HS7A-DMC7912 IDEC, HS7A-DMC7912 Datasheet

NON-CONTACT SAFETY INTERLOCK SWITCH, DPST-NC, 24VDC

HS7A-DMC7912

Manufacturer Part Number
HS7A-DMC7912
Description
NON-CONTACT SAFETY INTERLOCK SWITCH, DPST-NC, 24VDC
Manufacturer
IDEC
Datasheet

Specifications of HS7A-DMC7912

Contact Configuration
DPST-NC
Contact Voltage Dc Max
24V
Contact Current Dc Max
100mA
HS7A-DMC
Compact size and easy positioning.
Combination with proprietary relay modules achieves safety category 4 (EN954-1).
Types
HR1S-DMB1132
HR1S-DMB1132P
HR1S-DME1132
HR1S-DME1132P
HR1S-AF5130B
HR1S-AF5130PB
Actuator
HR1S-DMB/DME
HR1S-AF5130B/AF5130PB
Package quantity: 1
The HS7A-DMC non-contact interlock switch is supplied with an HS9Z-ZC1
actuator .
The contact configuration in the table above shows the contact status when
the non-contact interlock switch is not activated .
Safety category 3 can be achieved when connecting two or more non-con-
tact interlock switches per one input .
When connecting multiple non-contact interlock switches (HS7A-
DMC790), use HR1S-AF5130B/AF5130PB . (HS7A-DMC791 cannot be
connected in multiple numbers .)
Non-contact Interlock Switch
One HS9Z-ZC1 is supplied with each HS7A-DMC non-contact interlock
switch .
HS7A Non-contact Interlock Switches
Configura-
HR1S Safety Relay Modules for
Non-contact Interlock Switches
Maximum Number of Connectable Non-contact In-
terlock Switches per Input of Safety Relay Module
Accessory
Compact size (7 × 16 × 51mm)
Positioning for installation is easy .
Up to 36 sets can be connected .
(safety relay module: HR1S-DME)
Degree of protection: IP67
1NO+1NC
Safety Relay Module
Contact
The HS7A-DMC non-contact interlock switches can be
used as interlock switches when used in combination
with safety relay modules specified by IDEC .
2NO
tion
Name
Length
Cable
10m
10m
2m
5m
2m
5m
Without HS7A-DMC5902
Without HS7A-DMC5905
Without HS7A-DMC59010
Without HS7A-DMC7902
Without HS7A-DMC7905
Without HS7A-DMC79010
LED
With
With
With
With
With
With
Number of Inputs
Without
HS7A-DMC59
Ordering Type No.
HS7A-DMC5912
HS7A-DMC5915
HS7A-DMC59110
HS7A-DMC7912
HS7A-DMC7915
HS7A-DMC79110
2
6
1
LED
6
Ordering Type No.
With
LED
Non-contact Interlock Switches
HS9Z-ZC1
Connectable Non-contact
3
Interlock Switches
Max. Number of
Without
HR1S-DMB1132
HR1S-DMB1132P
HR1S-DME1132
HR1S-DME1132P
HR1S-AF5130B
HR1S-AF5130PB
Applicable Safety
HS7A-DMC79
LED
Relay Module
6
12
36
6
With
LED
1
Specifications
Dimensions
Applicable Standards
Operating Temperature
Relative Humidity
Storage Temperature
Pollution Degree
Electric Shock Protection
Degree of Protection
Shock Resistance
Vibration Resistance
Rated Voltage (Ue)
Rated Current (Ie)
Repeat Accuracy
Hysteresis
Maximum Operating Frequency 150 Hz
Voltage Drop
Housing Material
Housing Color
Cable
Weight (approx .)
HS7A-DMC
(Non-contact
Interlock Switch)
2-ø3.5
2-ø6
12.5
16
I = 10 mA
I = 100 mA
7
3.5
Minimum Radius
30 mm
UL508 (UL listed)
CSA C22 .2, No . 14
IEC/EN 60947-5-1
IEC/EN 60947-5-2
IEC/EN 60947-5-3
–25 to 85°C (no freezing)
30 to 85% (no condensation)
–40 to +85°C (no freezing)
3
Class II (IEC 60536)
IP67 (IEC 60529)
300 m/s
100 m/s
24V DC
100 mA
10% maximum
20% maximum
0 .1V (without LED) / 2 .4V (with LED)
1V (without LED) / 4 .2V (with LED)
PBT
Red
AWG23 (0 .25 mm
Cable length: 2m, 5m, 10m
HS7A-DMC: 100g (cable length: 2m)
HS9Z-ZC1: 9g
2
2
(11 ms) (IEC 60068-2-7)
(10 to 150 Hz) (IEC 60068-2-6)
HS9Z-ZC1 (Actuator)
3.5
All dimensions in mm .
2
7
) × 4
16
2-ø3.5
2-ø6
685
Flush
Silhouette
Control
Units
Display
Lights
Display
Units
Safety
Products
Terminal
Blocks
Comm.
Terminals
AS-Interface
Relays &
Timers
Sockets
Circuit
Protectors
Power
Supplies
PLCs &
SmartRelay
Operator
Interfaces
Sensors
Control
Stations
Explosion
Protection
References

