sy89229u Micrel Semiconductor, sy89229u Datasheet

no-image

sy89229u

Manufacturer Part Number
sy89229u
Description
Sy89229u 1ghz Precision, Lvds ? 3, ? 5 Clock Divider With Fail-safe Input And Internal Termination
Manufacturer
Micrel Semiconductor
Datasheet
General Description
The SY89229U is a precision, low jitter 1GHz ÷3, ÷5
clock divider with an LVDS output. A unique Fail-
Safe Input (FSI) protection prevents metastable
output conditions when the input clock voltage swing
drops significantly below 100mV or input is removed.
The differential input includes Micrel’s unique, 3-pin
internal termination architecture that allows the input
to interface to any differential signal (AC- or DC-
coupled) as small as 100mV (200mV
level shifting or termination resistor networks in the
signal path. The outputs are 325mV, 100K-
compatible LVDS with fast rise/fall times guaranteed
to be less than 220ps.
The SY89229U operates from a 2.5V ±5% supply
and
temperature range of –40°C to +85°C. The
SY89229U is part of Micrel’s high-speed, Precision
Edge
All support documentation can be found on Micrel’s
web site at: www.micrel.com.
Block Diagram
August 2007
Precision Edge is a registered trademark of Micrel, Inc.
MLF and MicroLeadFrame are registered trademarks of Amkor Technology.
Micrel Inc. • 2180 Fortune Drive • San Jose, CA 95131 • USA • tel +1 (408) 944-0800 • fax + 1 (408) 474-1000 • http://www.micrel.com
®
is
product line.
guaranteed
over
the
PP
full
) without any
industrial
with Fail Safe Input and Internal Termination
1GHz Precision, LVDS ÷ ÷ ÷ ÷ 3, ÷ ÷ ÷ ÷ 5 Clock Divider
Features
• Accepts a high-speed input and provides a precision
• Fail-Safe Input
• Guaranteed AC performance over temperature and
• Ultra-low jitter design:
• Unique patented internal termination and VT pin
• Wide input voltage range VCC to GND
• 325mV LVDS output
• 46% to 54% Duty Cycle(÷ 3)
• 47% to 53% Duty Cycle(÷ 5)
• 2.5V ±5% supply voltage
• -40°C to +85°C industrial temperature range
• Available in 16-pin (3mm x 3mm) MLF
Applications
• Fail-safe clock protection
Markets
• LAN/WAN
• Enterprise servers
• ATE
• Test and measurement
÷3 and ÷5 sub-rate, LVDS output
supply voltage:
– DC-to >1.0GHz throughput
– <1500ps Propagation Delay (In-to-Q)
– <1ps
– <1ps
– <10ps
– <0.7ps
accepts DC- and AC-coupled inputs (CML, PECL,
LVDS)
– <220ps Rise/Fall times
Prevents oscillations when input is invalid
RMS
RMS
PP
RMS
total jitter (clock)
random jitter
cycle-to-cycle jitter
MUX crosstalk induced jitter
SY89229U
hbwhelp@micrel.com
or (408) 955-1690
M9999-080707-A
Precision Edge
®
package
®

Related parts for sy89229u

sy89229u Summary of contents

Page 1

... General Description The SY89229U is a precision, low jitter 1GHz ÷3, ÷5 clock divider with an LVDS output. A unique Fail- Safe Input (FSI) protection prevents metastable output conditions when the input clock voltage swing drops significantly below 100mV or input is removed. The differential input includes Micrel’s unique, 3-pin ...

Page 2

... Ordering Information Part Number Package SY89229UMG MLF-16 (2) SY89229UMGTR MLF-16 Notes: 1. Contact factory for die availability. Dice are guaranteed Tape and Reel. Pin Configuration August 2007 Operating Type Range Industrial Industrial = 25°C, DC Electricals Only. A ® 16-Pin MLF (MLF-16) 2 Package Marking Finish ...

