M58WR032KU70ZA6U NUMONYX, M58WR032KU70ZA6U Datasheet - Page 100

no-image

M58WR032KU70ZA6U

Manufacturer Part Number
M58WR032KU70ZA6U
Description
NUMM58WR032KU70ZA6U NUM 32MB NOR FLASH P
Manufacturer
NUMONYX
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M58WR032KU70ZA6U
Manufacturer:
ST
0
Part Number:
M58WR032KU70ZA6U
Manufacturer:
ST
Quantity:
20 000
Common Flash Interface
Table 42.
1. The variable P is a pointer that is defined at CFI offset 15h.
Table 43.
1. The variable P is a pointer that is defined at CFI offset 15h.
Table 44.
1. The variable P is a pointer that is defined at CFI offset 15h.
2. Bank Regions. There are two Bank Regions, see Tables 31, 32, 33, 34,
100/123
(P+10)h = 49h
(P+19)h = 52h
(P+12)h= 4Bh
(P+13)h = 4Ch
(P+14)h = 4Dh
(P+15)h = 4Eh
(P+16)h = 4Fh
(P+E)h = 47h
(P+17)h = 50h
(P+18)h = 51h
(P+F)h = 48h
(P+11)h =
Offset
Offset
Offset
M58WR032KU
4Ah
Protection Register information
Burst Read Information
Bank and Erase block region information
Data
0001h
0080h
0000h
0003h
0004h
02h
0003h
0004h
0001h
0002h
0003h
0007h
Data
Data
(P+19)h = 52h
Number of protection register fields in JEDEC ID space. 0000h indicates
that 256 fields are available.
Protection Field 1: protection description
Bits 0-7 Lower byte of protection register address
Bits 8-15 Upper byte of protection register address
Bits 16-23 2
Bits 24-31 2
Page-mode read capability
bits 0-7’n’ such that 2
bytes. See offset 28h for device word width to determine page-mode data
output width.
Number of synchronous mode read configuration fields that follow.
Synchronous mode read capability configuration 1
bit 3-7Reserved
bit 0-2’n’ such that 2
continuous synchronous reads when the device is configured for its
maximum word width. A value of 07h indicates that the device is capable of
continuous linear bursts that will output data until the internal burst counter
reaches the end of the device’s burstable address space. This field’s 3-bit
value can be written directly to the read configuration register bit 0-2 if the
device is configured for its maximum word width. See offset 28h for word
width to determine the burst data output width.
Synchronous mode read capability configuration 2
Synchronous mode read capability configuration 3
Synchronous mode read capability configuration 4
Offset
M58WR032KL
n
n
(1)
bytes in factory pre-programmed region
bytes in user programmable region
Data
02h
n+1
n
(1)
HEX value represents the number of read-page
HEX value represents the maximum number of
Number of Bank Regions within the device
Description
Description
35
and 36.
Description
M58WRxxxKU, M58WRxxxKL
16 Bytes
8 Bytes
8 Bytes
0080h
Value
Value
Cont.
16
1
4
4
8

Related parts for M58WR032KU70ZA6U