MPC89L515A Megawin Technology, MPC89L515A Datasheet - Page 24

no-image

MPC89L515A

Manufacturer Part Number
MPC89L515A
Description
8-bit micro-controller
Manufacturer
Megawin Technology
Datasheet
www.DataSheet4U.com
Mode2
An 11-bit data is serially transmitted through TXD or received through RXD. The frame data
includes a start bit (0), 8 data bits, a programmable 9th bit and a stop bit (1). On transmit, the 9th
data bit comes from TB8 in SFR SCON. On receive, the 9th data bit goes into RB8 in SCON. The
baud rate is programmable, and permitted to be set either 1/32 or 1/64 the oscillator frequency.
Mode3
Mode 3 is the same as mode 2 except the baud rate is variable.
In all four modes, transmission is initiated by any instruction that uses SBUF as a destination
register. Reception is initiated in mode 0 by the condition RI = 0 and REN = 1. Reception is initiated
in the other modes by the incoming start bit with 1-to-0 transition if REN=1.
There are several SFR related to serial port configuration described as following.
SFR: SCON (Serial Port Control):
{ SM0, SM1 }: Used to set operating mode of the serial port. It is enabled to access by clearing SMOD0.
FE: Frame Error bit. This bit is set by the receiver when an invalid stop bit is detected. The FE bit is not cleared
24
SM0/FE
Bit-7
by valid frames, but should be cleared by software. The SMOD0 (PCON.6) bit must be set to enable
access to the FE bit.
{ 0, 0 } := set the serial port operate under Mode 0
{ 0, 1 } := set the serial port operate under Mode 1
{ 1, 0 } := set the serial port operate under Mode 2
{ 1, 1 } := set the serial port operate under Mode 3
Bit-6
SM1
Baud Rate (for Mode 3)
Baud Rate (for Mode 2)
Bit-5
SM2
or =
MPC89x515A Data Sheet
=
Bit-4
REN
=
(Timer-2 overflow rate)
2
SMOD
32
2
Bit-3
TB8
16
64
SMOD
X
(Timer-1 overflow rate)
Bit-2
RB8
X F
osc
Bit-1
TI
Bit-0
RI
MEGAWIN