SAM3N1A Atmel Corporation, SAM3N1A Datasheet - Page 500

no-image

SAM3N1A

Manufacturer Part Number
SAM3N1A
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM3N1A

Flash (kbytes)
64 Kbytes
Pin Count
48
Max. Operating Frequency
48 MHz
Cpu
Cortex-M3
# Of Touch Channels
17
Hardware Qtouch Acquisition
No
Max I/o Pins
34
Ext Interrupts
34
Quadrature Decoder Channels
2
Usb Speed
No
Usb Interface
No
Spi
2
Twi (i2c)
2
Uart
3
Ssc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
8
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
no / no
Timers
6
Output Compare Channels
6
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
1 = In read mode, a data byte has not been acknowledged by the Master. When NACK is set the programmer must not fill
TWI_THR even if TXRDY is set, because it means that the Master will stop the data transfer or re initiate it.
Note that in Slave Write mode all data are acknowledged by the TWI.
• ARBLST: Arbitration Lost (clear on read)
This bit is only used in Master mode.
0: Arbitration won.
1: Arbitration lost. Another master of the TWI bus has won the multi-master arbitration. TXCOMP is set at the same time.
• SCLWS: Clock Wait State (automatically set / reset)
This bit is only used in Slave mode.
0 = The clock is not stretched.
1 = The clock is stretched. TWI_THR / TWI_RHR buffer is not filled / emptied before the emission / reception of a new
character.
SCLWS behavior can be seen in
• EOSACC: End Of Slave Access (clear on read)
This bit is only used in Slave mode.
0 = A slave access is being performing.
1 = The Slave Access is finished. End Of Slave Access is automatically set as soon as SVACC is reset.
EOSACC behavior can be seen in
• ENDRX: End of RX buffer
This bit is only used in Master mode.
0 = The Receive Counter Register has not reached 0 since the last write in TWI_RCR or TWI_RNCR.
1 = The Receive Counter Register has reached 0 since the last write in TWI_RCR or TWI_RNCR.
• ENDTX: End of TX buffer
This bit is only used in Master mode.
0 = The Transmit Counter Register has not reached 0 since the last write in TWI_TCR or TWI_TNCR.
1 = The Transmit Counter Register has reached 0 since the last write in TWI_TCR or TWI_TNCR.
• RXBUFF: RX Buffer Full
This bit is only used in Master mode.
0 = TWI_RCR or TWI_RNCR have a value other than 0.
1 = Both TWI_RCR and TWI_RNCR have a value of 0.
• TXBUFE: TX Buffer Empty
This bit is only used in Master mode.
0 = TWI_TCR or TWI_TNCR have a value other than 0.
1 = Both TWI_TCR and TWI_TNCR have a value of 0.
500
500
SAM3N
SAM3N
Figure 28-28 on page 487
Figure 28-30 on page 489
and
and
Figure 28-29 on page
Figure 28-31 on page 489
488.
11011A–ATARM–04-Oct-10
11011A–ATARM–04-Oct-10

Related parts for SAM3N1A