NON-CONTACT SAFETY INTERLOCK SWITCH, DPST-NC, 24VDC

HS7A-DMC7902

Manufacturer Part NumberHS7A-DMC7902
DescriptionNON-CONTACT SAFETY INTERLOCK SWITCH, DPST-NC, 24VDC
ManufacturerIDEC
HS7A-DMC7902 datasheet
 

Specifications of HS7A-DMC7902

Contact ConfigurationDPST-NCContact Voltage Dc Max24V
Contact Current Dc Max100mA  
1
Page 1
2
Page 2
3
Page 3
4
Page 4
5
Page 5
6
Page 6
7
Page 7
Page 1/7

Download datasheet (2Mb)Embed
Next
HS7A-DMC
Non-contact Interlock Switches
Compact size and easy positioning.
Combination with proprietary relay modules achieves safety category 4 (EN954-1).
Compact size (7 × 16 × 51mm)
Positioning for installation is easy .
Up to 36 sets can be connected .
(safety relay module: HR1S-DME)
Degree of protection: IP67
The HS7A-DMC non-contact interlock switches can be
used as interlock switches when used in combination
with safety relay modules specified by IDEC .
Types
HS7A Non-contact Interlock Switches
Contact
Cable
Configura-
LED
Ordering Type No.
Length
tion
Without HS7A-DMC5902
2m
With
HS7A-DMC5912
Without HS7A-DMC5905
1NO+1NC
5m
With
HS7A-DMC5915
Without HS7A-DMC59010
10m
With
HS7A-DMC59110
Without HS7A-DMC7902
2m
With
HS7A-DMC7912
Without HS7A-DMC7905
2NO
5m
With
HS7A-DMC7915
Without HS7A-DMC79010
10m
With
HS7A-DMC79110
Package quantity: 1
The HS7A-DMC non-contact interlock switch is supplied with an HS9Z-ZC1
actuator .
The contact configuration in the table above shows the contact status when
the non-contact interlock switch is not activated .
HR1S Safety Relay Modules for
Non-contact Interlock Switches
Safety Relay Module
Number of Inputs
Connectable Non-contact
HR1S-DMB1132
2
HR1S-DMB1132P
HR1S-DME1132
6
HR1S-DME1132P
HR1S-AF5130B
1
HR1S-AF5130PB
Safety category 3 can be achieved when connecting two or more non-con-
tact interlock switches per one input .
When connecting multiple non-contact interlock switches (HS7A-
DMC790), use HR1S-AF5130B/AF5130PB . (HS7A-DMC791 cannot be
connected in multiple numbers .)
Maximum Number of Connectable Non-contact In-
terlock Switches per Input of Safety Relay Module
HS7A-DMC59
Non-contact Interlock Switch
Without
With
LED
LED
HR1S-DMB/DME
6
3
HR1S-AF5130B/AF5130PB
Accessory
Name
Ordering Type No.
Actuator
HS9Z-ZC1
One HS9Z-ZC1 is supplied with each HS7A-DMC non-contact interlock
switch .
Specifications
Applicable Standards
Applicable Safety
Relay Module
Operating Temperature
Relative Humidity
HR1S-DMB1132
HR1S-DMB1132P
Storage Temperature
HR1S-DME1132
Pollution Degree
HR1S-DME1132P
Electric Shock Protection
Degree of Protection
Shock Resistance
Vibration Resistance
HR1S-AF5130B
Rated Voltage (Ue)
HR1S-AF5130PB
Rated Current (Ie)
Repeat Accuracy
Hysteresis
Maximum Operating Frequency 150 Hz
I = 10 mA
Voltage Drop
I = 100 mA
Housing Material
Housing Color
Cable
Max. Number of
Weight (approx .)
Interlock Switches
12
Dimensions
36
HS7A-DMC
(Non-contact
6
Interlock Switch)
16
7
12.5
2-ø6
HS7A-DMC79
2-ø3.5
Without
With
LED
LED
6
1
UL508 (UL listed)
CSA C22 .2, No . 14
IEC/EN 60947-5-1
IEC/EN 60947-5-2
IEC/EN 60947-5-3
–25 to 85°C (no freezing)
30 to 85% (no condensation)
–40 to +85°C (no freezing)
3
Class II (IEC 60536)
IP67 (IEC 60529)
300 m/s
(11 ms) (IEC 60068-2-7)
2
100 m/s
(10 to 150 Hz) (IEC 60068-2-6)
2
24V DC
100 mA
10% maximum
20% maximum
0 .1V (without LED) / 2 .4V (with LED)
1V (without LED) / 4 .2V (with LED)
PBT
Red
AWG23 (0 .25 mm
2
) × 4
Cable length: 2m, 5m, 10m
HS7A-DMC: 100g (cable length: 2m)
HS9Z-ZC1: 9g
HS9Z-ZC1 (Actuator)
7
3.5
3.5
16
2-ø6
2-ø3.5
Minimum Radius
30 mm
All dimensions in mm .
685
Flush
Silhouette
Control
Units
Display
Lights
Display
Units
Safety
Products
Terminal
Blocks
Comm.
Terminals
AS-Interface
Relays &
Timers
Sockets
Circuit
Protectors
Power
Supplies
PLCs &
SmartRelay
Operator
Interfaces
Sensors
Control
Stations
Explosion
Protection
References

HS7A-DMC7902 Summary of contents

  • Page 1

    ... Ordering Type No. Length tion Without HS7A-DMC5902 2m With HS7A-DMC5912 Without HS7A-DMC5905 1NO+1NC 5m With HS7A-DMC5915 Without HS7A-DMC59010 10m With HS7A-DMC59110 Without HS7A-DMC7902 2m With HS7A-DMC7912 Without HS7A-DMC7905 2NO 5m With HS7A-DMC7915 Without HS7A-DMC79010 10m With HS7A-DMC79110 • Package quantity: 1 • The HS7A-DMC non-contact interlock switch is supplied with an HS9Z-ZC1 actuator . • ...

  • Page 2

    ... Power A1/A2 Fault LOGIC K1/K2 A2 S21 S22 S23 S41 S42 Guard 2: Closed Guard 4: Closed ESC: External Start Condition Safety Category 4 (EN 954-1) Circuit, HR1S-AF5130B/AF5130PB + HS7A-DMC791 • F1 (protection fuse for the power of safety relay module) L (+) 24V Start Switch ESC A1 S33 S34 S39 T ...

  • Page 3

    ... Safety category 3 (EN 954-1) • HR1S-DMB + HS7A-DMC591 (1NO+1NC) + HS9Z-ZC1 F1 (protection fuse for the power of safety relay module) +24V Guard 1: Closed S1.1 Brown + White Black Blue HS7A-DMC S1.2 Brown + White Black Blue Start Switch S1.3 Brown + S3 White ESC Black Blue A1 S11 ...

  • Page 4

    ... Be sure to use the HS7A non-contact interlock switch in combina- • tion with the proprietary actuator HS9Z-ZC1 . Do not use other actuators ...

  • Page 5

    ... HR1S-DMB/DME 6 3 HR1S-AF5130B/AF5130PB — — Accessory • Name Ordering Type No. Actuator HS9Z-ZP1 • One HS9Z-ZP1 is supplied with the HS7A-DMP non-contact interlock switch . Specifications Applicable Standards Applicable Safety Relay Module Operating Temperature HR1S-DMB1132 Relative Humidity HR1S-DMB1132P HR1S-DME1132 Storage Temperature HR1S-DME1132P Pollution Degree ...

  • Page 6

    ... F: Protection fuse for monitor signal contacts (max . 500mA gG (gL Note: The circuit example shown on the left (HR1S-AF and HS7A-DMP70) may not conform to safety cate- gory 4 depending on the operating conditions, such as the frequency of safety function check . Perform risk assessment of your system before operation . 14 ...

  • Page 7

    ... Be sure to use the HS7A non-contact interlock switch in combina- • tion with the proprietary actuator HS9Z-ZP1 . Do not use other actuators ...