Related parts for HS7A-DMC7912

HS7A-DMC7912 Summary of contents

Page 1

... Without HS7A-DMC5902 2m With HS7A-DMC5912 Without HS7A-DMC5905 1NO+1NC 5m With HS7A-DMC5915 Without HS7A-DMC59010 10m With HS7A-DMC59110 Without HS7A-DMC7902 2m With HS7A-DMC7912 Without HS7A-DMC7905 2NO 5m With HS7A-DMC7915 Without HS7A-DMC79010 10m With HS7A-DMC79110 • Package quantity: 1 • The HS7A-DMC non-contact interlock switch is supplied with an HS9Z-ZC1 actuator . • ...

Page 2

... Power A1/A2 Fault LOGIC K1/K2 A2 S21 S22 S23 S41 S42 Guard 2: Closed Guard 4: Closed ESC: External Start Condition Safety Category 4 (EN 954-1) Circuit, HR1S-AF5130B/AF5130PB + HS7A-DMC791 • F1 (protection fuse for the power of safety relay module) L (+) 24V Start Switch ESC A1 S33 S34 S39 T ...

Page 3

... Safety category 3 (EN 954-1) • HR1S-DMB + HS7A-DMC591 (1NO+1NC) + HS9Z-ZC1 F1 (protection fuse for the power of safety relay module) +24V Guard 1: Closed S1.1 Brown + White Black Blue HS7A-DMC S1.2 Brown + White Black Blue Start Switch S1.3 Brown + S3 White ESC Black Blue A1 S11 ...

Page 4

... Be sure to use the HS7A non-contact interlock switch in combina- • tion with the proprietary actuator HS9Z-ZC1 . Do not use other actuators ...

Page 5

... HR1S-DMB/DME 6 3 HR1S-AF5130B/AF5130PB — — Accessory • Name Ordering Type No. Actuator HS9Z-ZP1 • One HS9Z-ZP1 is supplied with the HS7A-DMP non-contact interlock switch . Specifications Applicable Standards Applicable Safety Relay Module Operating Temperature HR1S-DMB1132 Relative Humidity HR1S-DMB1132P HR1S-DME1132 Storage Temperature HR1S-DME1132P Pollution Degree ...

Page 6

... F: Protection fuse for monitor signal contacts (max . 500mA gG (gL Note: The circuit example shown on the left (HR1S-AF and HS7A-DMP70) may not conform to safety cate- gory 4 depending on the operating conditions, such as the frequency of safety function check . Perform risk assessment of your system before operation . 14 ...

Page 7

... Be sure to use the HS7A non-contact interlock switch in combina- • tion with the proprietary actuator HS9Z-ZP1 . Do not use other actuators ...

Related keywords