MB3889 Fujitsu Microelectronics, Inc., MB3889 Datasheet - Page 15

no-image

MB3889

Manufacturer Part Number
MB3889
Description
2-channel Dc/dc Converter Ic With Overcurrent Protection Symmetrical-phase Type
Manufacturer
Fujitsu Microelectronics, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MB3889
Quantity:
178
Part Number:
MB3889
Manufacturer:
FUJITSU/富士通
Quantity:
20 000
Part Number:
MB3889PFT
Manufacturer:
INFINEON
Quantity:
320
Part Number:
MB3889PFT
Manufacturer:
FUJI
Quantity:
1 000
Part Number:
MB3889PFT
Manufacturer:
FUJI/富士电机
Quantity:
20 000
Part Number:
MB3889PFT-G-BND-ER
Manufacturer:
FUJITSU
Quantity:
2 000
Part Number:
MB3889PFT-G-BND-ERE1
Manufacturer:
TI
Quantity:
421
2. Channel Control Function
*: Undefined
3. Protective Functions
(1) Undervoltage lockout protection circuit (UVLO)
(2) Timer-latch overcurrent protection circuit block (OCP)
(3) Timer-latch short-circuit protection circuit (SCP)
Channels, main, VB and PWRGOOD are turned on and off depending on the voltage levels at the CTL terminal
(pin 6), CTL1 terminal (pin 9) and CTL2 terminal (pin 10).
The transient state or a momentary drops in supply voltage, which occurs when the power supply is turned on,
may cause the control IC to malfunction, resulting in breakdown or degradation of the system. To prevent such
malfunctions, the undervoltage lockout protection circuit detects the internal reference voltage level with respect
to the power supply voltage, turns off the output transistor, and sets the dead time to 100% while holding the
CSCP terminal (pin 11) at the “L” level and setting the PWRGOOD terminal (pin 12) to the “L” level.
The system is restored when the supply voltage reaches the threshold voltage of the undervoltage lockout
protection circuit.
The timer-latch overcurrent protection circuit is actuated upon completion of the soft-start period. When an
overcurrent flows, the circuit detects the increase in the voltage between the main-side FET’s drain and source
using the main-side FET ON resistor, actuates the timer circuit, and starts charging the capacitor CSCP con-
nected to the CSCP terminal (pin 11). If the overcurrent remains flowing beyond the predetermined period of
time, the circuit sets the latch to turn off the FETs on the main side and synchronous rectification side of each
channel while setting the PWRGOOD terminal (pin 12) to the “L” level. The detection current value can be set
by resistor RLIM1 connected between the main-side FET’s drain and the ILIM1 terminal (pin 25) and resistor
RLIM2 connected between the drain and the ILIM2 terminal (pin 23).
To reset the actuated protection circuit, either the power supply turn off and on again or set the CTL terminal
(pin 6) to the “L” level to lower the VREF terminal (pin 8) voltage to 1.7 V (Min) or less. It can also be reset by
setting both of the CTL1 terminal (pin 9) and CTL2 terminal (pin 10) to the “L” level. (See “1. Setting Timer-Latch
Overcurrent Protection Detection Current” in
The short-circuit detection comparator (SCP Comp.) provided for the two channels detects the output voltage
level and, if the error amplifier output voltage of either channel reaches the short-circuit detection voltage (typically
3.1 V), the timer circuit is actuated to start charging the external capacitor Cscp connected to the CSCP terminal
(pin 11).
When the capacitor voltage reaches about 0.7 V, the circuit turns off the output transistor and sets the dead time
to 100%.
The PWRGOOD terminal (pin 12) is fixed at the “L” level.
To reset the actuated protection circuit, either the power supply turn off and on again or set the CTL terminal
(pin 6) to the “L” level to lower the VREF terminal (pin 8) voltage to 1.7 V (Min) or less. It can also be reset by
setting both of the CTL1 terminal (pin 9) and CTL2 terminal (pin 10) to the “L” level. (See “2. Setting Time
Constant for Timer-Latch Short-Circuit Protection Circuit” in
CTL
H
H
H
H
L
CTL1
H
H
L
L
*
CTL2
H
H
L
L
*
Channel On/Off Setting Conditions
Power
OFF
ON
ON
ON
ON
ABOUT TIMER-LATCH PROTECTION CIRCUIT.)
CH1
OFF
OFF
OFF
ON
ON
ABOUT TIMER-LATCH PROTECTION CIRCUIT.)
CH2
OFF
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
VB
MB3889
PWRGOOD
OFF
ON
ON
ON
ON
15

Related parts for MB3889