SF4-DC48V Matsushita Electric Works(Nais), SF4-DC48V Datasheet
SF4-DC48V
Available stocks
Related parts for SF4-DC48V
SF4-DC48V Summary of contents
Page 1
... Contact arrangement 2: 2 Form A 2 Form 12, 18, 21 Form A 1 Form B 24, 36, 48 Form A 4 Form B UL/CSA, TÜV, SEV approved type is standard (SF2, SF4) TÜV approved type is standard (SF3) 258 POLARISED, MONOSTABLE SAFETY RELAY with (mechanical linked) forced ...
Page 2
... SF2-DC48V 48 SF2-DC60V 60 SF3-DC5V 5 SF3-DC9V 9 SF3-DC12V 12 SF3-DC18V 18 SF3 SF3-DC21V 21 SF3-DC24V 24 SF3-DC36V 36 SF3-DC48V 48 SF3-DC60V 60 SF4-DC5V 5 SF4-DC9V 9 SF4-DC12V 12 SF4-DC18V 18 SF4 SF4-DC21V 21 SF4-DC24V 24 SF4-DC36V 36 SF4-DC48V 48 SF4-DC60V 60 DIMENSIONS 1) SF2 25.0 .984 7.62 .300 Pick-up Drop-out Coil voltage, VDC voltage resistance (max.) (min.) ( 10%) 3.75 0.5 50 6.75 0.9 9 1.2 288 13.5 1.8 15.75 2.1 14.4 2.4 1.152 27 3.6 36 4.8 4.608 45 6 ...
Page 3
... PC board pattern (Bottom view) 18-1.4 DIA. HOLES 2.54 18-.055 DIA. HOLES .100 2.54 .100 Tolerance: 0.1 ±.004 3. Ambient temperature characteristics Tested sample: SF4-DC12V Quantity 100 Drop-out voltage 50 Pick-up voltage -40 - Ambient temperature, C -50 -100 inch ...
Page 4
SAFETY STRUCTURE OF SF RELAYS This SF relay design ensures that subsequent operations shut down and can automatically return to a safe state when the SF relay suffers overloading and other circuit abnormalities (unforeseen 1. Forced operation method (2a2b, 3a1b, ...
Page 5
SF THE OPERATION OF SF RELAYS (when contacts are welded) SF relays work to maintain a normal operating state even when overloading or short-circuit currents occur also easy to include weld detection circuits and safety circuits in the ...
Page 6
Type Form “b” Contact Weld If the form “b” contact (No. 3) welds, the armature becomes non-operational, the contact gaps at the three form “a” contacts are maintained at greater than 0.5 mm .020 No.4 No.1 No.3 No.2 ...
Page 7
SF 3) 4a4b Type Internal Contacts Weld If the internal contacts (nos and 7) weld, the armature becomes non-operational and the contact gaps of each of the four form “a” contacts are maintained at greater than 0.5 ...