BMP25-40W Datel, Inc., BMP25-40W Datasheet - Page 3

no-image

BMP25-40W

Manufacturer Part Number
BMP25-40W
Description
Manufacturer
Datel, Inc.
Datasheet
2 5 - 4 0 W , D U A L
Performance/Functional Specifications
Typical @ T
Input Voltage Range:
Input Current
Input Filter Type
Overvoltage Shutdown:
Reverse-Polarity Protection
On/Off Control (Pin 5)
V
Temperature Coefficient
Ripple/Noise (20MHz BW)
Line/Load Regulation
Efficiency
Isolation Voltage
Isolation Capacitance
Current Limiting
Overvoltage Protection
Transient Response (50% load step)
Switching Frequency
Operating Temperature (ambient):
Storage Temperature
Dimensions
Shielding
Case Connection
Case Material
Pin Material
Weight
OUT
Q12 Models
D24 Models
Q48 Models
D48 Models
Q12 and D24 Models
Q48 and D48 Models
Without Derating
With Derating
Maximum Case Temperature
These converters require a minimum 10% loading on each output to maintain
specified regulation. Operation under no-load conditions will not damage these devices;
however they may not meet all listed specifications.
"Full load" varies by part number and is determined by the input voltage range as indicated by
the part number suffix. See Technical Notes and Output Power Considerations.
Application-specific input/output filtering can be recommended or perhaps added internally
upon request. Contact DATEL Applications Engineering for details.
Applying a voltage to the On/Off Control pin when no input power is applied to the converter
can cause permanent damage to the converter. If desired, the On/Off Control function can be
replaced with a Sync function. See page 6 of this data sheet for more details.
Listed specification is for input-to-output isolation. Input-to-case and output-to-case
isolation is 1000Vdc, minimum.
Accuracy (50% load)
A
= +25°C under nominal line voltage and "full-load" conditions, unless noted.
O U T P U T
Dynamic Characteristics
Environmental
Physical
Output
Input
40 Volts
80 Volts
±1%, maximum
300µsec max. to ±1.5% of final value
10-36 Volts (24V nominal)
18-36 Volts (24V nominal)
18-75 Volts (48V nominal)
36-75 Volts (48V nominal)
See Ordering Guide
Pi
Yes (Instantaneous, 6A maximum)
TTL high (or open) = on, low = off
±0.02% per °C
See Ordering Guide
See Ordering Guide
See Ordering Guide
1500Vdc, minimum
620pF
Continuous, auto-recovery
Zener/transorb clamps, magnetic feedback
125kHz (±10%)
–40 to +60°C (Model dependent)
to +90°C (See Derating Curves)
+90°C
–40 to +105°C
2.04" x 3.04" x 0.55" (51.8 x 77.2 x 14mm)
5-sided
Pin 4
Aluminum, black anodized finish
with plastic header
Brass, solder coated
6 ounces (170 grams)
D C / D C
C O N V E R T E R S
3
Floating Outputs
Since these are isolated DC/DC converters, their outputs are "floating." Any
BMP model may be configured to produce an output of 10V, 24V or 30V (for
±
+Output and –Output (pins 9 and 6), with either output grounded. The
Common (pin 8) should be left open. Minimum 20% loading is recom-
mended under these conditions. The total output voltage span may be
externally trimmed as described below.
Filtering and Noise Reduction
All BMP 25-40 Watt DC/DC Converters achieve their rated ripple and noise
specifications without the use of external input/output capacitors. In critical
applications, input/output ripple and noise may be further reduced by
installing electrolytic capacitors across the input terminals and/or low-ESR
tantalum or electrolytic capacitors across the output terminals. Output
capacitors should be connected between their respective output pin (pin 6 or
9) and Common (pin 8). See Figure 7. The caps should be located as close
to the converters as possible. Typical values are listed in the below. In many
applications, using values greater than those listed will yield better results.
In critical, space-sensitive applications, DATEL may be able to tailor the
internal input/output filtering of these devices to meet your specific require-
ments. Contact our Applications Engineering Group for additional details.
Input Fusing
5V,
T E C H N I C A L N O T E S
These are stress ratings. Exposure of devices to any of these conditions may adversely
affect long-term reliability. Proper operation under conditions other than those listed in the
Performance/Functional Specifications Table is not implied.
Input Voltage:
Input Reverse-Polarity Protection
Output Overvoltage Protection
Output Current
Storage Temperature
Lead Temperature (soldering, 10 sec.)
To Reduce Input Ripple
To Reduce Output Ripple
V
Fuse Value
±
IN
12V or
Q12/D24 Models
Q48/D48 Models
±5V Outputs
±12V Outputs
±15V Outputs
Range
"Q12, D24" Models
"Q48, D48" Models
±5V Outputs
±12/15V Outputs
±
15V models, respectively) by applying the load across the
Q12
4A
Absolute Maximum Ratings
D24
4A
47µF, 50V
10µF, 100V
47µF, 10V, Low ESR
22µF, 20V, Low ESR
44 Volts
88 Volts
Current must be <6A. Brief
duration only. Fusing recommended.
6.8 Volts, limited duration
15 Volts, limited duration
18 Volts, limited duration
Current limited. Max. current and
short-circuit duration are model
dependent.
–40 to +105°C
+300°C
Q48
3A
D48
BMP Models
2A

Related parts for BMP25-40W