ADC1061 National Semiconductor, ADC1061 Datasheet
ADC1061
Available stocks
Related parts for ADC1061
ADC1061 Summary of contents
Page 1
... A/D without the cost, power dissipation, and other problems associated with true flash approaches. The analog input voltage to the ADC1061 is tracked and held by an internal sampling circuit. Input signals at frequencies from DC to greater than 160 kHz can therefore be digitized accurately without the need for an external sample-and-hold circuit ...
Page 2
... RD (4) This is the active low Read control input. When this pin is low, any data present in the ADC1061’s output registers will be placed on the data bus. In Mode 2, the Read signal must be low until INT goes low. Until INT goes low, the data at the output pins will be incorrect ...
Page 3
... Infrared (15 seconds) Junction Temperature, T −0.3V to +6V Storage Temperature Range + −0. +0. Operating Ratings 20 mA 875 mW Temperature Range 1500V ADC1061CIN, ADC1061CIWM Supply Voltage Range 260˚C = 5V, and V = GND unless otherwise specified. Boldface lim- REF(+) REF(− 25˚ Conditions Typical (Note 7) ± ...
Page 4
AC Electrical Characteristics + The following specifications apply for Boldface limits apply for MIN Symbol Parameter t Conversion Time from Rising Edge CONV Falling Edge of INT t ...
Page 5
TRI-STATE Test Circuits and Waveforms DS010559-5 Timing Diagrams FIGURE 1. Mode 1. The conversion time (t FIGURE 2. Mode 2 (RD Mode). The conversion time (t the sampling time, and is determined by the internal timer. (Continued) DS010559-6 DS010559-7 ) ...
Page 6
... Reference Voltage Mode 1 Conversion Time vs Temperature Functional Description The ADC1061 digitizes an analog input signal to 10 bits ac- curacy by performing two lower-resolution “flash” conver- sions. The first flash conversion provides the six most signifi- cant bits (MSBs) of data, and the second flash conversion provides the four least significant bits (LSBs) ...
Page 7
... In Mode 2, also called “RD mode”, the S /H and RD pins are tied together. A conversion is initiated by pulling both pins low. The ADC1061 samples the input voltage and causes the coarse comparators to become active. An internal timer then terminates the coarse conversion and begins the fine con- version. About 1.8 µ ...
Page 8
... ADC1061. 4.0 Inherent Sample-and-Hold Because the ADC1061 samples the input signal once during each conversion capable of measuring relatively fast in- put signals without the help of an external sample-hold conventional successive-approximation A/D converter, re- ...
Page 9
... CC CC these voltage limits are exceeded, the overdrive current into or out of any pin on the ADC1061 must be limited to less than 5 mA, and no more than overdrive current (all overdriven pins combined) should flow. In systems with mul- tiple power supplies, this may require careful attention to power supply sequencing. The ADC1061’ ...
Page 10
... Physical Dimensions inches (millimeters) unless otherwise noted www.national.com Order Number ADC1061CIWM NS Package Number M20B Order Number ADC1061CIN NS Package Number N20A 10 ...
Page 11
... NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF NATIONAL SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant ...