HAS 100-S LEM USA Inc, HAS 100-S Datasheet - Page 3

SENSOR CURR 100A -/+15V MOD

HAS 100-S

Manufacturer Part Number
HAS 100-S
Description
SENSOR CURR 100A -/+15V MOD
Manufacturer
LEM USA Inc
Series
HASr
Datasheet

Specifications of HAS 100-S

Current - Sensing
100A
Accuracy
±1%
Sensitivity
-
Current - Supply
±15mA
Sensor Type
Open Loop Hall Effect
Voltage - Supply
-15 V ~ 15 V
Output
-
Frequency
50kHz
Polarization
Bidirectional
Operating Temperature
-10°C ~ 80°C
Package / Case
Module
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
398-1050
Dimensions HAS 50 .. 600-S
Mechanical characteristic
Notes:
090914/10
Dimensions HAS 50..600-S
061019/7
General tolerance
1)
2)
3)
4)
5)
Operating at ± 12 V ≤ V
If the customer uses 1 kΩ of the load resistor, the primary current has to be limited as the nominal.
To measure the full defined measuring range, the load resistor should be at minimum 10 kΩ
Linearity data exclude the electrical offset
Please refer to derating curves in the technical file to avoid excessive core heating at high frequency
Please consult characterisation report for more technical details and application advice;
To IEC 61000-4-3 (2006), Output is above to 15% of Vsn between 200MHz and 700MHz.
5045-04A
2 = 15V
4 = 0V
MOLEX
PINS A RRANGEMENT
3 = OUTPUT
1 = +15V
HAS 50 to 600-S
Dimensions
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
4 3 2 1
C
< ± 15 V will reduce the measuring range
4.5
(in mm. 1 mm = 0.0394 inch)
(in mm. 1 mm = 0.0394 inch)
20.4 x
(in mm)
± 0.5 mm
22.8
40
10.4
16
2.5
r 5.2
(Max. 8.0)
Safety
This transducer must be used in electric/electronic equipment
with respect to applicable standards and safety requirements
in accordance with the following manufacturer's operating
instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can
carry hazardous voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious
damage.
This transducer is a built-in device, whose conducting parts
must be inaccessible after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
I
PINS ARRANGEMENT
1 ..... +15V
2 ..... -15V
3 ..... OUTPUT
4 ..... 0V
Secondary terminals
1
2
3
4
20
30
= =
: Supply voltage + 15 V
: Supply voltage - 15 V
: Output
: 0V
www.lem.com
www.lem.com
Page 3/3
Page 2/2

Related parts for HAS 100-S