ADP8861 Analog Devices, ADP8861 Datasheet - Page 25

no-image

ADP8861

Manufacturer Part Number
ADP8861
Description
Charge Pump, 7-Channel Smart LED Driver with I2C Interface
Manufacturer
Analog Devices
Datasheet

Specifications of ADP8861

Vin Range
2.5 to 5.5V
Vout (v)
4.3 to 5.5
Synchronous
No
Package
20-Lead LFCSP,20-Lead WLCSP
Led Configuration
Parallel
Topology
Capacitive
I2c Support
Yes
Max Iout (ma)
60mA
Brightness Control
PWM
Peak Efficiency (%)
89%
Switching Frequency
1.32MHz
Over Volt Protection (v)
5.8V

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADP8861ACPZ-R7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Mode Control Register 2 (MDCR2)—Register 0x02
Table 12. MDCR2 Bit Map
Bit 7
Table 13. Bit Descriptions for the MDCR2 Register
Bit Name
N/A
SHORT_INT
TSD_INT
OVP_INT
N/A
1
Interrupt Enable (INTR_EN)—Register 0x03
Table 14. INTR_EN Bit Map
Bit 7
Table 15. Bit Descriptions for the INTR_EN Register
Bit Name
N/A
SHORT_IEN
TSD_IEN
OVP_IEN
N/A
Interrupt bits are cleared by writing a 1 to the flag; writing a 0 or reading the flag has no effect.
Bit 6
Reserved
Bit No.
[7:5]
4
3
2
[1:0]
Bit 6
Reserved
Bit No.
[7:5]
4
3
2
1:0
Description
Reserved.
Short-circuit interrupt is enabled. When the SHORT_INT status bit is set after an error condition, an interrupt is
raised to the host if the SHORT_IEN flag is enabled.
1 = the short-circuit interrupt is enabled.
0 = the short-circuit interrupt is disabled (the SHORT_INT flag continues to assert).
Thermal shutdown interrupt is enabled. When the TSD_INT status bit is set after an error condition, an interrupt is
raised to the host if the TSD_IEN flag is enabled.
1 = the thermal shutdown interrupt is enabled.
0 = the thermal shutdown interrupt is disabled (the TSD_INT flag continues to assert).
Overvoltage interrupt enabled. When the OVP_INT status bit is set after an error condition, an interrupt is raised to
the host if the OVP_IEN flag is enabled.
1 = the overvoltage interrupt is enabled.
0 = the overvoltage interrupt is disabled (the OVP_INT flag continues to assert).
Reserved.
Bit 5
Bit 5
Description
Reserved
Short-circuit error interrupt.
1 = a short-circuit or overload condition on VOUT has been detected.
0 = no short-circuit or overload condition has been detected.
Thermal shutdown interrupt.
1 = the device temperature has exceeded 150°C (typical).
0 = no overtemperature condition has been detected.
Overvoltage interrupt.
1 = VOUT has exceeded V
0 = VOUT has not exceeded V
Reserved.
Bit 4
SHORT_IEN
Bit 4
SHORT_INT
1
OVP
Rev. A | Page 25 of 40
.
Bit 3
TSD_IEN
OVP
.
Bit 3
TSD_INT
Bit 2
OVP_IEN
Bit 2
OVP_INT
Bit 1
Bit 1
Reserved
Reserved
Bit 0
ADP8861
Bit 0

Related parts for ADP8861