M95640-WBN6 STMicroelectronics, M95640-WBN6 Datasheet - Page 23

no-image

M95640-WBN6

Manufacturer Part Number
M95640-WBN6
Description
Manufacturer
STMicroelectronics
Datasheet

Specifications of M95640-WBN6

Density
64Kb
Interface Type
Serial (SPI)
Organization
8Kx8
Access Time (max)
60ns
Frequency (max)
5MHz
Write Protection
Yes
Data Retention
40Year
Operating Supply Voltage (typ)
3.3/5V
Package Type
PDIP
Operating Temp Range
-40C to 85C
Supply Current
5mA
Operating Supply Voltage (min)
2.5V
Operating Supply Voltage (max)
5.5V
Operating Temperature Classification
Industrial
Mounting
Through Hole
Pin Count
8
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M95640-WBN6
Manufacturer:
ST
0
DC AND AC PARAMETERS
This section summarizes the operating and mea-
surement conditions, and the DC and AC charac-
teristics of the device. The parameters in the DC
and AC Characteristic tables that follow are de-
rived from tests performed under the Measure-
Table 10. Operating Conditions (M95320 and M95640)
Table 11. Operating Conditions (M95320-W and M95640-W)
Table 12. Operating Conditions (M95320-R and M95640-R)
Note: 1. This product is under development. For more information, please contact your nearest ST sales office.
Table 13. Operating Conditions (M95320-S and M95640-S)
Note: 1. This product is under development. For more information, please contact your nearest ST sales office.
Table 14. AC Measurement Conditions
Note: Output Hi-Z is defined as the point where data out is no longer driven.
Symbol
Symbol
Symbol
Symbol
Symbol
V
V
V
V
C
T
T
T
T
CC
CC
CC
CC
A
A
A
A
L
Supply Voltage
Ambient Operating Temperature (Device Grade 6)
Ambient Operating Temperature (Device Grade 3)
Supply Voltage
Ambient Operating Temperature (Device Grade 6)
Ambient Operating Temperature (Device Grade 3)
Supply Voltage
Ambient Operating Temperature
Supply Voltage
Ambient Operating Temperature
Load Capacitance
Input Rise and Fall Times
Input Pulse Voltages
Input and Output Timing Reference Voltages
Parameter
Parameter
Parameter
Parameter
Parameter
ment Conditions summarized in the relevant
tables. Designers should check that the operating
conditions in their circuit match the measurement
conditions when relying on the quoted parame-
ters.
Min.
Min.
Min.
Min.
Min.
1.65
–40
–40
–40
–40
–40
–40
4.5
2.5
1.8
0.2V
0.3V
1
1
CC
CC
Typ.
30
to 0.8V
to 0.7V
Max.
Max.
Max.
Max.
125
125
5.5
5.5
5.5
5.5
85
85
85
85
CC
CC
M95640, M95320
Max.
1
1
50
Unit
Unit
Unit
Unit
°C
°C
°C
°C
°C
°C
Unit
V
V
V
V
pF
ns
V
V
23/42