UPD4990A NEC, UPD4990A Datasheet

no-image

UPD4990A

Manufacturer Part Number
UPD4990A
Description
SERIAL I/O CALENDAR & CLOCK CMOS LSI
Manufacturer
NEC
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD4990A
Manufacturer:
CAT
Quantity:
6 226
Part Number:
UPD4990A
Manufacturer:
NEC
Quantity:
20 000
Part Number:
UPD4990AC
Manufacturer:
NEC
Quantity:
5 510
Part Number:
UPD4990AC
Manufacturer:
CRY
Quantity:
5 510
Part Number:
UPD4990AC
Manufacturer:
NEC
Quantity:
20 000
Part Number:
UPD4990AG
Manufacturer:
NEC
Quantity:
20 000
Part Number:
UPD4990AG-A
Manufacturer:
NEC
Quantity:
2 500
Part Number:
UPD4990AG-E2
Quantity:
2 614
Part Number:
UPD4990AG-E2
Manufacturer:
NEC
Quantity:
20 000
Part Number:
UPD4990AG-T1
Manufacturer:
NEC
Quantity:
20 000
Company:
Part Number:
UPD4990AG-T1
Quantity:
1 453
Document No. IC-1755 (1st edition)
Date Published March 1997 P
Printed in Japan
week.
FEATURES
ORDERING INFORMATION
CONNECTION DIAGRAM (Top View)
DATA IN
The PD4990A is a CMOS LSI developed to input/output calendar & clock data serially to/from the micro computer.
The crystal frequency is 32.768 kHz and the data items included are time, minute, second, year, month, day, and
Built-in counters for time (hour, minute, and second) and date (year, month, day, and week)
Leap years are adjusted automatically.
Data is represented in BCD notation (except months in hexadecimal notation) and input/output serially.
Commands can be set by inputting serial data.
Selective timing pulses (TPs) are 64 Hz, 256 Hz, 2 048 Hz, and 4 096 Hz and selective output intervals are 1, 10,
30, and 60 seconds.
GND
(V
PART No.
PD4990AG
STB
PD4990AC
CS
SS
C
C
C
2
1
0
)
1
2
3
4
5
6
7
PD4990AC
14-pin plastic DIP (300 mil)
16-pin plastic SOP (300 mil)
SERIAL I/O CALENDAR & CLOCK
14
13
12
11
10
9
8
PACKAGE
V
X
X
OUT ENBL
TP
DATA OUT
CLK
DD
TAL
TAL
(+)
DATA SHEET
CMOS LSI
MOS INTEGRATED CIRCUIT
DATA IN
GND
(V
STB
NC
CS
SS
C
C
C
2
1
0
)
NC: NO CONNECTION
1
2
3
4
5
6
7
8
PD4990A
PD4990AG
16
15
14
13
12
11
10
9
©
V
X
X
NC
OUT ENBL
TP
DATA OUT
CLK
DD
TAL
TAL
(+)
1989

Related parts for UPD4990A

UPD4990A Summary of contents

Page 1

... Commands can be set by inputting serial data. • Selective timing pulses (TPs) are 64 Hz, 256 Hz, 2 048 Hz, and 4 096 Hz and selective output intervals are 1, 10, 30, and 60 seconds. ORDERING INFORMATION PART No. PD4990AC 14-pin plastic DIP (300 mil) PD4990AG 16-pin plastic SOP (300 mil) CONNECTION DIAGRAM (Top View ...

Page 2

ABSOLUTE MAXIMUM RATINGS Supply Voltage Input Voltage Operating Temperature Range Storage Temperature Range Output Terminal Voltage ELECTRICAL CHARACTERISTICS (f = 32.768 kHz, C CHARACTERISTIC SYMBOL Operating Voltage Current Consumption I DD Low Level Output Voltage V OL ...

Page 3

OE CLK CLK DATA COMMAND IN Register CLK TAL OSC X TAL Select signal generator circuit ...

Page 4

... Each command is latched with STB (strobe). Chip select Connecting the CS pin to the ground level inhibits CLK and STB inputs. Data output inhibition Connecting the OUT ENBL pin to the ground level sets the DATA OUT pin at high impedance. MSB command Ten's of Unit of ...

Page 5

TERMINALS Input terminals DATA IN Data input of 40-/52-bit shift register CLK Shift clock input of 40-/52-bit shift register Command input (3 bit STB Strobe input CS Chip select input (Prohibits CLK ...

Page 6

... interval set (counter reset & start interval set (counter reset & start interval set (counter reset & start interval set (counter reset & start) Interval Output Flag Reset Interval Timer Clock Run Interval Timer Clock Stop TEST MODE SET , C , and C pins should be connected PD4990A pin. DD ...

Page 7

Command input (1) 3-bit binary code input (2) 4-bit serial transfer command input: C Number of commands Register control TP select TP control Test mode set Commands ( ...

Page 8

TP selection and control [ Set Mode [ [ (50 % duty) is output to the TP pin The year ...

Page 9

Interval output function An interrupt signal can be output by selecting an output from TP. Interrupt signals are output repeatedly at specified intervals until their output is suppressed by a command. Only output flags can be reset to operate the ...

Page 10

Test mode In the test mode, data is output to the DATA OUT pin regardless of whether data has been input to OUT ENBL. There are two different test modes depending on the OUT ENBL data. (1) Test mode 1 ...

Page 11

TIMING DIAGRAM FOR SETTING COMMANDS ( DATA DSU V IH CLK V IL STB Other than time read mode NEW COMMAND OLD MODE VALID Time read mode OLD MODE V ...

Page 12

TIMING DIAGRAM FOR SETTING COMMANDS (C CAN CHANGE STB CLK V IL Other than time read mode NEW COMMAND OLD MODE VALID Time read mode OLD MODE V ...

Page 13

DATA INPUT/OUTPUT TIMING DIAGRAM CLK "1" s. "10" s. DATA IN OUT ENBL "1" s. "10" s. DATA OUT 1011 Note: Reading-in timing of CPU (Trailing edge of CLK). TIMING ...

Page 14

POWER SUPPLY CIRCUIT 1SS53 2SA733 + 510 2SC945 4.7 k GND 14 PD4990A 1SS53 DIN Ni Cd CLK 3.6 V STB TAL ...

Page 15

APPLICATION + CLK RESET PD4175BC Power Supply Circuit 10 k DATA BUS WR ...

Page 16

PLASTIC DIP (300 mil NOTES 1) Each lead centerline is located within 0.25 mm (0.01 inch) of its true position (T.P.) at maximum material condition. 2) Item "K" to ...

Page 17

PIN PLASTIC SOP (300 mil NOTE Each lead centerline is located within 0.12 mm (0.005 inch) of its true position (T.P.) at maximum material condition PD4990A detail of ...

Page 18

PD4990A ...

Page 19

PD4990A 19 ...

Page 20

... Specific: Aircrafts, aerospace equipment, submersible repeaters, nuclear reactor control systems, life support systems or medical equipment for life support, etc. The quality grade of NEC devices is "Standard" unless otherwise specified in NEC's Data Sheets or Data Books. If customers intend to use NEC devices for applications other than those specified for Standard quality grade, they should contact an NEC sales representative in advance ...

Related keywords