1-794511-1 TE Connectivity, 1-794511-1 Datasheet
1-794511-1
Specifications of 1-794511-1
Related parts for 1-794511-1
1-794511-1 Summary of contents
Page 1
... All inspections shall be performed using the applicable inspection plan and product drawing. 1.3. Qualification Test Results Successful qualification testing on the subject product line was completed on 01May98. The test file number for this testing is CTL 8221-000-004A. This documentation is on file at and available from the Americas Regional Laboratory. 2. APPLICABLE DOCUMENTS The following documents form a part of this specification to the extent specified herein ...
Page 2
... Performance and Test Description Product is designed to meet the electrical, mechanical and environmental performance requirements specified in Figure 1. Unless otherwise specified, all tests shall be performed at ambient environmental conditions per Test Specification 109-1. 3.5. Test Requirements and Procedures Summary Test Description Examination of product. Termination resistance. ...
Page 3
... Figure 1 (end) 108-1699 Procedure TE Spec 109-42, Condition A. Measure force necessary to unmate samples with locking latches disengaged at a maximum rate of 12.7 mm [0.5 inch] per minute. TE Spec 109-22. Subject unmated samples to 5 cycles between -55 and 105° Spec 109-23-3, Condition B. Subject mated and unmated samples to 10 cycles between 25 and 65° ...
Page 4
... Thermal shock Humidity-temperature cycling Temperature life (a) See paragraph 4.1.A. NOTE (b) Numbers indicate sequence in which tests are performed. (c) Discontinuities shall not be measured. Energize at 18° C level for 100% loadings per Test Specification 109-151. (d) Precondition samples with 10 cycles durability. Rev B Test Group (a) Test or Examination 1 ...
Page 5
... AMP-DUAC socket connector (e.g. 106527 series receptacle housing and 106528 or 106529 series contacts) unless otherwise required by the test procedure. Test group 1 shall be terminated to the maximum wire size. Samples for test groups 1 and 2 shall be mounted on printed circuit board PN 60-469228-1. Samples for test group 3 shall be unmounted and unmated. ...
Page 6
... Multiplication Factor (F) from the above chart and multiply it times the Base rated Current for a single circuit at the maximum ambient operating temperature shown in Figure 3A. Rev B Figure 3A Current Carrying Capability Wire Size AWG 26 24 .45 .59 50 .38 .50 100 .34 .44 Figure 3B Current Rating 108-1699 .72 .86 1 .61 .73 .85 .54 .65 . ...