ADM211 Analog Devices, ADM211 Datasheet
ADM211
Available stocks
Related parts for ADM211
ADM211 Summary of contents
Page 1
... Shutdown and Enable control pins are provided on some of the products. Please refer to Table I. The shutdown function on the ADM211E disables the charge pump and all transmitters and receivers. On the ADM213E the TranZorb is a registered trademark of General Semiconductor Industries, Inc. ...
Page 2
... ADM206E/ADM207E/ADM208E/ADM211E/ADM213E–SPECIFICATIONS (V = 5.0 V 10%, C1–C4 = 0.1 F. All specifications T CC Parameter Operating Voltage Range V Power Supply Current CC Shutdown Supply Current Input Pull-Up Current Input Logic Threshold Low, V INL Input Logic Threshold High, V INH Input Logic Threshold High, V INH CMOS Output Voltage Low ...
Page 3
... ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection. Although the ADM206E/ADM207E/ADM208E/ADM211E/ADM213E features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high-energy electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance degradation or loss of functionality ...
Page 4
... ADM206E/ADM207E/ADM208E/ADM211E/ADM213E OUT OUT OUT OUT ADM206E TOP VIEW (Not to Scale GND C1 C1– C1 +5V TO +10V 0.1 F VOLTAGE 6.3V DOUBLER C1– 12 C2+ 13 +10V TO –10V 0.1 F VOLTAGE 16V INVERTER C2– ...
Page 5
... OUT OUT OUT OUT OUT SHDN ADM211E GND 10 PULL-UP RESISTOR ON EACH CMOS INPUT PULL-DOWN RESISTOR ON EACH RS-232 INPUT 0.1 F OUT OUT EIA/TIA-232 OUTPUTS OUT OUT IN IN EIA/TIA-232 IN INPUTS IN IN ...
Page 6
... OUT EN/EN Receiver Enable (Active High on ADM213E, Active Low on ADM211E); This input is used to enable/disable the receiver outputs. With EN = Low ADM211E (EN = High ADM213E), the receiver outputs are enabled. With EN = High (EN = Low ADM213E), the receiver outputs are placed in a high impedance state. SHDN/SHDN Shutdown Control (Active Low on ADM213E, Active High on ADM211E); Refer to Table II. In shutdown the charge pump is disabled, the transmitter outputs are turned off and all receiver outputs (ADM211E), receivers R1, R2, R3 (ADM213E) are placed in a high impedance state ...
Page 7
... LOAD CAPACITANCE – O –5 –10 – LOAD CURRENT – mA ADM206E/ADM207E/ADM208E/ADM211E/ADM213E 80 70 LIMIT START 30.0 MHz O –1 –3 –5 Tx O/P LO –7 – ...
Page 8
... ADM206E/ADM207E/ADM208E/ADM211E/ADM213E 350 300 V– 250 200 150 V+ 100 50 0 4.5 4.7 4.9 5.1 V – –5 V– –10 –15 5.3 5 LOAD CURRENT– mA ...
Page 9
... During shut- down the charge pump is also disabled. The shutdown control input is active high on the ADM211E, and it is active low on the ADM213E. When exiting shutdown, the charge pump is restarted and it takes approximately 100 µs for it to reach its steady state operating conditions ...
Page 10
... ADM206E/ADM207E/ADM208E/ADM211E/ADM213E High Baud Rate The ADM2xxE feature high slew rates permitting data transmis- sion at rates well in excess of the EIA-232-E specifications. RS-232 levels are maintained at data rates up to 230 kb/s even under worst case loading conditions. This allows for high-speed data links between two terminals, or indeed it is suitable for the new generation modem standards which require data rates of 200 kb/s. The slew rate is internally controlled to less than 30 V/µ ...
Page 11
... There are four levels of compliance defined by IEC1000-4-2. The ADM2xxE family of products meet the most stringent compliance level for both contact and for air-gap discharge. This means that the products are able to withstand contact discharges in excess and air-gap discharges in excess of 15 kV. ADM206E/ADM207E/ADM208E/ADM211E/ADM213E R2 DEVICE UNDER TEST Level ...
Page 12
... ADM206E/ADM207E/ADM208E/ADM211E/ADM213E Table VI. V Peak (kV) Level PSU 1 0 simplified circuit diagram of the actual EFT generator is illustrated in Figure 20. The transients are coupled onto the signal lines using an EFT coupling clamp. The clamp long and it completely sur- rounds the cable providing maximum coupling capacitance ( 200 pF typ) between the clamp and the cable ...
Page 13
... Conducted emissions are measured by monitoring the line power supply. The equipment used consists of a LISN (Line Impedance Stabilizing Network) which essentially presents a fixed impedance at RF, and a spectrum analyzer. The spectrum analyzer scans for emissions MHz and a plot for the ADM211E is shown in Figure 23 ...
Page 14
... ADM206E/ADM207E/ADM208E/ADM211E/ADM213E (5.33) 0.200 (5.05) 0.125 (3.18) PIN 1 0.0118 (0.30) 0.0040 (0.10) PIN 1 0.0118 (0.30) 0.0040 (0.10) OUTLINE DIMENSIONS Dimensions shown in inches and (mm). 24-Lead DIP (N-24) 1.275 (32.30) 1.125 (28.60 0.280 (7.11) 0.240 (6.10 PIN 1 0.060 (1.52) 0.015 (0.38) 0.210 0.150 MAX (3.81) MIN 0.100 0.022 (0.558) 0.070 (1.77) SEATING (2.54) PLANE 0.014 (0.356) 0.045 (1.15) BSC 24-Lead SOIC (R-24) ...
Page 15
... ADM206E/ADM207E/ADM208E/ADM211E/ADM213E OUTLINE DIMENSIONS Dimensions shown in inches and (mm). 24-Lead SSOP (RS-24) 0.328 (8.33) 0.318 (8.08 0.212 (5.38) 0.205 (5.21) 0.311 (7.9) 0.301 (7.64 PIN 1 0.078 (1.98) 0.015 (0.38) 0.07 (1.78) 0.068 (1.73) 0.010 (0.25) 0.066 (1.67) 0.0256 SEATING 0.009 (0.229) 0.008 (0.203) (0.65) PLANE 0.005 (0.127) 0.002 (0.050) BSC 28-Lead SSOP (RS-28) 0.407 (10.34) 0.397 (10.08 0.212 (5.38) ...
Page 16
... ADM206E/ADM207E/ADM208E/ADM211E/ADM213E PIN 1 0.006 (0.15) 0.002 (0.05) SEATING PLANE Revision History Location Changed from REV REV C. Features Change 460 kbits/s to 230 kbits Specifications Table Changed in Min, Typ, Max, Test Conditions/Comments columns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Absolute Maximum Ratings Deleted some items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Figures Change made in Figure Typical Performance Characteristics Changes made in plots ...