ltc4259a Linear Technology Corporation, ltc4259a Datasheet - Page 18

no-image

ltc4259a

Manufacturer Part Number
ltc4259a
Description
Quad Ieee 802.3af Power Over Ethernet Controller With Ac Disconnect
Manufacturer
Linear Technology Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ltc4259aCGW
Manufacturer:
LT/凌特
Quantity:
20 000
Part Number:
ltc4259aCGW#TR
Manufacturer:
LINEAR
Quantity:
45 308
Part Number:
ltc4259aCGW#TR
Manufacturer:
ROHM
Quantity:
4 942
Company:
Part Number:
ltc4259aCGW#TRPBF
Quantity:
5 100
Part Number:
ltc4259aCGW-1
Manufacturer:
LT
Quantity:
39 000
Part Number:
ltc4259aCGW-1
Manufacturer:
MURATA
Quantity:
3 942
Part Number:
ltc4259aCGW-1
Manufacturer:
LT
Quantity:
20 000
Part Number:
ltc4259aCGW-1 TR
Quantity:
5 700
Part Number:
ltc4259aCGW-1#
Manufacturer:
LT
Quantity:
20 000
Part Number:
ltc4259aCGW-1#TRPBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
ltc4259aIGW-1#PBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
APPLICATIO S I FOR ATIO
LTC4259A
Dual-Level Current Limit
A PD is permitted to draw up to 15.4W continuously and
up to 400mA for 50ms. The LTC4259A has two correspond-
ing current limit thresholds, I
(425mA typ). These are given by the equations:
R
802.3af compliance. While the LTC4259A allows the port
current to exceed I
timing below), it does not allow the current to exceed I
The current limit circuit monitors the port current by
monitoring the voltage across the sense resistor and re-
duces the MOSFET gate voltage as needed to keep the
current at or below I
I
the MOSFET resistance to a minimum.
t
Whenever more than I
the port’s sense voltage is above V
counts up. The t
OUT pin voltage is above V
persists and the t
off power to the port immediately and set the appropriate
t
programmed via register 16h, bits 2 and 3 (Table 1).
The t
protect the external MOSFET from thermal stress caused
by repeatedly operating in current limit. The counter
counts up whenever the current is above I
down at 1/16th the rate when it is not. The counter will
bottom out at zero to prevent underflow. Full count indi-
cates that the t
turned off.
This count up/count down behavior implements duty cycle
protection, preventing intermittent current limit faults from
causing cumulative thermal stress in the MOSFET. If the port
enters current limit but then exits before the timer expires,
the count will decrease slowly, giving the I
ability to turn off sooner in the case of a repetitive fault. If
the overcurrent duty cycle is less than 6.3% the t
will be fully reset.
18
ICUT
ICUT
LIM
S
I
CUT
is the sense resistor and should be 0.5Ω for IEEE
, the gate voltage is restored to the full value to keep
ICUT
fault bit in register 06h/07h. The t
Timing
= V
timer is an up/down counter that is designed to
CUT
/R
ICUT
ICUT
S
ICUT
, I
CUT
U
timer has expired and the port will be
LIM
timer also counts up when the port’s
timer expires, the LTC4259A will turn
LIM
CUT
for a limited time period (see t
= V
. When the current drops below
U
= V
PG
LIM
. If either of these conditions
CUT
/R
CUT
/R
S
CUT
(375mA typ) and I
S
W
flows through a port,
ICUT
and the t
duration can be
CUT
CUT
and counts
U
ICUT
ICUT
timer the
timer
timer
ICUT
LIM
LIM
.
If the t
timer will continue to run, counting down at the slow
1/16th rate and preventing the port from being repowered
until the count returns to zero. This protects the MOSFET
from damage due to a faulty PD that may still have a valid
signature, or from errant software that repeatedly writes to
the Power On bit.
The port will not repower until after the t
returns to zero. In manual and semiauto modes the power
enable command must be received after the t
reaches zero. In auto mode the LTC4259A must complete
a valid detection cycle after the t
t
To distinguish between normal turn-on current limit be-
havior and current limit faults which occur after power-up
is complete, the LTC4259A starts a timer (the t
whenever a power-up sequence begins.
The t
most, it allows the user to specify a different current limit
timeout (t
limit duty cycle protection remains functional). Second,
the DC disconnect timer is disabled during this period and
can only begin counting up after the t
expired. Together, these two features let the PD draw the
maximum current I
boot up and begin drawing power without triggering a
t
entire t
instead of a t
the cause of an overcurrent fault.
As long as the PD draws less than I
and begins drawing the minimum current within t
t
be indicated.
The t
tion described under t
programmed via register 16h, bits 5 and 4 (Table 1).
START
START
START
START
START
ICUT
fault. Finally, if the device is in current limit for the
expires (if DC disconnect is enabled), no faults will
Timing
START
START
timer expires and causes the port to shut off, the
timer also implements the duty cycle protec-
timer serves three functions. First and fore-
ICUT
period, a t
instead of t
fault. This can be useful for tracking down
INRUSH
ICUT
START
to charge its input capacitance,
timing and its duration can be
ICUT
ICUT
) during turn-on (current
fault will be generated
CUT
counter reaches zero.
at the end of t
START
ICUT
ICUT
START
timer has
DIS
counter
counter
timer)
START
4259afb