TS6601H ETC, TS6601H Datasheet - Page 5

no-image

TS6601H

Manufacturer Part Number
TS6601H
Description
Tact Switch Series (6x6mm)
Manufacturer
ETC
Datasheet
6.3.1.
6.3.2.
6.3.3.
6.3 Environmental
Resistance to
Low
Temperatures
Heat
Resistance
Moisture
Resistance
6.3.4.
Temperature
Cycling
Item
Following the test set forth below the sample shall be
left in normal temperature and humidity conditions
for one hour before measurements are made:
(1)Temperature: -30±2°C
(2)
(3)Water drops shall be removed.
Following the test set forth below the sample shall be
left in normal temperature and humidity conditions
for one hour before measurements are made:
(1)Temperature: 80±2°C
(2)
Following the test set forth below the sample shall be
left in normal temperature and humidity conditions
for one hour before measurements are made:
(1)
(2)Relative humidity: 90 to 95%
(3)
(4)Water drops shall be removed.
Following five cycles of the temperature cycling test
set forth below the sample shall be left in normal
temperature and humidity conditions for one hour
before measurements are made.
During this test, water drops shall be removed.
TACTING SWITCH SPECIFICATION
+60℃
-10℃
Temperature: 60±2°C
Time: 96 hours
Time: 96 hours
2 H
Time: 96 hours
Test Conditions
1 cycle
1H
2 H
1H
PART NO:
Contact resistance:
Insulation resistance:
Requirements
200 m ohm max.
Item 6.1
Item 6.2.1
Item 6.2.2
Item 6.1
Item 6.2.1
Item 6.2.2
10
Item 6.1.3
Item 6.1.4
Item 6.2.1
Item 6.2.2
Item 6.1
Item 6.2.1
Item 6.2.2
TS6601H
M ohm min.
4/6