reliable operation even when driving
inductive load circuits such as relays or solenoids. The model 423 is available
only in a fixed flash rate version.
423
MTG. HOLES
(4 PLACES)
-
+
156 DIA.
O
A
D
L
How To Find The Flash Rate. . . . . . . . . . . . . . . . . .
The timing diagram shown below is for an application that
requires the load circuit to be ON for 60 milliseconds and OFF for
60 milliseconds. (Remember - the ON and OFF times will
essentially be equal due to the 50% duty cycle specification
inherent in the model 423)
The voltage across the load circuit would look something this:
50%
ON
1.70
OFF
50%
ON Time = .06 Second (60 milliseconds)
.27
Flash Period = ON + OFF Time
Flash Period = .06 + .06 = .12Seconds
Flash Rate in Flashes Per Minute (F P M)
OFF Time = .06 Second (60 milliseconds)
F P M
F P M
.90
DC Flasher
Solid State
= 60
= 60
Flash Period
.12 = 500 Flashes-Per-Minute
.76
.20
.36
2.25
2.65

Related parts for 423-12-60FPM

423-12-60FPM Summary of contents

Page 1

... The duty cycle of the flashing rate is 50%. Load currents to 1 ampere may be driven with the output of the model 423. The model 423 has internal transient protection devices to assure reliable operation even when driving inductive load circuits such as relays or solenoids ...

Page 2

... Is a model 423 with 24V DC operating voltage, with a fixed FPM (Flashes Per Minute) of 500. Voltage to the load circuit is ON for 60 milliseconds, and OFF for 60 milliseconds. 423 - 24VDC - 30000 Is a model 423 with 24V DC operating voltage, with a fixed FPM (Flashes Per Minute) of 30,000. Voltage to the load circuit is ON for 1 millisecond, and OFF for 1 millisecond. ...