G6K2FDC24 Omron, G6K2FDC24 Datasheet - Page 3

G6K2FDC24

Manufacturer Part Number
G6K2FDC24
Description
Manufacturer
Omron
Type
Signal Relayr
Datasheet

Specifications of G6K2FDC24

Relay Construction
Non-Latching
Contact Arrangement
DPDT
Coil Voltage Dc
24V
Coil Current
4.6mA
Contact Form
2 Form C
Voltage Rating (vdc)
60V
Voltage Rating (vac)
125V
Dropout Volt (min)
2.4VDCV
Coil Resistance
5.22kohm
Pick-up Voltage (max)
19.2VDC
Maximum Power Rating
30W/37.5VA
Operate Time
3ms
Contact Current Rating
1A
Contact Material
Ag/Au
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Unsealed
Product Height (mm)
5.2mm
Product Depth (mm)
7.8mm
Product Length (mm)
10mm
Operating Temp Range
-40C to 70C
Pin Count
8
Mounting Style
Surface Mount
Termination Style
Gull Wing
Lead Free Status / Rohs Status
Compliant
■ Characteristic data
Shock Malfunction
Maximum Switching Capacity
Shock direction
Electrical Service Life
Conditions:
DC resistive load
125 VAC resistive load
Ambient temperature: 23°C
Switching frequency:
1,800 operations/hour
Rated operating voltage (V)
Rated operating current (A)
Shock is applied in ±X, ±Y, and ±Z di
rections three times each with and with
out energizing the Relays to check the
number of contact malfunctions.
30 VDC resistive load
Ambient temperature: 23°C
Switching frequency:
1,800 operations/hour
AC resistive load
Not
energized
Unit: m/s
Sample: G6K-2G
Number of Relays: 10
Energized
2
Note: The maximum coil voltage refers to the maxi-
Electrical Service Life
(with Must Operate and Must
Release Voltage) (See note.)
G6K-2G (F/P), G6K-2G (F/P)-Y
Ambient Temperature vs.
Maximum Coil Voltage
Ambient Temperature vs. Must
Operate or Must Release Voltage
G6K-2G (F/P), G6K-2G (F/P)-Y
mum value in a varying range of operating
power voltage, not a continuous voltage.
Operating frequency (x10 operations)
Note: The tests were conducted at an
Must operate
Sample: G6K-2G
Number of Relays: 10
Test conditions: 1 A resistive load at
30 VDC with an operation rate of 50%
Switching frequency: 1,800 operations/h
Must release
ambient temperature of 23°C.
Ambient temperature (°C)
Ambient temperature (°C)
Max. estimated value
3
Operate voltage
Release voltage
Electrical Service Life
(Contact Resistance) (See note.)
G6K-2G (F/P), G6K-2G (F/P)-Y
Ambient Temperature vs.
Switching Current
Ambient Temperature vs. Must
Set or Must Reset Voltage
G6KU-2G (F/P)-Y
Low Signal Relay
Operating frequency (x10
Note: The tests were conducted at an
Switching frequency: 1,800 operations/h
Sample: G6K-2G
Number of Relays: 10
Test conditions: 1 A resistive load
at 30 VDC with an operation rate of 50%
Contact resistance
ambient temperature of 23°C.
Ambient temperature (°C)
Ambient temperature (°C)
Max. estimated value
G6K
3
operations)
NO
contact
NC
contact
69