Page 3

Pin Description Pin Number Pin Name 1, 4 IN, / VREF- / VCC 12 GND, 10, 11, 14,15 Exposed Pad 16 DIV_SEL Truth Table August 2007 Pin ...

Page 4

Absolute Maximum Ratings Supply Voltage (V ) ..........................–0.5V to +4.0V CC Input Voltage (V ) ..................................–0. LVDS Output Current (I )………………….±10mA OUT Current ( Source or sink current Input Current Source or ...

Page 5

LVDS Outputs DC Electrical Characteristics V = +2.5V ±5 100 across the outputs Symbol Parameter V Output Voltage Swing OUT (Q, /Q) V Differential Output Voltage Swing DIFF_OUT |Q – /Q| V Output Common Mode ...

Page 6

AC Electrical Characteristics V = 2.5V ±5 100 across the outputs Symbol Parameter f Maximum Input Operating MAX Frequency tw Minimum Pulse Width t Differential Propagation Delay pd In-to-Q In-to-Q /MR(H-L)-to-Q t Reset Recovery Time ...

Page 7

... PK PP Maximum frequency of the SY89229U is limited by the FSI function. Refer to Figure 1b. Input Clock Failure Case If the input clock fails to a floating, static, or extremely low signal swing, the FSI function will eliminate a metastable condition and guarantee a stable output signal. No ringing and no undetermined state will occur at the output under these conditions ...

Page 8

Timing Diagrams August 2007 Figure 1a. Propagation Delay Figure 1b. Fail Safe Feature 8 M9999-080707-A hbwhelp@micrel.com or (408) 955-1690 ...

Page 9

Figure 1c. Enable Output Timing Diagram Examples (Divide by 3) August 2007 9 hbwhelp@micrel.com M9999-080707-A or (408) 955-1690 ...

Page 10

August 2007 Figure 1d. Divider Operation Timing Diagram 10 M9999-080707-A hbwhelp@micrel.com or (408) 955-1690 ...

Page 11

Typical Operating Characteristics V = 2.5V, GND = 0V 200mV August 2007 / t ” 300ps 100 across the outputs 25°C, unless otherwise stated. A M9999-080707-A hbwhelp@micrel.com ...

Page 12

Functional Characteristics V =2.5V, GND = 0V 100mV Divide stated. August 2007 /t ” 300ps 100 across the outputs hbwhelp@micrel.com = 25°C, unless otherwise ...

Page 13

Single-Ended and Differential Swings Figure 2a. Single-Ended Voltage Swing Input Stage August 2007 Figure 3. Simplified Differential Input Stage 13 Figure 2b. Differential Voltage Swing M9999-080707-A hbwhelp@micrel.com or (408) 955-1690 ...

Page 14

Input Interface Applications Figure 4a. LVPECL Interface (DC-Coupled) Figure 4d. CML Interface (AC-Coupled) August 2007 Figure 4b. LVPECL Interface (AC-Coupled) Figure 4e. LVDS Interface (DC-Coupled) 14 Option: may connect Figure 4c. CML Interface (DC-Coupled) M9999-080707-A ...

Page 15

... SY89230U 3.2GHz Precision, LVPECL ÷3, ÷5 Clock Divider SY89231U 3.2GHz Precision, LVDS ÷3, ÷5 Clock Divider ® MLF Application Note August 2007 Figure 5b. LVDS Common Mode Measurement Datasheet Link http://www.micrel.com/_PDF/HBW/sy89228u.pdf http://www.micrel.com/_PDF/HBW/sy89230u.pdf http://www.micrel.com/_PDF/HBW/sy89231u.pdf www.amkor.com/products/notes_papers/MLFAppNote.pdf 15 hbwhelp@micrel.com SY89229U M9999-080707-A or (408) 955-1690 ...

Page 16

Package Information Packages Notes: 1. Package meets Level 2 Moisture Sensitivity Classification. 2. All parts are dry-packed before shipment. 3. Exposed pad must be soldered to a ground for proper thermal management. MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA ...