AD7940 Analog Devices, AD7940 Datasheet - Page 18

no-image

AD7940

Manufacturer Part Number
AD7940
Description
3 mW, 100 kSPS, 14-Bit ADC in 6-Lead SOT-23
Manufacturer
Analog Devices
Datasheet

Specifications of AD7940

Resolution (bits)
14bit
# Chan
1
Sample Rate
100kSPS
Interface
Ser,SPI
Analog Input Type
SE-Uni
Ain Range
Uni Vdd
Adc Architecture
SAR
Pkg Type
SOP,SOT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7940BRJZ-REEL7
Manufacturer:
ADI
Quantity:
1 000
Part Number:
AD7940BRM
Quantity:
200
Part Number:
AD7940BRMZ
Manufacturer:
ADI
Quantity:
1 000
Part Number:
AD7940BRMZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7940BRMZ-REEL7
Manufacturer:
ADI
Quantity:
1 000
For example, if the ADSP-2189 had a 20 MHz crystal, such that
it had a master clock frequency of 40 MHz, the master cycle
time would be 25 ns. If the SCLKDIV register is loaded with the
value 7, then a SCLK of 2.5 MHz is obtained, and 16 master
clock periods will elapse for every 1 SCLK period. Depending
on the throughput rate selected, if the timer register was loaded
with the value 803 (803 + 1 = 804), then 50.25 SCLKs will occur
between interrupts and subsequently between transmit
instructions. This situation will result in nonequidistant sampling
since the transmit instruction is occurring on a SCLK edge. If the
number of SCLKs between interrupts is a whole integer figure of N,
then equidistant sampling will be implemented by the DSP.
Rev. A | Page 18 of 20
AD7940 TO DSP563xx
The connection diagram in Figure 23 shows how the AD7940
can be connected to the ESSI (synchronous serial interface) of
the DSP-563xx family of DSPs from Motorola. Each ESSI (two
on board) is operated in synchronous mode (SYN bit in CRB =
1) with internally generated 1-bit clock period frame sync for
both Tx and Rx (Bits FSL1 = 0 and FSL0 = 0 in CRB). Normal
operation of the ESSI is selected by making MOD = 0 in the
CRB. Set the word length to 16 by setting bits WL1 = 1 and
WL0 = 0 in CRA. The FSP bit in the CRB should be set to 1 so
that the frame sync is negative. It should be noted that for signal
processing applications, it is imperative that the frame
synchronization signal from the DSP-563xx provide equidistant
sampling.
In the example shown in Figure 23, the serial clock is taken from
the ESSI so the SCK0 pin must be set as an output, SCKD = 1.
*ADDITIONAL PINS OMITTED FOR CLARITY
AD7940*
Figure 23. Interfacing to the DSP-563xx
DOUT
SCLK
CS
SCK
SRD
STD
DSP-563xx*
AD7940