F-70X Triad Magnetics, F-70X Datasheet

no-image

F-70X

Manufacturer Part Number
F-70X
Description
Transformer; Chassis; Pri:115V; Sec:12.6VCT; Sec:1A; Lead; 50/60Hz; 2-13/16W; 1-15/16In.
Manufacturer
Triad Magnetics
Type
Powerr
Datasheet

Specifications of F-70X

Brand/series
F Series
Configuration
Bobbin
Current, Secondary
1 A
Dimensions
3-5/16"W×1-15/16"H×1-3/4"D
Frequency
50/60 Hz
Length, Lead
7 "
Mounting Hole Centers
2.812 "
Mounting Type
Panel/Chassis
Number Of Outlets
2
Phase
1
Standards
UL
Temperature, Operating
+35 °C
Termination
Leadwires
Voltage, Primary
115 VAC
Voltage, Secondary
12.6 (C.T.) VAC
Weight
1.3 lbs.
Peak Reflow Compatible (260 C)
Yes
Leaded Process Compatible
Yes
Rohs Compliant
Yes
Primary Voltages
1 X 115V
Secondary Voltages
1 X 12.6V
Current Rating
1A
Lead Free Status / Rohs Status
RoHS Compliant part
F-70X
Electrical Specifications (@25C)
1. Maximum Power: 12.6 VA
2. Primary: 115V 50/60 Hz
3. Secondary: 12.6VCT @ 1.0 Amps
4. Voltage Regulation: 20 % TYP @ full load to no load
5. Temperature Rise: 35C TYP (45C MAX allowed)
Description:
The F-7X is part of a series which has a long history of reliable service in the field,
made from a proven design and constructed with UL recognized materials.
Construction:
Wound on a single channel nylon bobbin. Materials are UL recognized, Class B
(130º C) rated.
Safety:
These products are 100% hipot tested with an insulation of 1500V between
primary and secondary windings as well as between the primary / secondary
windings and the core.
Dimensions:
Mounting Hole Diameter: .187 in
Lead length: 7.0 inches + 1 inch
Weight: 1.30 lbs
Schematic:
Primary:
Secondary: Yellow to Yellow
RoHS Compliance:
products meet the requirements of 2002/95/EC, known as the RoHS initiative.
1.937
A
5.312
B
Black to Black
1.750
C
As of manufacturing date February 2005, all standard
Units: In inches
2.812
D
BLK
BLK
YEL
YEL/RED
YEL
P
Chassis Mount: Single Secondary
O W E R
T
R A N S F O R M E R
BLK
BLK
B
D
A
C
YEL
BLU
BLU

Related parts for F-70X

F-70X Summary of contents

Page 1

... F-70X Electrical Specifications (@25C) 1. Maximum Power: 12 Primary: 115V 50/ Secondary: 12.6VCT @ 1.0 Amps 4. Voltage Regulation TYP @ full load to no load 5. Temperature Rise: 35C TYP (45C MAX allowed) Description: The F-7X is part of a series which has a long history of reliable service in the field, made from a proven design and constructed with UL recognized materials. ...

Page 2

... Triad offers a full choice of power supply transformers for direct use or in transformer, rectifier, or filter circuits. Other available secondary voltages include control, filament and low level signaling in standard values. The transformers are single primary with single and multiple secondaries in standard size and weight configurations. ...

Page 3

... F-217X# 12.0 1.200 B F-218X# 12.0 2.000 F-219X# 12.0 4.000 F-220U# 12.0 6.000 F-221U# 12.0 8.000 F-29U† 12 11 10.0 CT F-70X 12.6 CT 1.000 F-25X 12.6 CT 1.500 F-325X 12.6 CT 1.500 F-44X# 12.6 CT 2.000 F-344X 12.6 CT 2.000 D F-26X# 12.6 CT 2.500 F-326X 12 ...

Page 4

... Wingdings may be connected in series to obtain their combined voltage when properly phased. Current will be equal to the current of the lowest winding. Example: Two 6.3 V windings @ 2A in series would be 12 2A. Wingdings may also be connected in parallel to obtain combined current. Example: Two 6.3 V windings @ 2A in parallel would be 6 ...

Related keywords