Specifications of AT80C51RD2

Max. Operating Frequency
60 MHz
Cpu
8051-12C
Max I/o Pins
32
Spi
1
Uart
1
Sram (kbytes)
1.25
Operating Voltage (vcc)
2.7 to 5.5
Timers
4
Watchdog
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT80C51RD2-RLRUM
Manufacturer:
NXP
Quantity:
8 243
Part Number:
AT80C51RD2-RLRUM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT80C51RD2-RLTIM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT80C51RD2-RLTUM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT80C51RD2-SLRUM
Manufacturer:
Atmel
Quantity:
967
Part Number:
AT80C51RD2-SLRUM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT80C51RD2-SLSIM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT80C51RD2-SLSUM
Manufacturer:
Atmel
Quantity:
1 445
Part Number:
AT80C51RD2-UM
Manufacturer:
FAIRCHIL
Quantity:
550
Figure 10-5. PCA High-speed Output Mode
10.4
32
Pulse Width Modulator Mode
CCAPnH
AT80C51RD2
Write to
1
CCA PnL
Write to
0
Before enabling ECOM bit, CCAPnL and CCAPnH should be set with a non zero value, other-
wise an unwanted match could occur.
Once ECOM is set, writing CCAPnL will clear ECOM so that an unwanted match doesn’t occur
while modifying the compare value. Writing to CCAPnH will set ECOM. For this reason, user
software should write CCAPnL first, and then CCAPnH. Of course, the ECOM bit can still be
controlled by accessing the CCAPMn register.
All of the PCA modules can be used as PWM outputs. Figure 10-6 shows the PWM function.
The frequency of the output depends on the source for the PCA timer. All of the modules will
have the same frequency of output because they all share the PCA timer. The duty cycle of each
module is independently variable using the module's capture register CCAPLn. When the value
of the PCA CL SFR is less than the value in the module's CCAPLn SFR the output will be low,
when it is equal to or greater than the output will be high. When CL overflows from FF to 00,
CCAPLn is reloaded with the value in CCAPHn. This allows updating the PWM without glitches.
The PWM and ECOM bits in the module's CCAPMn register must be set to enable the PWM
mode.
Reset
Enable
PCA counter/timer
CCAPnH
CH
16 bit comparator
CF
ECOMn
CCAPnL
CR
CL
CAPPn
Match
CAPNn MATn TOGn PWMn ECCFn
CCF4 CCF3 CCF2 CCF1 CCF0
CCON
0xD8
CCAPMn, n = 0 to 4
0xDA to 0xDE
PCA IT
CEXn
4113D–8051–01/09