PKL4316PIT Ericsson Power Modules, PKL4316PIT Datasheet - Page 35

no-image

PKL4316PIT

Manufacturer Part Number
PKL4316PIT
Description
Module DC-DC 1-OUT 28V 11A 310W 11-Pin Half-Brick Tray
Manufacturer
Ericsson Power Modules
Type
Step Downr
Datasheet

Specifications of PKL4316PIT

Package
11Half-Brick
Output Current
11 A
Output Voltage
28 V
Input Voltage
48/60 V
Number Of Outputs
1
Output Power
310 W
Switching Regulator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PKL4316PIT
Manufacturer:
ERICSSON
Quantity:
292
Part Number:
PKL4316PIT
Quantity:
60
Part Number:
PKL4316PITM
Manufacturer:
ERICSSON
Quantity:
38
Part Number:
PKL4316PITM
Manufacturer:
ERICSSON
Quantity:
492
Part Number:
PKL4316PITM
Manufacturer:
ERICSSON/爱立信
Quantity:
20 000
Part Number:
PKL4316PITO
Manufacturer:
ERICSSON
Quantity:
38
Part Number:
PKL4316PITO
Manufacturer:
ERICSSON
Quantity:
726
Thermal Consideration continued
Definition of reference temperature (T
The reference temperature is used to monitor the temperature
limits of the product. Temperatures above maximum T
not allowed and may cause degradation or permanent
damage to the product. T
temperature range for normal operating conditions.
T
margins, proper operation and high reliability of the module.
Ambient Temperature Calculation
By using the thermal resistance the maximum allowed
ambient temperature can be calculated.
1. The power loss is calculated by using the formula
((1/η) - 1) × output power = power losses (Pd).
η = efficiency of converter. E.g 89.5 % = 0.895
2. Find the thermal resistance (Rth) in the Thermal Resistance
graph found in the Output section for each model.
Calculate the temperature increase (ΔT).
3. Max allowed ambient temperature is:
Max Tref - ΔT.
E.g PKL4118B PIT at 2m/s:
1.
2. 25.0 W × 1.3°C/W = 32.5°C
3. 110 °C — 32.5°C = max ambient temperature is 77.5°C
The actual temperature will be dependent on several factors
such as the PCB size, number of layers and direction of
airflow.
ΔT = Rth x Pd
Prepared (also subject responsible if other)
EQUENXU
Approved
SEC/D (Julia You)
PKL 4000 PI series
DC/DC converters, Input 36-75 V, Output 100 A/300 W
ref
((
is defined by the design and used to guarantee safety
0.852
1
) -
1) × 144 W = 25.0 W
ref
is also used to define the
ref
)
Checked
EZYPING
ref
are
Connections
PRODUCT SPECIFICATION
No.
3/1301-BMR 632 Uen
Date
2007-01-11
Pin
5,10
9,11
1
2
3
4
6
7
8
+In
RC
Case
-In
-Out
-Sen
V
+Sen
+Out
Designation
adj
Technical Specifi cation
EN/LZT 146 311 R2E June 2007
© Ericsson Power Modules AB
Rev
B
Positive Input
Remote Control
Connected to baseplate
Negative Input
Negative Output
Negative Sense
Output voltage adjust
Positive Sense
Positive Output
Function
Reference
4 (5)
35

Related parts for PKL4316PIT