V24A5M400AN Vicor Corporation, V24A5M400AN Datasheet

no-image

V24A5M400AN

Manufacturer Part Number
V24A5M400AN
Description
Manufacturer
Vicor Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
V24A5M400AN
Manufacturer:
VICOR
Quantity:
78
Part Number:
V24A5M400AN
Manufacturer:
VICOR
Quantity:
452
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
These DC-DC converter modules use
advanced power processing, control and
packaging technologies to provide the
performance, flexibility, reliability and cost
effectiveness of a mature power component.
High frequency ZCS/ZVS switching
provides high power density with low
noise and high efficiency.
Industrial and process control, distributed
power, medical, ATE, communications,
defense, aerospace
e.g. V24A12T400BL2
Output Voltage
3 V 3 = 3.3 V
RoHS Compliant (with F or G pin option)
DC input range: 18 – 36 V
Input surge withstand: 50 V for 100 ms
DC output: 3.3 – 48 V
Programmable output: 10 to 110%
Regulation: ±0.25% no load to full load
Efficiency: Up to 88%
Maximum operating temp: 100°C, full load
Power density: up to 80 W per cubic inch
Height above board: 0.43 in. (10,9 mm)
Parallelable, with N+M fault tolerance
Low noise ZCS/ZVS architecture
12 = 12 V
15 = 15 V
24 = 24 V
28 = 28 V
36 = 36 V
48 = 48 V
5 = 5 V
8 = 8 V
Grade Operating
E =
C =
H =
M =
T =
Product Grade Temperatures (°C)
-
-
-
-
-
10 to +100
20 to +100
40 to +100
40 to +100
55 to +100
Set your site on VICOR at www.vicorpower.com
V24A
-
-
-
-
-
Storage
20 to +125
40 to +125
40 to +125
55 to +125
65 to +125
24V Input Maxi Family
Vout
3.3 V
5 V
8 V
12 V
15 V
24 V
28 V
36 V
48 V
117 x 56 x 12,7 mm
+In to –In voltage
PC to –In voltage
PR to –In voltage
SC to -Out voltage
-Sense to -Out voltage
+Out to -Out, +Sense to -Out
Isolation voltage
Operating Temperature
Storage Temperature
Pin soldering temperature
Mounting torque
Shown actual size:
4.6 x 2.2 x 0.5 in
in to out
in to base
out to base
Output Power
Pout
264 W, 200 W
400 W, 300 W
300 W
400 W, 300 W
400 W, 300 W
400 W, 300 W
400 W, 300 W
400 W, 300 W
400 W, 300 W
B
24V Maxi Family
Pin Style
Blank: Short Tin/Lead
L: Long Tin/Lead
S: Short ModuMate
N: Long ModuMate
F: Short RoHS
G: Long RoHS
-0.5 to +7.0
-0.5 to +7.0
-0.5 to +1.5
-55 to +100
-65 to +125
-0.5 to +53
500 (260)
750 (390)
5 (0.57)
3000
1500
500
1.0
Baseplate
Blank: Slotted
2: Threaded
3: Through-hole
in-lbs (N-m)
°F (°C)
°F (°C)
Vrms
Vrms
Vrms
Vdc
Vdc
Vdc
Vdc
Vdc
°C
°C
For a description of pin
options, see page 11.
Baseplate options include
slotted flanges, threaded
and through-hole.
See page 12 for dimensions.
For other package sizes and
power levels, see the Mini
(half size) and Micro
(quarter size) datasheets.
Rev. 4.2
See Module Output
Specifications
Test voltage
Test voltage
Test voltage
M-Grade
M-Grade
<5 sec; wave solder
<7 sec; hand solder
6 each
Page 1 of 13

Related parts for V24A5M400AN

V24A5M400AN Summary of contents

Page 1

RoHS Compliant (with pin option) DC input range: 18 – Input surge withstand for 100 ms DC output: 3.3 – Programmable output 110% Regulation: ±0.25% no load to full ...

Page 2

Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate. Operating input voltage 18 Input surge withstand ...

Page 3

Primary Control Parallel) PC bias voltage 5.50 current limit 1.5 PC module disable 2.3 PC module enable delay PC module alarm PR emitter amplitude 5.7 PR emitter current 150 PR receiver impedance 375 PR receiver threshold ...

Page 4

Efficiency 75.5 Ripple and noise Output OVP setpoint 4.14 Dissipation, standby Load regulation Load current 0 Current limit 81.6 Short circuit current 56 Efficiency 73.9 Ripple and noise Output OVP setpoint 4.48 Dissipation, standby Load regulation Load current 0 Current ...

Page 5

Efficiency 85 Ripple and noise Output OVP setpoint 13.7 Dissipation, standby Load regulation Load current 0 Current limit 34 Short circuit current 23.3 Efficiency 86 Ripple and noise Output OVP setpoint 13.7 Dissipation, standby Load regulation Load current 0 Current ...

Page 6

Efficiency 86.8 Ripple and noise Output OVP setpoint 27.1 Dissipation, standby Load regulation Load current 0 Current limit 12.7 Short circuit current 8.75 Efficiency 86 Ripple and noise Output OVP setpoint 31.5 Dissipation, standby Load regulation Load current 0 Current ...

Page 7

Efficiency 84.7 Ripple and noise Output OVP setpoint 53.8 Dissipation, standby Load regulation Load current 0 Current limit 8.49 Short circuit current 4.79 Efficiency 86 Ripple and noise Output OVP setpoint 53.7 Dissipation, standby Load regulation Load current 0 Current ...

Page 8

The module may be disabled by pulling PC below 2.3 V with respect to the –Input. This may be done with an open collector transistor, relay, or optocoupler. Multiple converters may be disabled with a single transistor or relay either ...

Page 9

The output voltage of the converter can be adjusted or programmed via fixed resistors, potentiometers or voltage DACs. See Figures 7 and 8. +OUT +S Error SC Amp –S 0.033 μF 1 kΩ –OUT 1.23 V 1,000 Vout R (ohms) ...

Page 10

The PR pin supports paralleling for increased power with N+1 (N+M) redundancy and phased array capability. Modules of the same input voltage, output voltage, and power level will current share if all PR pins are suitably interfaced. Compatible interface architectures ...

Page 11

Module 1 SC –S –S –OUT +S +OUT +S +S Module 2 Load SC –S –S –OUT –S +OUT +S Module N+1 SC –S –OUT Figure 11 — N+1 module array output connections. (None) Short Tin/Lead L ...

Page 12

No. Function Label 1 +In + 0.300±0.015 7,62±0,38 Primary 2 PC 0.23 Control (REF) 5,8 3 Parallel PR Pin –In – 0.300±0.015 7,62±0,38 5 –Out – 6 –Sense –S Secondary 7 SC Control 8 +Sense +S 9 ...

Page 13

Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal use and service. This warranty does not extend to products subjected to misuse, accident, or improper application or maintenance. Vicor ...

Related keywords