LH28F320BJHE-PTTL90 Sharp Electronics, LH28F320BJHE-PTTL90 Datasheet - Page 26

no-image

LH28F320BJHE-PTTL90

Manufacturer Part Number
LH28F320BJHE-PTTL90
Description
Manufacturer
Sharp Electronics
Datasheet

Specifications of LH28F320BJHE-PTTL90

Cell Type
NOR
Density
32Mb
Access Time (max)
90ns
Interface Type
Parallel
Boot Type
Top
Address Bus
22/21Bit
Operating Supply Voltage (typ)
3.3V
Operating Temp Range
-40C to 85C
Package Type
TSOP
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8/16Bit
Number Of Words
4M/2M
Supply Current
30mA
Mounting
Surface Mount
Pin Count
48
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LH28F320BJHE-PTTL90
Quantity:
1 895
sharp
FULL STATUS CHECK PROCEDURE
Set Lock-Bit Successful
Block/Device Address
Read Status Register
Data(See Above)
Write 01H/F1H,
Check if Desired
Status Register
Set Lock-Bit
Read Status
Write 60H
Full Status
Write 70H
Complete
Register
SR.4,5=
SR.1=
SR.4=
SR.7=
SR.7=
SR.3=
Start
Read
1
1
0
0
0
0
0
0
1
1
1
1
Device Protect Error
Command Sequence
V
Set Lock-Bit Error
CCW
Range Error
Error
Figure 11. Set Block and Permanent Lock-Bit Flowchart
LHF32J04
Repeat for subsequent lock-bit set operations.
Full status check can be done after each lock-bit set operation or after a sequence of
Write FFH after the last lock-bit set operation to place device in read array mode.
SR.5, SR.4, SR.3 and SR.1 are only cleared by the Clear Status Register command in cases
If error is detected, clear the Status Register before attempting retry or other error recovery.
Operation
lock-bit set operations.
Operation
where multiple lock-bits are set before full status is checked.
Standby
Standby
Standby
Standby
Standby
Standby
Write
Write
Write
Read
Read
Bus
Bus
Block or Permanent
Lock-Bit Confirm
Block/Permanent
Lock-Bit Setup
Read Status
Command
Command
Register
Set
Set
Status Register Data
Check SR.7
1=WSM Ready
0=WSM Busy
Data=60H
Addr=X
Data=01H(Block),
Addr=Block Address(Block),
Status Register Data
Check SR.7
1=WSM Ready
0=WSM Busy
Check SR.3
1=V
Check SR.1
1=Device Protect Detect
Check SR.4,5
Both 1=Command Sequence Error
Check SR.4
1=Set Lock-Bit Error
Data=70H
Addr=X
Permanent Lock-Bit is Set
(Set Block Lock-Bit Operation)
CCW
F1H(Permanent)
Device Address(Permanent)
Error Detect
Comments
Comments
Rev. 1.27
24

Related parts for LH28F320BJHE-PTTL90