PIC10F206-I/OT Microchip Technology, PIC10F206-I/OT Datasheet - Page 57

no-image

PIC10F206-I/OT

Manufacturer Part Number
PIC10F206-I/OT
Description
MCU 8-Bit PIC10 PIC RISC 768Byte Flash 2.5V/3.3V/5V 6-Pin SOT-23 Bag
Manufacturer
Microchip Technology
Datasheet

Specifications of PIC10F206-I/OT

Package
6SOT-23
Device Core
PIC
Family Name
PIC10
Maximum Speed
4 MHz
Ram Size
24 Byte
Program Memory Size
768 Byte
Operating Supply Voltage
2.5|3.3|5 V
Data Bus Width
8 Bit
Program Memory Type
Flash
Number Of Programmable I/os
3
Operating Temperature
-40 to 85 °C
Number Of Timers
1

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PIC10F206-I/OT
Manufacturer:
MICROC
Quantity:
28 000
Part Number:
PIC10F206-I/OT
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
DECF
Syntax:
Operands:
Operation:
Status Affected: Z
Description:
DECFSZ
Syntax:
Operands:
Operation:
Status Affected: None
Description:
GOTO
Syntax:
Operands:
Operation:
Status Affected: None
Description:
© 2007 Microchip Technology Inc.
Decrement f
[ label ] DECF f,d
0 ≤ f ≤ 31
d ∈ [0,1]
(f) – 1 → (dest)
Decrement register ‘f’. If ‘d’ is ‘0’,
the result is stored in the W
register. If ‘d’ is ‘1’, the result is
stored back in register ‘f’.
Decrement f, Skip if 0
[ label ] DECFSZ f,d
0 ≤ f ≤ 31
d ∈ [0,1]
(f) – 1 → d;
The contents of register ‘f’ are
decremented. If ‘d’ is ‘0’, the result
is placed in the W register. If ‘d’ is
‘1’, the result is placed back in
register ‘f’.
If the result is ‘0’, the next instruc-
tion, which is already fetched, is
discarded and a NOP is executed
instead making it a two-cycle
instruction.
Unconditional Branch
[ label ]
0 ≤ k ≤ 511
k → PC<8:0>;
STATUS<6:5> → PC<10:9>
GOTO is an unconditional branch.
The 9-bit immediate value is
loaded into PC bits <8:0>. The
upper bits of PC are loaded from
STATUS<6:5>. GOTO is a two-
cycle instruction.
GOTO k
skip if result = 0
PIC10F200/202/204/206
INCF
Syntax:
Operands:
Operation:
Status Affected: Z
Description:
INCFSZ
Syntax:
Operands:
Operation:
Status Affected: None
Description:
IORLW
Syntax:
Operands:
Operation:
Status Affected: Z
Description:
Increment f
[ label ]
0 ≤ f ≤ 31
d ∈ [0,1]
(f) + 1 → (dest)
The contents of register ‘f’ are
incremented. If ‘d’ is ‘0’, the result
is placed in the W register. If ‘d’ is
‘1’, the result is placed back in
register ‘f’.
[ label ]
0 ≤ f ≤ 31
d ∈ [0,1]
(f) + 1 → (dest), skip if result = 0
The contents of register ‘f’ are
incremented. If ‘d’ is ‘0’, the result
is placed in the W register. If ‘d’ is
‘1’, the result is placed back in
register ‘f’.
If the result is ‘0’, then the next
instruction, which is already
fetched, is discarded and a NOP is
executed instead making it a
two-cycle instruction.
Inclusive OR literal with W
[ label ]
0 ≤ k ≤ 255
(W) .OR. (k) → (W)
The contents of the W register are
OR’ed with the eight-bit literal ‘k’.
The result is placed in the W
register.
Increment f, Skip if 0
INCF f,d
INCFSZ f,d
IORLW k
DS41239D-page 55

Related parts for PIC10F206-I/OT