PC-414A ETC, PC-414A Datasheet

no-image

PC-414A

Manufacturer Part Number
PC-414A
Description
Last Time Buy Notice Board Products
Manufacturer
ETC
Datasheet
Last Time Buy Notice – Board Products
November 7, 2003
Effective immediately, DATEL, Inc. will be phasing out its line of board-level data acquisition
products. We will accept last time buy orders until February 28, 2004. Final shipments must
be accepted by June 31, 2004. In addition, all repairs and technical support must be concluded
by September 30, 2004. Please contact DATEL Sales as soon as practical to schedule your
order.
If this Notice is received by Purchasing, Materiel or Procurement personnel, we strongly
encourage you to forward this to your Engineering, Administrative and Program colleagues as
soon as practical.
Models to be Discontinued - Essentially all DATEL board-level data acquisition products, all
board-level accessories and all board software are covered in this Notice. This includes:
All ST-xxx model numbers (Multibus I boards, example ST-711)
All PC-xxx model numbers (ISA bus boards, example PC-414)
All DVME-xxx model numbers (VME bus boards, example DVME-628)
All CPCI-xxx model numbers (Compact PCI bus boards, example CPCI-511)
All PCI-xxx model numbers (PCI bus boards, example PCI-416)
Please note that many older ST-xxx, DVME-xxx and PC-xxx boards are already on very
limited availability due to component obsolescence and other manufacturing issues.
Last Time Orders - Customers should contact the DATEL Sales Dept. (Mansfield, MA, USA)
directly to place orders and negotiate delivery schedules. Some products may require minimum
order quantities and/or extended delivery. This varies over time so it is difficult to give an exact
list of such products.
To assure supply, we encourage customers to accept deliveries as soon as practical. As
time passes, customers risk non-availability of an increasing number of products. After the
customer accepts final order acknowledgement, all orders placed will be firm and non-
cancellable.

Related parts for PC-414A

PC-414A Summary of contents

Page 1

... All CPCI-xxx model numbers (Compact PCI bus boards, example CPCI-511) All PCI-xxx model numbers (PCI bus boards, example PCI-416) Please note that many older ST-xxx, DVME-xxx and PC-xxx boards are already on very limited availability due to component obsolescence and other manufacturing issues. ...

Page 2

Warranty - DATEL’s standard warranty terms apply except the warranty period. As the date of last shipments approach, warranty support and repairs will terminate on September 30, 2004. Customers must immediately perform a functional inspection on any shipments near this ...

Page 3

... V, or bipolar ± ±10 V depending on the model. Model PC-414E offers 16 single-ended or 8 differential high speed channels. Models PC-414F and P include a simultaneous sampling section. This function acquires signals on parallel channels at the same time. This prevents phase errors and skewing of multichannel correlated signals ...

Page 4

... D/A converter. If preferred, the D/A converter may also be used as a general purpose analog output channel. The PC-414B and P versions contain five SMA coaxial signal connectors. Four connectors are for the sampled analog channels. The fifth connector is used for external timebase clock input, external analog trigger signal, or for the analog output ...

Page 5

... Throughput to FIFO (sequential channels, gain = 1) Total Harmonic Distortion [Note 3] The PC-414J in short-cycled addressing is recommended in place of the PC-414A. Model PC-414E can substitute for the PC-414C. ANALOG INPUTS Programmable Gains See Note 1 Common Mode Rejection ( Hz) - 100) (414E) Addressing Modes 1 ...

Page 6

... MHz 10 MHz 1 MHz/chan. (2 chans.) — –80 dB – ® PC-414J PC-414K 8 Simultaneous A/D’s 2 Simultaneous [Note 8] (two A/D’s) Single Ended Limited Differential ±5 V, ± +10 V, ±5 V [Note 13] (separate models) ±15 V ± µs — — ...

Page 7

... The sample rate to published specifications is 3 MHz. The A/D is functional to 5 MHz. Valid data output per channel is delayed by 4 samples after the start of the sample clock. Please make note of this for products such as the PC-414P, PC-430P, and DVME-614P which use non-continuous A/D sampling. Data output is pipelined meaning that the first four samples per channel should be discarded ...

Page 8

... MISCELLANEOUS Analog Section Modularity The MUX-S/H-A/D module is socketed for function interchange. Analog Section Adjustments Offset and gain per channel for SSH on PC-414F and P. A single offset and gain pot is provided on PC-414B, D, and E. Recommended recalibration interval is 90 days in stable conditions. ...

Page 9

... PC-414G acquisition time is 350 ns to ±0.01% of FSR. 12. All channels in simultaneous sampling. 13. PC-414J and L bipolar input is user-selectable ± ±10 V per channel (default). Total full scale error over temperature range is ±4 LSB maximum. Total zero/offset error over temperature range is ±2 LSB maximum. ...

Page 10

... Internal or external trigger rate Internal or external start rate Fixed or sequential channel addressing up to 64k samples per trigger HOLD Maskable Interrupt and Status Figure 4. PC-414 Timing DIagram 86 ® Binary A/D Data See model PC-414COM using a DSP COMM Parallel port interface. Port Array Processor ...

Page 11

... For users preferring to create applications in Visual Basic, the DLL and source code found in the PC-414LVS offers the Visual Basic programmer a wealth of information and tools in creating applications quickly and easily. The PC-414VB-CONSOLE is a sample program showing how to implement most of the functions of the PC-414 Series. Included is the source code for all the forms and the code modules. ...

Page 12

... VI’s or just wants to more fully understand their operation. LabVIEW’s feature-rich program development system combined with DATEL’s library of VI functions for the PC-414 provide the essential building blocks to create any conceivable LabVIEW applications. ...

Page 13

... Windows applications without disrupting PC-414 operation or control. The PC-414/LabVIEW system optimizes two concurrent processes - the PC-414 acquiring data while LabVIEW further processes or stores the uploaded data stream. The entire PC-414/LabVIEW combination uses only a few VI functions that are easy to understand and incorporate into a “block diagram” ...

Page 14

... Setup/configuration program for Microsoft Windows NT. Executables only. PC-414NTS Source code for PC-414NT, written with Borland Delphi. Call DATEL Free example programs for the PC-414, written in Visual Basic 5. Contact Systems Application Dept. Call DATEL Free example programs for the PC-414, written in Microsoft QuickBASIC. Contact System Application Dept. ...

Related keywords