71M6513 Maxim, 71M6513 Datasheet - Page 29

no-image

71M6513

Manufacturer Part Number
71M6513
Description
The 71M6513 and 71M6513H are highly integrated SoCs with an MPU core, RTC, flash, and LCD driver
Manufacturer
Maxim
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
71M6513-IEL
Manufacturer:
TERIDIA
Quantity:
20 000
Company:
Part Number:
71M6513-IELR/F
Quantity:
1 000
Part Number:
71M6513-IGT
Manufacturer:
MITE
Quantity:
8
Part Number:
71M6513-IGT
Manufacturer:
TERIDIA
Quantity:
20 000
Company:
Part Number:
71M6513-IGT
Quantity:
640
Part Number:
71M6513-IGT/F
Manufacturer:
MAXIM
Quantity:
1 300
Part Number:
71M6513-IGT/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
71M6513-IGT/F
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
71M6513-IGTR/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
71M6513F-IM
Manufacturer:
TERIDIA
Quantity:
20 000
Part Number:
71M6513H-IGT
Manufacturer:
TERIDIAN
Quantity:
1 376
Part Number:
71M6513H-IGT/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
71M6513H-IGTR/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Refreshing the WD Timer: The watchdog timer must be refreshed regularly to prevent the reset request signal from
becoming active. This requirement imposes an obligation on the programmer to issue two instructions. The first instruction
sets WDT and the second instruction sets SWDT. The maximum delay allowed between setting WDT and SWDT is 12 clock
cycles. If this period has expired and SWDT has not been set, WDT is automatically reset, otherwise the watchdog timer is
reloaded with the content of the WDTREL register and WDT is automatically reset. Since the WDT requires exact timing,
firmware needs to be designed with special care in order to avoid unwanted WDT resets. Teridian strongly discourages the
use of the software WDT.
Special Function Registers for the WD Timer
Interrupt Enable 0 Register (IEN0):
Interrupt Enable 1 Register (IEN1):
Note: The remaining bits in the IEN1 register are not used for watchdog control
IEN0.6
IEN1.6
Bit
Bit
Note: The remaining bits in the IEN0 register are not used for watchdog control
A Maxim Integrated Products Brand
MSB
MSB
EXEN2
EAL
Symbol
Symbol
SWDT
WDT
SWDT
WDT
Function
Watchdog timer refresh flag.
Set to initiate a refresh of the watchdog timer. Must be set directly before SWDT is
set to prevent an unintentional refresh of the watchdog timer. WDT is reset by
hardware 12 clock cycles after it has been set.
Function
Watchdog timer start/refresh flag.
Set to activate/refresh the watchdog timer. When directly set after setting WDT, a
watchdog timer refresh is performed. Bit SWDT is reset by the hardware 12 clock
cycles after it has been set.
Table 28: The IEN1 Bit Functions (see also Tables 30/31)
Table 26: The IEN0 Bit Functions (see also Table 32)
Table 27: The IEN1 Register (see also Tables 30/31)
Table 25: The IEN0 Register (see also Table 32)
EX6
ET2
© 2005-2011 Teridian Semiconductor Corporation
EX5
ES0
ET1
EX4
3-Phase Energy Meter IC
EX1
EX3
71M6513/71M6513H
ET0
EX2
DATA SHEET
EX0
LSB
LSB
SEPTEMBER 2011
Page: 29 of 104