Description
Circuit Breaker; Therm; Push; Cur-Rtg 13A; Panel; 1 Pole; Vol-Rtg 240/48VAC/VDC
Manufacturer
E-T-A Circuit Protection and Control
Type
Thermalr
Datasheet

Specifications of 1140-G111-P1M1-13A

Actuator Type
Push
Application
Motors, transformers, solenoids, hand-held machines and appliances
Brand/series
1140 Series
Characteristic
Medium Delay
Color, Button
Black
Current, Rating
13 A
Dielectric Strength
3000
Dimensions
0.748"Lx0.433"Wx1.36"H
Mounting Hole Size
0.35x0.378 "
Mounting Type
Panel
Number Of Poles
1
Resistance, Insulation
100 Megohms @ 500 VDC
Standards
UL, CSA, VDE Approvals
Temperature, Operating, Maximum
60 °C
Temperature, Operating, Minimum
-20 °C
Termination
Blade
Voltage, Rating
240/48 VAC/VDC
Lead Free Status / Rohs Status
RoHS Compliant part
Miniaturised single pole thermal circuit breaker with push-to-reset tease-
free, trip-free, snap action mechanism (R-type TO CBE to EN 60934).
Available in versions for panel mounting, snap-in or threadneck, or as
an integral type. For lower current ratings see types 104, 105, 106.
Approved to CBE standard EN 60934 (IEC 60934).
Motors, transformers, solenoids, hand-held machines and appliances.
Type No.
1140
1140 - F1 1 1 - P1 M1 - 10 A
*mounting hardware bulk shipped
Current
rating (A)
3.5
4
5
6
7
8
Authority
VDE
CSA, UL
Kema (EN 60934)
Description
Typical applications
Ordering information
Standard current ratings and typical internal resistance values
Approvals
single pole thermal circuit breaker
Mounting
E2
F1
G1
G4
integral mounting
snap-in panel mounting
threadneck panel mounting 3/8-27UNS with hex nut and
knurled nut*
threadneck panel mounting 3/8-27UNS with knurled nut*
Number of poles
1
1-pole protected
Actuator style
1
Internal
resistance (Ω)
0.06
0.04
0.03
0.02
< 0.02
< 0.02
black push button (standard)
Terminal design
P1
Thermal Overcurrent Circuit Breaker 1140-...
blade terminals A6.3-0.8 (QC .250)
Characteristic curve
M1
Voltage ratings
AC 240 V; DC 48 V
AC 250 V; DC 50 V
AC 240 V; DC 48 V
Current ratings
3.5...16 A
medium delaye
= ordering example
Current
rating (A)
10
12
13
15
16
Current ratings
3.5...16 A
3.5...16 A
3.5...16 A
Internal
resistance (Ω)
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
For further details please see chapter: Technical Information
Voltage rating
Current ratings
Typical life
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664 A)
Dielectric strength
(IEC 60664 and 60664A)
Insulation resistance
Interrupting capacity I
Interrupting capacity
(UL 10777)
Degree of protection
(IEC 60529/DIN 40 050)
Vibration
Shock
Corrosion
Humidity
Mass
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications
without notice is reserved.Product markings may not be exactly as the ordering codes.
Errors and omissions excepted.
Technical data
AC + DC
operating area
1140-E...
3.5...8 A
9...16 A
cn
AC 240 V; DC 48 V
(UL: AC 250 V; DC 50 V)
3.5...16 A
200 operations at 2 x I
1,000 operations at 2 x I
100 operations at 2 x I
-20...+60 °C (-4...+140 °F) T 60
rated impulse
withstand voltage
2.5 kV
reinforced insulation in operating area
test voltage
AC 3,000 V
> 100 MΩ (DC 500 V)
3.5...8 A
10...16 A
I
3.5...16 A
3.5...7A
8...16 A
operating area IP40
terminal area IP00
10 g (57-500 Hz) ± 0.76 mm (10-57 Hz),
to IEC 60068-2-6, test Fc,
10 frequency cycles/axis
25 g (11 ms)
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH
to IEC 60068-2-3, test Ca
approx. 10 g
N
1140-F...
8 x I
120 A
U
DC 50 V
AC 250 V
AC 250 V
N
N
N
N
pollution
degree
2
1140-G.1.
, inductive
, inductive
N
, resistive
200 A
1,000 A
2,000 A
1 - 31
1