2-640426-4 TE Connectivity, 2-640426-4 Datasheet
2-640426-4
Specifications of 2-640426-4
Related parts for 2-640426-4
2-640426-4 Summary of contents
Page 1
... Post: Brass, post tin plated • Receptacle: Phosphor bronze, post tin plated ! Housing: • 2 through 10 position: Nylon 6/6, UL94V-2 • 11 through 24 position: Nylon 6/12, UL94V-2 3.3. Ratings ! Current/Voltage: 600 volts amperes maximum The maximum rated current that can be carried by this product is limited by the NOTE maximum operating temperature of the housings (105° ...
Page 2
... TE Spec 109-45-2. Temperature rise at rated current. TE Spec 109-51, Condition B, Test Method 2. Subject samples to 15 minutes ON and 15 minutes OFF at 125% of rated current. TE Spec 109-16. Determine slot tensile at a rate of 1 inch per minute. Apply force parallel to axis of wire ...
Page 3
... Tensile, perpendicular. Vibration. Durability. Contact retention. Mating force. Unmating force. Thermal shock. Humidity-temperature cycling. Shall meet visual requirements, show no physical damage, and shall meet requirements of NOTE additional tests as specified in the Test Sequence in Figure 2. Rev F Requirement Wire Size Slot Tensile (AWG) (Lb minimum ...
Page 4
... Numbers indicate sequence in which tests are performed. (c) One half of the samples shall be subjected to the straight tensile test and the remaining half to the perpendicular tensile test. Rev F Test Group ( Test Sequence (b) 1 2,4 2,4 1,3 2,5 1 Figure 2 108-1065 1 ...
Page 5
... Sheets and shall be selected at random from current production. Test group 1 shall consist of 1 connector of each size, all representative of the entire lot being tested. Test groups 2 through 6 shall consist of 2 connector assemblies per group per wire size. Test group 7 shall consist of 15 contacts chosen randomly from 5 connector assemblies. Test group 8 shall consist of 4 connector assemblies per wire size. Each wire size shall consist of solid, stranded and prefused or overcoated wire ...
Page 6
... A 1 foot minimum length of continuous lead for heat dissipation. NOTE 2. Termination resistance equals millivolts divided by test current less resistance of 6 inches of wire. Temperature and Resistance Measurement Points Rev F Figure 3 108-1065 ...
Page 7
... Rev F Figure 4 Terminal Temperature vs Current/Circuit 24 Circuit Assembly 108-1065 ...