NHSB064 Nichia, NHSB064 Datasheet - Page 14

no-image

NHSB064

Manufacturer Part Number
NHSB064
Description
Manufacturer
Nichia
Datasheet

Specifications of NHSB064

Size Lxwxh (mm)
3.5x2.8x2.0
Lumi-nous Inten-sity Typ(cd)
155
Forward Voltage Vf(v) Typ
3.10
Forward Voltage Vf(v) Max
3.50
Directivity (degree)
115
If (ma)
10
Mounting Style
Through Hole

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
NHSB064T-R1
Quantity:
4 000
RELIABILITY
(1) Tests and Results
(2) Failure Criteria
NOTES:
U.S.L. : Upper Specification Limit
Resistance to
Soldering Heat
(Reflow Soldering)
Solderability
(Reflow Soldering)
Thermal Shock
Temperature Cycle
Moisture Resistance
(Cyclic)
High Temperature
Storage
Temperature Humidity
Storage
Low Temperature
Storage
Room Temperature
Operating Life
High Temperature
Operating Life
Temperature Humidity
Operating Life
Low Temperature
Operating Life
Permanence of Marking
Vibration
Free Fall
Electrostatic Discharges
#1
#2
#3
Criteria #
Measurements are performed after allowing the LEDs to return to room temperature.
Test
Forward Voltage(V
Luminous Intensity(I
Forward Voltage(V
Luminous Intensity(I
Solderability
Items
JEITA ED-4701
300 301
JEITA ED-4701
303 303A
JEITA ED-4701
300 307
JEITA ED-4701
100 105
JEITA ED-4701
200 203
JEITA ED-4701
200 201
JEITA ED-4701
100 103
JEITA ED-4701
200 202
JEITA ED-4701
500 501
JEITA ED-4701
400 403
JEITA ED-4701
300 304
Reference
Standard
L.S.L. : Lower Specification Limit
F
F
)
)
V
V
)
)
I
I
I
I
-
F
F
F
F
=10mA
=10mA
=10mA
=10mA
Conditions
T
Precondition: 30°C, 70%RH, 168hr
T
Lead-free Solder(Sn-3.0Ag-0.5Cu)
-40°C to 110°C, 1min dwell,
10sec transfer,
Precondition: 30°C, 70%RH, 168hr
-40°C(30min)~25°C(5min)~
110°C(30min)~25°C(5min)
25°C~65°C~-10°C, 90%RH,
24hr per cycle
T
T
T
T
T
60°C, RH=90%, I
T
Isopropyl Alcohol, 23±5°C,
Dipping Time: 5min
200m/s
4cycles, 4min, each X, Y, Z
3drops from a height of 75cm
HBM, 2kV, 1.5kΩ, 100pF, 3pulses,
alternately positive or negative
sld
sld
A
A
A
A
A
A
=110°C
=60°C, RH=90%
=-40°C
=25°C, I
=85°C, I
=-40°C, I
=260°C, 10sec, 2reflows,
=245±5°C, 5sec,
2
, 100~2000~100Hz,
Test Conditions
F
F
=15mA
=15mA
F
=10mA
>U.S.L.×1.1
<L.S.L.×0.7
>U.S.L.×1.1
<L.S.L.×0.5
Less than 95% solder coverage
F
=10mA
Failure Criteria
NICHIA STS-DA1-2061 <Cat.No.111130>
100cycles
100cycles
10cycles
1000hours
1000hours
1000hours
1000hours
1000hours
1000hours
1000hours
1time
48minutes
Duration
Test
Criteria
Failure
#1
#3
#1
#1
#1
#2
#1
#1
#1
#1
#1
#1
#2
#2
#2
#1
#
Failed/Tested
0/100
0/100
0/100
0/100
0/100
0/100
0/100
0/100
0/100
0/100
Units
0/22
0/22
0/22
0/22
0/10
0/10
13