BAT43 Vishay / Small Signal & Opto Products (SSP), BAT43 Datasheet - Page 2
BAT43
Manufacturer Part Number
BAT43
Description
Diode; 200 mA (continuous); 30 V (Min.) @ 25 degC(Reverse); 0.45 V (Max.); 200 m
Manufacturer
Vishay / Small Signal & Opto Products (SSP)
Datasheet
1.BAT43.pdf
(3 pages)
Specifications of BAT43
Capacitance
7 pF (Typ.)
Capacitance, Junction
7 pF
Current, Forward
200 mA
Current, Reverse
100 μA
Current, Surge
4 A
Package Type
DO-35
Power Dissipation
200 mW
Primary Type
Schottky Barrier
Speed, Switching
Standard
Temperature, Junction, Maximum
+125 °C
Temperature, Operating
-65 to +125 °C
Thermal Resistance, Junction To Ambient
300 °C⁄W
Time, Recovery
5 ns
Time, Reverse Recovery
5 nS (Max.)
Voltage, Breakdown
30 V (Min.) @ 25°C(Reverse)
Voltage, Forward
450 mV
Voltage, Repetitive Peak Reverse
30 V
Voltage, Reverse
30 V
Lead Free Status / Rohs Status
RoHS Compliant part
Electrostatic Device
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Part Number:
BAT43-TAP
Manufacturer:
VISHAY/威世
Quantity:
20 000
Part Number:
BAT4343NA
Manufacturer:
BB
Quantity:
20 000
Part Number:
BAT4343NR
Manufacturer:
BB
Quantity:
20 000
Part Number:
BAT43W
Manufacturer:
PANJIT/强茂
Quantity:
20 000
Part Number:
BAT43W RH
Manufacturer:
TSMC
Quantity:
20 000
Company:
Part Number:
BAT43W T/R
Manufacturer:
PANJIT
Quantity:
11 500
Company:
Part Number:
BAT43W-7
Manufacturer:
MICRONAS
Quantity:
16
Company:
Part Number:
BAT43W-7-F
Manufacturer:
Diodes Inc
Quantity:
25 895
BAT42/BAT43
Vishay Semiconductors
Thermal Characteristics
T
1)
Electrical Characteristics
T
1)
Typical Characteristics
T
2
Figure 1. Admissible Power Dissipation vs. Ambient Temperature
Thermal resistance junction to ambient air
Junction temperature
Ambient operating temperature range
Storage temperature range
Reverse breakdown voltage
Leakage current
Forward voltage
Diode capacitance
Reverse recovery time
Rectification efficieny
amb
amb
amb
Valid provided that leads at a distance of 4 mm from case are kept at ambient temperature
Pulse test t
= 25 °C, unless otherwise specified
= 25 °C, unless otherwise specified
= 25 °C, unless otherwise specified
18442
Parameter
250
200
150
100
50
p
0
< 300 µs, t
0
1)
Parameter
1)
T
amb
50
p
/T < 0.02
- Ambient Temperature (°C)
100
I
V
V
I
I
I
I
I
V
I
i
R
f = 45 MHz, V
R
R
F
F
F
F
F
F
R
R
R
L
= 200 mA
= 10 mA
= 50 mA
= 2 mA
= 15 mA
= 10 mA, I
= 1 mA, R
= 100 µA (pulsed)
= 15 kΩ, C
= 25 V
= 25 V, T
= 1 V, f = 1 MHz
150
Test condition
j
L
R
= 100 °C
RF
= 100 Ω
L
= 10 mA,
= 300 pF,
200
= 2 V
Test condition
BAT42
BAT42
BAT43
BAT43
Part
18443
1000
Symbol
0.01
100
Figure 2. Typical Reverse Characteristics
R
0.1
T
Symbol
10
T
amb
V
thJA
1
T
stg
C
V
V
V
V
V
(BR)
η
j
I
I
t
0
R
R
rr
F
F
F
F
F
D
v
V
F
125 °C
- Instantaneous Forward Voltage (mV)
200
Min
260
30
80
400
- 65 to + 125
- 65 to +150
25 °C
- 40 °C
Value
300
600
125
Typ.
1)
7
800
1000
1000
Max
100
400
650
330
450
0.5
5
1200
Unit
K/W
°C
°C
°C
Unit
mV
mV
mV
mV
mV
µA
µA
pF
ns
%
V