482-G212-K1M1-A1S0-2.5 E-T-A Circuit Protection and Control, 482-G212-K1M1-A1S0-2.5 Datasheet

no-image

482-G212-K1M1-A1S0-2.5

Manufacturer Part Number
482-G212-K1M1-A1S0-2.5
Description
Circuit Breaker; Therm; Push/Pull; Cur-Rtg 2.5A; Panel; 1 Pole; Vol-Rtg 115/28VAC/VDC
Manufacturer
E-T-A Circuit Protection and Control
Type
Thermalr
Datasheet

Specifications of 482-G212-K1M1-A1S0-2.5

Actuator Type
Push/Pull
Brand/series
482 Series
Characteristic
Thermal
Current, Rating
2.5 A
Dimensions
1.22"Lx0.709"Wx1.89"H
Mounting Hole Size
0.492 "
Mounting Type
Panel
Number Of Poles
1
Termination
Screw
Voltage, Rating
115/28 VAC/VDC
Single pole compact high performance thermal circuit breaker with
tease-free, trip-free, snap action mechanism and push/pull on/off
manual actuation (M-type TO CBE to EN 60934). An indicator band
on the push button clearly shows the tripped/off position. Threadneck
panel mounted in tracked vehicle and aircraft/general purpose versions,
with optional auxiliary contacts.
Extra low voltage wiring systems on all types of vehicles for land, sea
and air, battery powered machines, process control.
Type No.
482
482 - G 1 1 1 - K1 M1 - A 1
Description
Typical applications
Ordering information
single pole thermal circuit breaker
Mounting
G
threadneck panel mounting
Threadneck design
1
2
3
6
7
M 12x1 nickel plated
M 12x1 black
15/32-UN-2A black
M12x1x8 black, without locating pin,
push button marking as with 482-G2..
M12x1x6,4 black, without locating pin,
push button marking as with 482-G1..
Hardware - washer for threadneck
0
1
2
3
without hardware
corrugated washer 12/15, fitted
serrated lock washer 12/15, fitted (MS 35333-136)
serrated lock washer 12/15, bulk shipped (MS 35333-136)
Hardware - hex nut for threadneck
0
1
2
3
4
without hardware
hex nut M12x1 nickel plated
hex nut M12x1 black
hex nut 15/32-UN-2B black, fitted
hex nut 15/32-UN-2B black, bulk shipped
Terminal design (main terminals)
K1
J1
R1
screw terminals with metric thread M4
screw terminals with inch thread 8-32-UNC-2B
round connector ø6
Characteristic curve
M1
High Performance Thermal Circuit Breaker 482-...
thermal 1.15-1.4 I
Terminal screws
A
B
F
H
K
flat head screw M4x6, ISO 1580, fitted
Phillips screw 8-32UNC-2Ax6
(MS 51957-41), fitted
Phillips screw M4x6 (ISO 7045), bulk shipped
socket head cap screw
M4x6 (DIN 7984), fitted
hex screw 8-32UNC-3Ax7.6 fitted
Terminal washers
0
1
2
3
5
6
without lock washer
lock washer DIN 137-B4, fitted
lock washer 4.3, fitted, MS 35338-137
lock washer 4.3, bulk shipped
(MS 35338-137)
lock washer 4.3/9, fitted
lock washer DIN 137-B4, bulk shipped
Auxiliary contact
S0
S1
S5
S1
Barrier
(blank)
T
without auxiliary contacts
with auxiliary contact (NC)
with polarized aux. contact (NC)
. -
N
without barrier
with barrier, 31 mm wide
Current ratings
0.1...50 A
10 A
ordering example
Dielectric strength
(IEC 60664 and 60664A)
Mass
Voltage rating
Current rating range
Auxiliary circuit
Typical life
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664A)
Insulation resistance
Interrupting capacity I
Interrupting capacity
(UL 1077)
Degree of protection
(IEC 60529/DIN 40050
Vibration
Shock
Corrosion
Humidity
Explosion
Authority
VG 95345 T21
QPL, Canada
UL, CSA
Previous ordering codes:
482-N-MS = 482-G111-K1M1-A1S0-...A
482-MS
Technical data
Approvals
operating area
main to aux. circuit
without aux. contacts
= 482-G212-K1M1-A1S0-...A
Voltage ratings
DC 28 V
DC 28 V
DC 72 V
cn
AC 115 V (400 Hz); DC 28 V
AC 230 (50/60 Hz) to special order
0.1...50 A
0.5 A, DC 28 V
10,000 operations mechanical
5,000 operations at I
-55...+75 °C (-67...+167 °F)
rated impulse
withstand voltage
1.5 kV
test voltage
AC 1,500 V
AC 1,500 V
> 100 MΩ (DC 500 V)
0.1...2.5 A
3...3.5 A
4...7 A
7.5...50 A
35...50 A
I
0.1...50 A
operating area IP40
terminal area IP00
10 g (55-2000 Hz), ± 0.76 mm (10-55 Hz)
to VG 95210, sheet 19/IEC 60068-2-6, test Fc
50 g (11 ms)
to VG 95210, sheet 28/IEC 60068-2-27, test Ea
48 hours at 5 % salt mist
to VG 95210, sheet 2/IEC 60068-2-11, test Ka
240 hours at 95 % RH
to VG 95210, sheet 7/IEC 60068-2-3, test C
to VG 95210, sheet 10/MIL-STD-202,
meth. 109
approx. 43 g without auxiliary contact
approx. 46 g with auxiliary contact
N
482
Current ratings
0.1...50 A
0.5...35 A
0.1...50 A
250 A DC / 150 A AC
500 A
15 x I
6,000 A DC / 1,000 A AC
with auxiliary contact:
3,000 A DC / 1,000 A AC
U
DC 72 V
with aux. contacts
N
N
N
pollution
degree
3
5,000 A
4 - 37
4

Related parts for 482-G212-K1M1-A1S0-2.5

482-G212-K1M1-A1S0-2.5 Summary of contents

Page 1

... S1 with auxiliary contact (NC) S5 with polarized aux. contact (NC) Barrier without barrier (blank) T with barrier wide Current ratings 0.1...50 A 482 - without aux. contacts Technical data Voltage rating Current rating range Auxiliary circuit Typical life Ambient temperature Insulation co-ordination ...

Page 2

... High Performance Thermal Circuit Breaker 482-... Standard current ratings and typical volt drop values Current Volt drop rating (A) (mV) 0.1 16,000 0.2 8,000 0.5 3,000 0.8 2,000 1 1,500 1.2 1,200 1.5 1,000 1.8 850 2 800 2.5 700 3 600 4 430 Dimensions 482-G1... ...

Page 3

... High Performance Thermal Circuit Breaker 482-... Dimensions 482-G3... 482-G323-J1M1-B2 (MS 25 244) tightening torque max 15/32-32-UNS-2A THD Phillips screw MS 51957-41(8-32UNC-2A) with lock washer MS 35338-137 17.9 tightening torque max. 1.2 Nm .704 mounting holes min. ø3.2 location pin current rating in A min .126 9.5 ...

Related keywords