Relay; SSR; Timing; Flasher; Cur-Rtg 0-1A; Ctrl-V 12DC; Quick Connect; 60FPM
Manufacturer
ARTISAN CONTROLS
Datasheet

Specifications of 423-12-60FPM

Current, Rating
1 A
Depth
0.76 in.
Duty Cycle
50%
Function
Timing
Length
2.65 in.
Relay Type
Solid State
Temperature, Operating, Maximum
85 °C
Temperature, Operating, Minimum
-20 °C
Termination
Quick Connect
Timer Type
Flasher
Timing Range
60 FPM
Voltage, Control
12 VDC
Width
1.7 in.
Lead Free Status / Rohs Status
RoHS Compliant part
Flash Rate Duty Cycle Tolerance:
Repeatability Of Flashing Period:
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Examples Of Part Numbers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output Switch Characteristics:
Tolerances On Flashing Rate:
423 - 12VDC - 90
423 - 24VDC - 500
423 - 24VDC - 30000 Is a model 423 with 24V DC operating voltage, with a fixed FPM (Flashes Per Minute)
Data Sheet Revision Date:
Operating Temperature:
Flash Rate Duty Cycle:
Flash Rate Variation:
Voltage Tolerances:
Fixed Flash Rate:
Solid State Timers and Controllers
Part Number
Output Rating:
Recycle Time:
Construction:
Timing Mode:
423 -
of 90
of 500.
of 30,000.
Is a model 423 with 12V DC operating voltage, with a fixed FPM (Flashes Per Minute)
Is a model 423 with 24V DC operating voltage, with a fixed FPM (Flashes Per Minute)
Voltage to the load circuit is ON for 333 milliseconds, and OFF for 333 milliseconds.
Voltage to the load circuit is ON for 60 milliseconds, and OFF for 60 milliseconds.
Voltage to the load circuit is ON for 1 millisecond, and OFF for 1 millisecond.
Dielectric:
Voltage:
Operating Voltage
5V DC, 12V DC, 24V DC, 48V DC.
Flasher.
Factory fixed at any rate from 1 to 600,000 flashes-per-
minute (FPM)
50%.
Less than 4% over full temperature and voltage range.
Operating voltage must be removed for a minimum of 10
milliseconds to assure that the flasher and output circuits are
reset.
0 to 1A inductive with inrush current to 20A for 10
milliseconds.
3 volt drop maximum across output switch when ON and load
current is 1A, 5mA leakage when OFF.
1500V rms all terminals to case.
-20˚C to +85˚C.
Encapsulated module with .25 quick connect wiring
terminals.
September 5, 2000
12V DC
24V DC
48V DC
20%.
10%.
10%
1% at stabilized operating voltage temperature.
5V DC
Flashes Per Minute
From 1 To 600,000