AD7142 Analog Devices, AD7142 Datasheet - Page 47

no-image

AD7142

Manufacturer Part Number
AD7142
Description
Programmable Controller for Capacitance Touch Sensors
Manufacturer
Analog Devices
Datasheet

Specifications of AD7142

Resolution (bits)
16bit
# Chan
14
Sample Rate
250kSPS
Interface
I²C/Ser 2-Wire,Ser,SPI
Analog Input Type
Diff-Uni
Ain Range
± 2 pF (Delta C)
Adc Architecture
Sigma-Delta
Pkg Type
CSP

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7142ACPZ-1
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7142ACPZ-1500
Manufacturer:
ADI
Quantity:
10
Part Number:
AD7142ACPZ-1500
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7142ACPZ-1500RL7
Manufacturer:
ADI
Quantity:
8 000
Part Number:
AD7142ACPZ-1REEL
Manufacturer:
NXP
Quantity:
2 007
Table 28. STAGE_HIGH_LIMIT_INT Register
Address
0x009
1
Registers self-clear to 0 after readback, provided that the limits are not exceeded.
Data Bit
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[11]
[15:12]
Default Value
0
0
0
0
0
0
0
0
0
0
0
0
Type
R
1
Name
STAGE0_HIGH_LIMIT_INT
STAGE1_HIGH_LIMIT_INT
STAGE2_HIGH_LIMIT_INT
STAGE3_HIGH_LIMIT_INT
STAGE4_HIGH_LIMIT_INT
STAGE5_HIGH_LIMIT_INT
STAGE6_HIGH_LIMIT_INT
STAGE7_HIGH_LIMIT_INT
STAGE8_HIGH_LIMIT_INT
STAGE9_HIGH_LIMIT_INT
STAGE10_HIGH_LIMIT_INT
STAGE11_HIGH_LIMIT_INT
Unused
Rev. A | Page 47 of 72
STAGE0 CDC conversion high limit interrupt result
Description
STAGE1 CDC conversion high limit interrupt result
Stage2 CDC conversion high limit interrupt result
STAGE3 CDC conversion high limit interrupt result
STAGE4 CDC conversion high limit interrupt result
STAGE5 CDC conversion high limit interrupt result
STAGE6 CDC conversion high limit interrupt result
STAGE7 CDC conversion high limit interrupt result
STAGE8 CDC conversion high limit interrupt result
STAGE9 CDC conversion high limit interrupt result
STAGE10 CDC conversion high limit interrupt result
STAGE11 CDC conversion high limit interrupt result
Set unused register bits = 0
1 = indicates STAGE0_HIGH_THRESHOLD value was
exceeded
1 = indicates STAGE1_HIGH_THRESHOLD value was
exceeded
1 = indicates STAGE2_HIGH_THRESHOLD value was
exceeded
1 = indicates STAGE3_HIGH_THRESHOLD value was
exceeded
1 = indicates STAGE4_HIGH_THRESHOLD value was
exceeded
1 = indicates STAGE5_HIGH_THRESHOLD value was
exceeded
1 = indicates STAGE6_HIGH_THRESHOLD value was
exceeded
1 = indicates STAGE7_HIGH_THRESHOLD value was
exceeded
1 = indicates STAGE8_HIGH_THRESHOLD value was
exceeded
1 = indicates STAGE9_HIGH_THRESHOLD value was
exceeded
1 = indicates STAGE10_HIGH_THRESHOLD value was
exceeded
1 = indicates STAGE11_HIGH_THRESHOLD value was
exceeded