Product Highlights
The VI-200 family, with over 12 million units
shipped, is Vicor’s broad series of
“zero-current-switching” component-level
DC-DC converters.
Operating at frequencies up to 2 MHz, VI-200
family converters offer exceptional power
density, efficiency, noise performance,
reliability and ease of use. Booster modules
(VI-Bxx) provide a simple, cost-effective,
off-the-shelf solution for higher power output
requirements. One or more boosters may be
used to create synchronous arrays capable of
supplying several kilowatts of output power.
The flexibility of Vicor’s power components is
also available in half-size, half-power VI-J00
MiniMods.
Packaging Options
SlimMods™, high power density, flangeless
devices and FinMods™, featuring integral
finned heatsinks.
SlimMod: Option suffix: - S
Example: VI - 2XX - XX - S
FinMod: Option suffix: - F1, - F2, -F3 or -F4
Examples:
VI - 2XX - XX -F1, 0.25" fins, longitudinal
VI - 2XX - XX -F2, 0.50" fins, longitudinal
VI - 2XX - XX -F3, 0.25" fins, transverse
VI - 2XX - XX -F4, 0.50" fins, transverse
BusMod: Option suffix: -B1
MegaMod: VI - LXX - XX
Features
RoHS compliant (VE-200)
Up to 50 W/in
cULus, cTÜVus
Up to 90% efficiency
Size: 4.6" x 2.4" x 0.5"
(116,8 x 61,0 x 12,7mm)
Remote sense and current limit
OVP, thermal shutdown
Logic disable
Wide range output adjust
Compatible power booster modules
ZCS power architecture
Low noise FM control
CE Marked
3
Set your site on VICOR at www.vicorpower.com
Data Sheet
VI-200, VE-200
DC-DC Converters
50 to 200 Watts
Converter Selection Chart
[c]
[d]
[a]
V I -2
Nominal
W = 24 V
N = 48 V
V = 24 V
T = 110 V
0 = 12 V
1 = 24 V
2 = 36 V
3 = 48 V
4 = 72 V
5 = 150 V
6 = 300 V
7 = 150/300 V
E for RoHS compliant
Transient voltage for 1 second.
X,V, and T outputs are 50 W max.
W = 5.5 V
M = 10 V
Y = 3.3 V
X = 5.2 V
V = 5.8 V
R = 7.5 V
P = 13.8 V
Z = 2.0 V
T = 6.5 V
0 = 5.0 V
1 = 12 V
Input Voltage
Output Voltage
[b]
[a]
Maximum
Power
(1)
(2)
(3)
(4)
(5)
(6)
(7)
VI-200 DC-DC Converters 50 to 200 Watts
Input Range
100 – 200 V
200 – 400 V
100 – 375 V
Full Power
55 – 100 V
66 – 160 V
10 – 20 V
10 – 36 V
21 – 32 V
18 – 36 V
21 – 56 V
42 – 60 V
36 – 76 V
N = 18.5 V
K = 40 V
H = 52 V
D = 85 V
B = 95 V
L = 28 V
F = 72 V
2 = 15 V
3 = 24 V
J = 36 V
4 = 48 V
Outputs
150 W
100 W
200 W
150 W
75 W
75 W
50 W
5 V
Max Power
M = –55 to +85
C = –25 to +85
E = –10 to +85
(1)
(7)
(4)
(2)
(3)
(4)
(4)
(4)
(2)
(5)
(4)
(6)
I = –40 to +85
Product Grade Temperatures (°C)
Output Power/Current Vout
Operating
For additional output power use “Boosters”.
Y = 50 W
X = 75 W
W= 100 W
V = 150 W
U = 200 W
Outputs
Overtemperature shutdown 95°C typical
[b]
≥ 5 V
150 W
100 W
200 W
200 W
100 W
>5 V
75 W
75 W
Change (VI-2xx-xx) to (VI-Bxx-xx)
(recycle power to restart)
[d]
75% Max Power
Low Line
170
n/a
n/a
n/a
n/a
n/a
18
18
36
45
85
90
Rev. 2.4
M = –65 to +100
C = –40 to +100
E = –20 to +100
I = –55 to +100
Outputs
Y = 10 A
X = 15 A
W = 20 A
V = 30 A
U = 40 A
Storage
< 5 V
15 A
30 A
20 A
40 A
40 A
20 A
15 A
< 5 V
Transient
110 V
215 V
425 V
22 V
36 V
60 V
72 V
n/a
n/a
n/a
n/a
n/a
Page 1 of 5
[c]

Related parts for VE-263-CU

VE-263-CU Summary of contents

Page 1

... Example 2XX - FinMod: Option suffix: - F1, - F2, -F3 or -F4 Examples 2XX - XX -F1, 0.25" fins, longitudinal VI - 2XX - XX -F2, 0.50" fins, longitudinal VI - 2XX - XX -F3, 0.25" fins, transverse VI - 2XX - XX -F4, 0.50" fins, transverse BusMod: Option suffix: -B1 MegaMod LXX - XX Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Set your site on VICOR at www ...

Page 2

... VI-200 C-, I-, M-Grade Typ Max Min Typ 50 50 1000 1000 6 6 0.65 6 1.05 0.95 VI-200 DC-DC Converters 50 to 200 Watts Max Units Test Conditions -6 -6 200 x 10 Coulombs Nominal line I Nominal line, full load Vin dB 120 Hz, nominal line Vout ( ) Vin ...

Page 3

... VI-200 I-, M-Grade Typ Max Min Typ 6.3 6.4 7.2 7.3 (178) (181) (205) (208) VI-200 DC-DC Converters 50 to 200 Watts Max Units Test Conditions V Baseplate earthed RMS V RMS V RMS Max Units Test Conditions °C/Watt With Vicor P/N 20266 Cool and recycle power 105 °C ...

Page 4

... Standard Product ID .040 (1,0) Dia (7) places this surface Solder plate over copper alloy 4.20 .22 (106,7) (5,6) MIN .50 +.030 (0,76) (12,7) -.000 (0) VI-200 DC-DC Converters 50 to 200 Watts RoHS 0.080 (2,0) Dia (2) places Matte tin over copper alloy Pin # Function 1 +In 2 Gate In 3 Gate Out 4 -In 5 ...

Page 5

... Vicor does not assume any liability arising out of the application or use of any product or circuit; neither does it con- vey any license under its patent rights nor the rights of others. Vicor general policy does not recommend the use of its compo- nents in life support applications wherein a failure or malfunction may directly threaten life or injury. Per Vicor Terms and Conditions of Sale, the user of Vicor components in life support applications assumes all risks of such use and indemnifies Vicor against all damages ...

Related keywords